TABLE 10, To enable signed firmware download on a disabled switch
![]() |
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
2 configure System Settings The following parameter is configurable under System settings: TABLE 10 Field Type Default Range system.blade.bladeFaultOn Number 0x0 HwErrMsk 0x0 to 0xffff system.blade.bladeFaultOnHwErrMsk If this field is set to a value other than 0, then any non fatal HW ASIC data parity error will cause the problem blade to be powered off. Examples To enable signed firmware download on a disabled switch: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] Virtual Channel parameters (yes, y, no, n): [no] F-Port login parameters (yes, y, no, n): [no] Zoning Operation parameters (yes, y, no, n): [no] RSCN Transmission Mode (yes, y, no, n): [no] Arbitrated Loop parameters (yes, y, no, n): [no] System services (yes, y, no, n): [no] Portlog events enable (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no] rpcd attributes (yes, y, no, n): [no] cfgload attributes (yes, y, no, n): [no] y Enforce secure config Upload/Download (yes, y, no, n): [no] Enforce signature validation for firmware (yes, y, no, n): [no] y webtools attributes (yes, y, no, n): [no] System (yes, y, no, n): [no :See Also configDefault, configShow, ipAddrSet, portCfgLongDistance, switchDisable, switchEnable, upTime 92 Fabric OS Command Reference 53-1000599-01
![](/manual_guide/products/hewlettpackard-ae370a-brocade-fabric-os-command-reference-guide-v600-53100059901-2008-c916318/118.png)