HP StorageWorks 2/8-EL SAN switch 2/8 version 3.0.x installation guide - Page 87

Environmental Requirements, Memory Specifications, Main Memory SDRAM: 32 MB per switch

Page 87 highlights

Technical Specifications Environmental Requirements Table 7 lists the environmental ranges that are acceptable when the SAN Switch EL is operating, and the acceptable ranges when the switch is not operating. Table 8: Environmental Requirements Condition Temperature (operating) Temperature (non-operating) Humidity (operating) Humidity (non-operating) Altitude (operating) Altitude (non-operating) Shock (operating) Shock (non-operating) Vibration (operating) Vibration (non-operating) Acceptable Range 10°C to 40°C -25°C to 70°C 20% to 85% RH non condensing, at 40°C 0% to 90% RH non-conducting, at 40°C 0 to 3 kilometers above sea level 0 to 12 kilometers above sea level 4G, 11MS duration, half sine 20G, 11MS duration, sq.wave 5G, 0-3 kHz at 1.0 octave/minute 10G, 0-5kHz at 1.0 octave/minute Memory Specifications The SAN Switch 2/8 uses the following memory. ■ Main Memory (SDRAM): 32 MB per switch ■ Flash Memory: Dual 8 MB ■ Boot Flash: 512K bytes of 8-bit for system boot The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and receive bandwidth to all Fibre Channel ports at all times. hp StorageWorks SAN Switch 2/8 Installation Guide 87

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Technical Specifications
87
hp StorageWorks SAN Switch 2/8 Installation Guide
Environmental Requirements
Table 7 lists the environmental ranges that are acceptable when the SAN Switch
EL is operating, and the acceptable ranges when the switch is not operating.
Memory Specifications
The SAN Switch 2/8 uses the following memory.
Main Memory (SDRAM): 32 MB per switch
Flash Memory: Dual 8 MB
Boot Flash: 512K bytes of 8-bit for system boot
The centralized memory maximizes the overall switch throughput by guaranteeing
full transmit and receive bandwidth to all Fibre Channel ports at all times.
Table 8:
Environmental Requirements
Condition
Acceptable Range
Temperature (operating)
10´C to 40´C
Temperature (non-operating)
-25´C to 70´C
Humidity (operating)
20% to 85% RH non condensing, at
40´C
Humidity (non-operating)
0% to 90% RH non-conducting, at 40´C
Altitude (operating)
0 to 3 kilometers above sea level
Altitude (non-operating)
0 to 12 kilometers above sea level
Shock (operating)
4G, 11MS duration, half sine
Shock (non-operating)
20G, 11MS duration, sq.wave
Vibration (operating)
5G, 0-3 kHz at 1.0 octave/minute
Vibration (non-operating)
10G, 0-5kHz at 1.0 octave/minute