HP StorageWorks 2/140 FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Ma - Page 151
McDATA SNMP Support, NOTE
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
NOTE: This is a Fibre Channel only statistic. McDATA SNMP Support 2 FcConnUnitPortStatCountClass2PBSYFrames Type Counter64 Product Mapping Not supported. Access R Description Number of times that PBSY was returned to this port as a result of a Class 2 Frame that could not be delivered to the other end of the link. This occurs if the destination N_Port is temporarily busy. PBSY can only occur on SOFc1 frames (the frames that establish a connection). NOTE: This is a Fibre Channel only statistic. FcConnUnitPortStatCountClass2FRJTFrames Type Counter64 Product Mapping stC2FabricReject (Only supports low 32 bits of counter, high 32 bits are set to zero). Access R Description Number of times that FRJT was returned to this port as a result of a Class 2 Frame that was rejected by the fabric. NOTE: This is a Fibre Channel only statistic. FcConnUnitPortStatCountClass2PRJTFrames Type Counter64 Product Mapping Not supported. Access R Description Number of times that FRJT was returned to this port as a result of a Class 2 Frame that was rejected at the destination N_Port. NOTE: This is a Fibre Channel only statistic. Fibre Alliance MIB 2-133