HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Fabric OS V4.2.x Rele - Page 23
Recommended Use the command port, to enable the, trunk for each port.
![]() |
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Issues and Workarounds Table 6: Issues and Workarounds (Continued) Issue Running the supportshow command on both the logical switches results in an Out Of Memory condition; the zoning daemon terminates NoNodeWWNZoning: The cfgenable command does not activate the feature. Post2 txdpath failed on blades with empty ports (no sfp). When changing interop modes and switching between interop and native mode, an fspfd core dump may occur. This is caused by clearing an element in a data structure beyond the allocated size. When configdownload succeeds on zoneDB, but fails on sec policy, the primary fails to propagate zoneDB to the fabric. The time stamp for firmware download from Fabric Manager-Web Tools is off by 8 hours, compared to the time on the switch. SwitchCfgTrunk leaves ports disabled, if a long distance port is configured on the switch. Immediately after activating SCC policy, the retrieve sec policy through API fails. An error is returned in a large fabric with more than 26 switches. This occurs when you use the Fabric Access API to remove multiple FCS members without first performing a save operation. Setting fcpprobedisable also sets fanFrameDisable Workaround Do not run the supportshow command on both logical switches at the same time. Instead of issuing the cfgenable command, first issue the cfgdisable command and then cfgenable. Note that this defect affects the running of diagnostics only on ports that do not have an SFP installed. You can either install an SFP in all ports or use the port list to specify only those ports with an SFP. Reboot the standby CP before rebooting the active CP. Correct your mistake in the Security section of the configuration file and reissue the configDownload command. Do not reboot the FCS before correcting the configuration file. Note that users who attempt to upgrade switch firmware from Fabric Manager to Web Tools will see a time difference of eight hours. There are two ways to avoid this issue: ■ (Recommended) Use the command port port cfg trunk port to enable the trunk for each port. ■ Disable the long distance ports before issuing switchcfgtrunk. Wait several seconds after activating the new security policy before issuing a command to retrieve the security policy. When using the API, perform a save operation before removing multiple FCS members, if you have more than 26 switches. If you change fcpProbeDisable, make sure that you clear fcAL.fanFrameDisable to 0. SAN Director 2/128 Fabric OS 4.2.x Release Notes 23
![](/manual_guide/products/hewlettpackard-storageworks-2128-hp-storageworks-san-director-2128-fabric-os-v42x-release-notes-352aceb/23.png)