HP StorageWorks 2/140 FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Ma - Page 156
HP StorageWorks 2/140 - Director Switch Manual
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
McDATA SNMP Support 2 Description Number of frames received with invalid CRC. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop ports should not count CRC errors passing through when monitoring. NOTE: This is a Fibre Channel only statistic. FcConnUnitPortStatCountInvalidTxWords Type Counter64 Product Mapping stInvalidTxWords (Only supports low 32 bits of counter, high 32 bits are set to zero). Access R Description Number of invalid transmission words received at this port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). NOTE: This is a Fibre Channel only statistic. FcConnUnitPortStatCountPrimitiveSequenceProtocolErrors Type Counter64 Product Mapping stPrimSeqProtoErrors (Only supports low 32 bits of counter, high 32 bits are set to zero). Access R Description Number of primitive sequence protocol errors detected at this port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). NOTE: This is a Fibre Channel only statistic. FcConnUnitPortStatCountLossofSignal Type Counter64 Product Mapping stSigLosses (Only supports low 32 bits of counter, high 32 bits are set to zero). Access R Description Number of instances of signal loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). 2-138 E/OS SNMP Support Manual