HP StorageWorks 4/256 Brocade Fabric OS Command Reference Guide v6.0.0 (53-100 - Page 406
perfAddEEMonitor, This command requires a Brocade Advanced Performance Monitoring license.
View all HP StorageWorks 4/256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 406 highlights
2 perfAddEEMonitor perfAddEEMonitor Adds an end-to-end monitor to a port. Synopsis perfaddeemonitor [slotnumber/]portnumber SourceID DestID Description Use this command to add an end-to-end performance monitor to a port. The performance monitor counts the number of words received, number of words transmitted, and number of CRC errors detected using either of the following two conditions: For frames received at the port, the frame SID is the same as SourceID and frame DID is the same as DestID, both RX_COUNT and CRC_COUNT will be updated accordingly. For frames transmitted from the port, the frame DID is the same as SourceID and frame SID is the same as DestID, both TX_COUNT and CRC_COUNT will be updated accordingly. To monitor traffic from host A to device B, add a monitor on port 2, specifying 0x050200 as the SID and 0x010100 as the DID. The RX count equals the number of words from host A to device B, whereas the TX count equals the number of words from device B to host A. The CRC count equals the total number of CRC errors for both directions. Adding a monitor on port 1, specifying 0x010100 as SID and 0X050200 as the DID has a similar effect, except the RX and TX counts are interchanged. If ISL monitoring is enabled, end-to-end monitors cannot be added to E_Ports. Existing end-to-end monitors on E_Ports are deleted. Identical monitors cannot be added to the same port. Two monitors are considered identical if they have the same SID and DID values after applying the end-to-end mask. After a successful execution of this command, a monitor number is displayed. The monitor number is provided for manipulation of these performance monitors. Notes This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the port on which the monitor is to be added, followed by a slash (/). portnumber Specifies the number of the port on which the monitor is to be added, relative to its slot for bladed systems. Use switchShow for a list of valid ports. SourceID Specify the 3-byte SID (Source ID) of the originator device. It should be in "0xDDAAPP" format, where DD is domain ID, AA is area ID and PP is AL_PA ID. For example, 0x050200 has a domain ID of 5, an area ID of 2, and an AL_PA ID of 0. SourceID and DestID both cannot be 0x000000. DestID Specify the 3-byte DID (destination ID) of the destination device. It should be in "0xDDAAPP" format, where DD is domain ID, AA is area ID and PP is AL_PA ID. For example, 0x050200 has a domain ID of 5, an area ID of 2, and an AL_PA ID of 0. SourceID and DestID both cannot be 0x000000. 380 Fabric OS Command Reference 53-1000599-01