HP StorageWorks 2/140 FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Ma - Page 267
connUnitSensorType, connUnitSensorCharacteristic
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 267 highlights
FC Management MIB B Access Status Description Sequence read-only mandatory This describes the status of the sensor as a message. It may also provide more resolution on the sensor indication, for example 'Cover temperature 1503K, above nominal operating range' ::= { connUnitSensorEntry 6 } connUnitSensorType Syntax Access Status Description Sequence INTEGER { unknown(1), other(2), battery(3), fan(4), power-supply(5), transmitter(6), enclosure(7), board(8), receiver(9) } read-only mandatory The type of component being monitored by this sensor. ::= { connUnitSensorEntry 7 } connUnitSensorCharacteristic Syntax INTEGER { unknown(1), other(2), temperature(3), pressure(4), emf(5), Connectivity unit group B-23
B
Connectivity unit group
B-23
FC Management MIB
Access
read-only
Status
mandatory
Description
This describes the status of the sensor as a message. It may also
provide more resolution on the sensor indication, for example 'Cover
temperature 1503K, above nominal operating range'
Sequence
::= { connUnitSensorEntry 6 }
connUnitSensorType
Syntax
INTEGER {
unknown(1),
other(2),
battery(3),
fan(4),
power-supply(5),
transmitter(6),
enclosure(7),
board(8),
receiver(9) }
Access
read-only
Status
mandatory
Description
The type of component being monitored by this sensor.
Sequence
::= { connUnitSensorEntry 7 }
connUnitSensorCharacteristic
Syntax
INTEGER {
unknown(1),
other(2),
temperature(3),
pressure(4),
emf(5),