HP StorageWorks 4/64 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 1
53-1001338-01 ® 28 July 2009 Fabric OS Message Reference Supporting Fabric OS v6.3.0 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 2
BigIron, DCX, Fabric OS, FastIron equipment, equipment feature, or service offered or to be support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408-333-8000 number - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 3
support March 2004 Fabric OS System Error Message 53-0000515-09 Updated for v4.4.0, Reference Manual First RASLog release August 2004 Fabric Manual 1001 Fabric OS System Error Message 53-1000046-01 Added BM, FCR, IPS, FCIP, SEC, and ZONE January 2006 Reference Manual messages Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 4
Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1000600-02 Updated for Fabric PORT, SWCH, UCST -Updated Introductory chapters. Aug 2008 53-1001157-01 Updated for Fabric , IPS, ISNS, L2SYS, MFIC, PDM, PLAT, PORT, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 5
document is organized lxiii Supported hardware and software lxiii What (syslogd 3 System Console 4 Port Logs 4 Viewing and Configuring System Message Logs 4 Viewing System Configuring Event Auditing 7 Reading a RAS System Message 8 Audit Event Messages 10 Message Severity Levels 11 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 6
Responding to a System Message 11 Looking Up a System Message 12 Gathering Information About the Problem 12 Support 13 Panic Dump and Core Dump Files 13 Trace Dumps 13 supportSave Command 13 System AG-1022 31 AG-1023 31 AG-1024 31 AG-1025 31 vi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 7
-1001 37 AN-1002 37 AN-1003 37 AUTH System Messages AUTH-1001 39 AUTH-1002 39 AUTH-1003 39 AUTH-1004 40 AUTH-1005 40 AUTH-1006 40 AUTH-1007 40 AUTH-1008 41 AUTH-1010 41 AUTH-1011 41 AUTH-1012 42 AUTH-1013 42 AUTH-1014 42 AUTH-1016 42 AUTH - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 8
ANV-1005 54 ANV-1006 54 ANV-1007 54 BKSW System Messages BKSW-1003 57 BL System Messages BL-1000 59 BL-1001 59 viii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 9
Fabric OS Message Reference 53-1001338-01 BL-1002 59 BL-1003 60 BL-1004 60 BL-1006 60 BL-1007 61 BL-1008 61 BL- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 10
79 BM-1010 79 BM-1053 80 BM-1054 80 BM-1055 80 BM-1056 80 BM-1058 81 Chapter 11 C2 System Messages C2-1001 83 C2-1002 83 C2-1004 83 C2-1006 84 C2-1007 84 C2-1008 84 C2-1009 85 C2-1010 85 x Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 11
-1005 96 Chapter 16 CNM System Messages CNM-1001 97 CNM-1002 97 CNM-1003 97 CNM-1004 97 CNM-1005 98 CNM-1006 98 Fabric OS Message Reference xi 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 12
CNM-1036 105 CNM-1037 106 CNM-1038 106 CNM-1039 106 CNM-1040 106 CNM-1041 107 CNM-1042 107 CNM-1043 107 xii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 13
115 CONF-1001 115 CONF-1020 115 CONF-1021 116 CONF-1022 116 CONF-1023 116 CONF-1024 116 CONF-1030 117 CONF-1031 117 Fabric OS Message Reference xiii 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 14
127 Chapter 20 CVLM System Messages CVLM-1001 129 CVLM-1002 129 CVLM-1003 129 CVLM-1004 129 CVLM-1005 130 CVLM-1006 130 xiv Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 15
-3023 137 CVLM-3024 138 Chapter 21 DAUTH System Messages DOT1-1001 139 DOT1-1002 139 DOT1-1003 139 DOT1-1004 139 DOT1-1005 140 Fabric OS Message Reference xv 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 16
EM-1033 150 EM-1034 150 EM-1035 151 EM-1036 152 EM-1037 152 EM-1041 153 EM-1042 153 EM-1043 153 xvi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 17
160 EM-2003 160 Chapter 23 ESS System Messages ESS-1001 161 ESS-1002 161 ESS-1003 161 ESS-1004 162 ESS-1005 162 Chapter 24 ESWCH System Messages ESW-1001 163 ESW-1002 163 ESW-1003 163 ESW-1004 164 ESW-1005 164 Fabric OS Message Reference xvii 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 18
FABR-1022 175 FABR-1023 176 FABR-1024 176 FABR-1029 176 FABR-1030 177 FABR-1031 177 FABR-1032 177 FABR-1034 178 xviii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 19
FBC-1001 189 Chapter 29 FCMC System Messages FCMC-1001 191 Chapter 30 FCIP System Messages FCIP-1000 193 FCIP-1001 193 FCIP-1002 193 Fabric OS Message Reference xix 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 20
203 FCPH-1002 203 Chapter 34 FCR System Messages FCR-1001 205 FCR-1002 205 FCR-1003 205 FCR-1004 205 FCR-1005 206 xx Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 21
Fabric OS Message Reference 53-1001338-01 FCR-1006 206 FCR-1007 206 FCR-1008 206 FCR-1009 207 FCR-1010 207 FCR-1011 207 FCR- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 22
FCR-1081 225 FCR-1082 225 FCR-1083 226 FCR-1084 226 FCR-1085 226 FCR-1086 226 FCR-1087 227 FCR-1088 227 xxii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 23
236 FICN-1027 236 FICN-1028 237 FICN-1029 237 FICN-1030 237 FICN-1031 238 FICN-1032 238 FICN-1033 238 FICN-1034 238 Fabric OS Message Reference xxiii 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 24
FICN-1064 247 FICN-1065 247 FICN-1066 248 FICN-1067 248 FICN-1068 248 FICN-1069 248 FICN-1070 249 FICN-1071 249 xxiv Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 25
-1011 258 FICU-1012 258 FICU-1013 258 FICU-1014 259 FICU-1015 259 FICU-1016 259 Chapter 37 FKLB System Messages FKLB-1001 261 Fabric OS Message Reference xxv 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 26
FSPF-1002 265 FSPF-1003 265 FSPF-1005 266 FSPF-1006 266 FSPF-1007 266 FSPF-1008 266 Chapter 40 FSS System Messages FSS-1001 269 FSS-1002 269 FSS-1003 269 FSS-1004 270 FSS-1005 270 System Messages FW-1001 275 FW-1002 275 FW-1003 275 xxvi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 27
Fabric OS Message Reference 53-1001338-01 FW-1004 276 FW-1005 276 FW-1006 276 FW-1007 277 FW-1008 277 FW-1009 277 FW- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 28
FW-1169 296 FW-1170 297 FW-1171 297 FW-1172 297 FW-1173 298 FW-1174 298 FW-1175 298 FW-1176 299 xxviii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 29
Fabric OS Message Reference 53-1001338-01 FW-1177 299 FW-1178 299 FW-1179 299 FW-1180 300 FW-1181 300 FW-1182 300 FW- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 30
FW-1311 319 FW-1312 320 FW-1313 320 FW-1314 320 FW-1315 321 FW-1316 321 FW-1317 321 FW-1318 322 xxx Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 31
Fabric OS Message Reference 53-1001338-01 FW-1319 322 FW-1320 322 FW-1321 323 FW-1322 323 FW-1323 323 FW-1324 324 FW- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 32
FW-1424 344 FW-1425 344 FW-1426 345 FW-1427 345 FW-1428 345 FW-1429 345 FW-1430 346 FW-1431 346 xxxii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 33
Fabric OS Message Reference 53-1001338-01 FW-1432 346 FW-1433 347 FW-1434 347 FW-1435 347 FW-1436 348 FW-1437 348 FW- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 34
Messages HAMK-1001 367 HAMK-1002 367 HAMK-1003 367 HAMK-1004 368 Chapter 45 HIL System Messages HIL-1101 369 HIL-1102 369 xxxiv Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 35
Fabric OS Message Reference 53-1001338-01 HIL-1103 369 HIL-1104 370 HIL-1105 370 HIL-1106 370 HIL-1107 371 HIL-1108 371 HIL- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 36
-1003 391 Chapter 50 IBD System Messages IBD-1001 393 Chapter 51 IBPD System Messages IBPD-1001 395 IBPD-1002 395 IBPD-1003 395 xxxvi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 37
Messages IPAD-1000 401 IPAD-1001 401 Chapter 54 IPS System Messages IPS-1001 403 IPS-1002 403 IPS-1003 403 IPS-1004 403 IPS-1005 404 IPS-1006 404 Chapter 55 ISCS System Messages ISCS-1000 ISNS-1011 409 ISNS-1013 409 ISNS-1014 410 Fabric OS Message Reference 53-1001338-01 xxxvii - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 38
LACP-1001 419 Chapter 62 LANCE System Messages LANCE-1000 421 Chapter 63 LFM System Messages LFM-1001 423 LFM-1002 423 LFM-1003 423 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 39
Messages MS-1001 435 MS-1002 435 MS-1003 436 MS-1004 436 MS-1005 437 MS-1006 437 MS-1008 437 MS-1009 438 Fabric OS Message Reference 53-1001338-01 xxxix - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 40
NSM-1001 449 NSM-1002 449 NSM-1003 449 NSM-1004 449 NSM-1005 450 NSM-1006 450 NSM-1007 450 NSM-1008 450 xl Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 41
System Messages PDTR-1001 461 PDTR-1002 461 Chapter 77 PLAT System Messages PLAT-1000 463 PLAT-1001 463 PLAT-1002 463 PLAT-1003 464 Fabric OS Message Reference xli 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 42
PORT-1009 470 PORT-1010 471 Chapter 80 PS System Messages PS-1000 473 PS-1001 473 PS-1002 473 PS-1003 473 PS-1004 474 PS-1005 474 PS-1006 474 Chapter 81 PSWP System Messages PSWP-1001 475 PSWP-1002 475 PSWP-1003 475 PSWP-1004 476 PSWP-1005 476 xlii Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 43
System Messages RKD-1001 487 RKD-1002 487 RKD-1003 487 RKD-1004 488 Chapter 85 RMOND System Messages RMON-1001 489 RMON-1002 489 Fabric OS Message Reference xliii 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 44
SEC-1022 502 SEC-1024 502 SEC-1025 502 SEC-1026 503 SEC-1028 503 SEC-1029 503 SEC-1030 504 SEC-1031 504 xliv Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 45
Fabric OS Message Reference 53-1001338-01 SEC-1032 504 SEC-1033 504 SEC-1034 505 SEC-1035 505 SEC-1036 505 SEC-1037 506 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 46
SEC-1110 523 SEC-1111 523 SEC-1112 523 SEC-1113 524 SEC-1114 524 SEC-1115 524 SEC-1116 524 SEC-1117 525 xlvi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 47
Fabric OS Message Reference 53-1001338-01 SEC-1118 525 SEC-1119 525 SEC-1121 526 SEC-1122 526 SEC-1123 526 SEC-1124 526 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 48
SEC-1302 544 SEC-1303 544 SEC-1304 545 SEC-1305 545 SEC-1306 545 SEC-1307 546 SEC-1308 546 SEC-1309 546 xlviii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 49
-3038 554 SEC-3039 554 SEC-3050 555 SEC-3051 555 Chapter 91 SNMP System Messages SNMP-1001 557 SNMP-1002 557 SNMP-1003 557 Fabric OS Message Reference xlix 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 50
567 SPC-3008 567 SPC-3009 567 SPC-3010 568 SPC-3011 568 SPC-3012 568 SPC-3013 568 SPC-3014 569 SPC-3015 569 l Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 51
577 SPM-3017 578 SPM-3018 578 SPM-3019 578 SPM-3020 578 SPM-3021 579 SPM-3022 579 SPM-3023 579 SPM-3024 579 Fabric OS Message Reference li 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 52
587 SSMD-1214 588 SSMD-1215 588 SSMD-1216 588 SSMD-1217 589 Chapter 96 SULB System Messages SULB-1001 591 SULB-1002 591 lii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 53
605 SWCH-1002 605 SWCH-1003 605 SWCH-1004 606 SWCH-1005 606 SWCH-1006 606 SWCH-1007 606 SWCH-1008 607 SWCH-1009 607 Fabric OS Message Reference liii 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 54
TRCE System Messages TRCE-1001 617 TRCE-1002 617 TRCE-1003 617 TRCE-1004 618 TRCE-1005 618 TRCE-1006 618 TRCE-1007 619 liv Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 55
System Messages UPTH-1001 629 UPTH-1002 629 Chapter 106 WEBD System Messages WEBD-1001 631 WEBD-1002 631 WEBD-1004 631 WEBD-1005 631 Fabric OS Message Reference lv 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 56
ZONE-1013 642 ZONE-1015 642 ZONE-1017 643 ZONE-1018 643 ZONE-1019 643 ZONE-1022 644 ZONE-1023 644 ZONE-1024 644 lvi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 57
-1055 652 Section II Audit Log Messages Chapter 112 AUDIT AG System Messages AG-1029 655 Chapter 113 AUDIT AN System Messages AN-1003 657 Fabric OS Message Reference lvii 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 58
671 Chapter 120 AUDIT HTTP System Messages HTTP-1002 673 HTTP-1003 673 Chapter 121 AUDIT IPAD System Messages IPAD-1002 675 Chapter 122 AUDIT PORT System Messages PORT-1006 677 lviii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 59
PORT-1007 677 PORT-1008 677 PORT-1009 677 Chapter 123 AUDIT SEC System Messages SEC-1113 679 SEC-1114 679 SEC-3001 679 SEC-3002 680 SEC-3003 686 SEC-3024 686 SEC-3025 687 SEC-3026 687 SEC-3027 687 SEC-3028 687 SEC-3029 688 SEC-3030 688 Fabric OS Message Reference lix 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 60
SULB-1010 704 SULB-1017 704 SULB-1018 704 SULB-1020 705 SULB-1021 705 SULB-1023 705 SULB-1024 706 SULB-1026 706 lx Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 61
717 ZONE-3008 717 ZONE-3009 717 ZONE-3010 717 ZONE-3011 718 ZONE-3012 718 ZONE-3013 718 ZONE-3014 718 ZONE-3015 719 Fabric OS Message Reference lxi 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 62
ZONE-3016 719 ZONE-3017 719 ZONE-3018 720 ZONE-3019 720 ZONE-3020 720 ZONE-3021 720 ZONE-3022 721 ZONE-3023 721 ZONE-3024 721 ZONE-3025 721 lxii Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 63
in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 64
• Brocade 5100 • Brocade 5300 • Brocade 5410 • Brocade M5424 • Brocade 5450 • Brocade 5480 • Brocade 7500 • Brocade 7500E • Brocade 7600 • Brocade 7800 • Brocade 8000 • Brocade Encryption Switch • Brocade DCX • Brocade DCX-4S • Brocade 48000 lxiv Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 65
" - "PDM System Messages" - "PLAT System Messages" - "PORT System Messages" - "RCS System Messages" - "RPCD System Messages" - "RTWR System Messages" - "SEC System Messages" - "SNMP System Messages" - "SWCH System Messages" - "TRCE System Messages" Fabric OS Message Reference lxv 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 66
Messages" - "KAC System Messages" - "KSWD System Messages" - "LANCE System Messages" - "LFM System Messages" - "MS System Messages" - "NS System Messages" - "NSM System Messages" - "PMGR System Messages" - "PORT System Messages" lxvi Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 67
Identifies the names of user-manipulated GUI elements Identifies guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 68
are used in this manual. They are listed below damage to hardware, firmware, software, or Fibre Channel, see the Brocade Glossary. For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at: http://www.snia.org/education/dictionary lxviii Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 69
the Fabric OS firmware. Other industry resources For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.org Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 70
label, as illustrated below.: *FT00X0054E9* FT00X0054E9 • The serial number label is located as follows: • Brocade 300, 4100, 4900, 5100, 5300, 7500, 7800, 8000, and Brocade Encryption Switch-On the switch ID pull-out tab located inside the chassis on the port side on the left • Brocade 5000-On the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 71
Configuring System Message Logs 4 •Reading a RAS System Message 8 •Responding to a System Message 11 •System Module Descriptions 13 Overview of System Messages This guide supports Fabric OS v6.2.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 72
Event auditing is designed to support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of fabric events. Fabric OS versions earlier than v5.2.0 generated - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 73
enable event auditing by configuring the syslog daemon to send the events to a configured remote host using the syslogIpAdd command. You can set up filters to screen out particular classes of events using the auditCfg command (the classes include zone, security, configuration, firmware, and fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 74
log and syslog (if enabled). Port Logs The Fabric OS maintains an internal log of all port activity. Each switch or logical switch maintains a log file for each port. Port logs are circular buffers that can save up to 8000 entries per logical switch. When the log is full, the newest log entries - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 75
portLogEventShow command. portLogTypeEnable Enables an event to report to the port log. Port log events are described by the portLogEventShow command. setVerbose Sets the verbose level of a particular module within the Fabric OS. supportFtp Sets, clears, or displays support FTP parameters or - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 76
service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP address as a recipient of system messages. syslogDIpRemove Removes an IP address as a recipient of system messages. syslogDIpShow Views the currently configured - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 77
[EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to Configuring Event Auditing To configure event auditing: 1. Configure the event classes you wish to audit: switch:admin> auditcfg --class 1,2,3,4,5 Audit filter is configured. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 78
1 Reading a RAS System Message 2. Verify the configuration: switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 3. Enable the audit feature: switch:admin> auditcfg --enable Audit filter is enabled. 4. Configure up to six syslog servers to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 79
has also been generated for this event. FID is the Fabric ID that can range from 0 to 128. FID 128 means the message was generated by the default switch instance. CHASSIS is the message that was generated by the chassis instance. SLOT number indicates the message was generated from slot # blade main - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 80
Note that not all message numbers are used; there can be gaps in the numeric message sequence. The severity of the error: 1 = Critical 2 = Error 3 = Warning 4 = Info The event class: Zone Security Configuration Firmware Fabric The user ID. The role of the user ID. The IP address. The interface being - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 81
logical switch name. The defined switch name or the chassis name of the switch. This fabric port. Responding to a System Message This section provides procedures on gathering information on system messages, including: • Looking Up a System Message • Gathering Information About the Problem • Support - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 82
repeatable? - If so, what are the steps to produce the problem? - What configuration was in place when the problem occurred? 8. Did a failover occur? 9. Was security enabled? 10. Was POST enabled? 11. Are serial port (console) logs available? 12. Which CP was master? (only applicable to the Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 83
Module Descriptions 1 Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section describes those files and how to access and/or save the information for support personnel. Panic Dump and Core Dump Files The Fabric OS creates panic - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 84
. Fibre Channel over IP port configuration message over Spike and Striker Blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). C2 Condor2 error messages indicate problems with the Condor2 ASIC driver module of the Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 85
lists to all switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages over Sprint and Marathon Blade. Fibre Channel miscellaneous messages relate to problems with the physical layer - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 86
information. Moreover, ICPD distributes iSCSI configurations not only switch wide, but also fabric wide. It keeps track iSCSI VT status and updates VT status to BP. System messages generated by the IP admin demon. Fibre Channel over IP license, tunneling, and port-related messages. The ISCS module - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 87
Exchange Service Support daemon (essd) • FA-API rpc daemon (rpcd) • Fabric daemon (fabricd) • Fabric switch use XISLs. This involves creating and managing LISLs in a logical fabric. RASLog subsystem. The link state database is a part of the FSPF protocol that maintains records on the status of port - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 88
from a message queue. The Management Service enables the user to obtain information about the Fibre Channel fabric topology and attributes by providing a single management access point. MS provides for both monitoring and control of the following areas: Fabric Configuration Server. Provides for the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 89
informational only and are generated even during successful firmware download. For additional information, refer to the Fabric OS Administrator's Guide. These messages are generated by the switch driver module that manages a Fibre Channel switch instance. System controller is a daemon that starts up - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 90
on configuring the track change feature, refer to the Fabric OS Command Reference or the Fabric OS Administrator's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST is a part of the fabric shortest - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 91
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 25 •AN System Messages 37 •AUTH System Messages 39 •ANV System Messages 53 •BKSW System Messages 57 •BL System Messages 59 •BLL System Messages 73 •BLS System Messages 75 •BM System Messages - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 92
387 •HTTP System Messages 391 •IBD System Messages 393 •IBPD System Messages 395 •ICPD System Messages 397 •IPAD System Messages 401 •IPS System Messages 403 •ISCS System Messages 405 •ISNS System Messages 407 •KAC System Messages 411 •KSWD System Messages 413 •KTRC System Messages - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 93
•ONM System Messages 453 •PDM System Messages 455 •PDTR System Messages 461 •PLAT System Messages 463 •PMGR System Messages 465 •PORT System Messages 469 •PS System Messages 473 •PSWP System Messages 475 •RAS System Messages 479 •RCS System Messages 483 •RMOND System Messages 489 •RKD - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 94
- HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 95
to the Fabric OS Command Reference manual for more information on this command. • Some blades and ports in a switch may not support NPIV. NPIV functionality can not be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B, for - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 96
>, Invalid response to fabric login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch. If the message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 97
,, WARNING, , Sending FLOGI failed on N_Port . Probable Cause Indicates there was a failure sending a Fabric Login (FLOGI) request from the Access Gateway to the fabric switch. Recommended Action Please check the configuration of the fabric switch connected to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 98
,, WARNING, , Sending FDISC failed on N_Port . Probable Cause Indicates there was a failure sending discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 99
Cause , [AG-1018], ,, ERROR, , Host port should not be connected to port , which is configured as N_Port. Indicates that an Initiator or Target is erroneously connected to a port configured for N_Port operation. Fabric OS Message Reference 29 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 100
], ,, WARNING, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. Probable Cause Indicates that the failover does not get blocked between two fabrics, although it is not a supported configuration. Recommended Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 101
INFO AG-1024 Message , [AG-1024], ,, INFO, , F_Port is failed back switch to display that the Trunk Area is assigned to all ports in the system and run the porttrunkarea --enable command to reconfigure the Trunk Area. Severity ERROR Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 102
CLI command on the AG switch and enable the NPIV capability on this port. Action Severity WARNING AG-1028 Message , [AG-1028], ,, WARNING, , Device with Port WWN tried to perform fabric login through port , without having access - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 103
Loop is detected for the device connected to the port. Recommended Check the device configuration. Action Severity WARNING AG-1032 Message , [AG-1032], ,, INFO, , N-Port (ID: ) has recovered from an unreliable state. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 104
>, [AG-1036], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended No action is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 105
If the switchshow command on the connected fabric switch port displays 'Persistently disabled: Area has been acquired', then check the cabling on the AG. All trunked ports in a single trunk should belong to the same ASIC Port Group. Severity INFO Fabric OS Message Reference 35 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 106
2 AG-1037 36 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 107
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR AN-1003 Message , [AN-1003], ,, WARNING, , Slot , port - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 108
3 AN-1003 38 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 109
command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set to . Probable Cause Indicates that an authentication configuration value was set to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 110
command and contact your switch service provider. Severity ERROR AUTH-1006 Message , [AUTH-1006], ,, WARNING, , Failed to open authentication configuration file. Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 111
to make sure the local switch supports the specified protocols: Fibre channel authentication protocol (FCAP) or Diffie Hellman - challenge handshake authentication protocol (DH-CHAP). Severity ERROR AUTH-1008 Message , [AUTH-1008], ,, ERROR, , No security - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 112
run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1016 Message , [AUTH-1016], , FFDC, ERROR, , Invalid value to start HBA authentication port: , . 42 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 113
and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 114
. Reinstall all PKI objects or reset the secret value for DH-CHAP properly. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. 44 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 115
. Recommended Action Check the authentication configuration and reset the supported value if needed using the authUtil command. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. Fabric OS Message Reference 45 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 116
run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1030 Message Probable Cause , [AUTH-1030], ,, ERROR, , Invalid message code for message: port . Indicates the receiving payload does not - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 117
, [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch . Indicates that an entity was not configured in the switch connection control (SCC) policy and tried to connect to the port. Fabric OS Message Reference 47 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 118
command and contact your switch service provider. Severity ERROR AUTH-1036 Message , [AUTH-1036], ,, ERROR, , Invalid state for : port . Probable Cause Indicates that the switch received an unexpected - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 119
authentication negotiation, and the local switch has a strict switch authentication policy. Recommended Correct the switch policy configuration on either of the switches using the authUtil command, and Action then enable the port using the portEnable command. Fabric OS Message Reference 49 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 120
the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch using the portEnable command. If the E_Port formed, no action is required. Severity INFO AUTH-1041 Message , [AUTH-1041], ,, ERROR - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 121
>,, ERROR, , Certificate not present in this switch in port . Probable Cause Indicates that the public key infrastructure (PKI) certificate is not installed in this switch. Recommended Action Check the certificate availability using the pkiShow - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 122
4 AUTH-1045 52 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 123
Fibre Channel cable is faulty. Replace the SFPs or the cable if necessary. Severity ERROR ANV-1002 Message , [ANV-1002], ,Ffdc, ERROR, , Port - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 124
, ,: ANVIL PASS 1 low buff pool fault: 0x. Probable Cause Indicates that Anvil Pass 1 is out of free buffer which might cause a chip fault. Recommended Reconfigure the testing setup. Action 54 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 125
Severity CRITICAL DRAFT: BROCADE CONFIDENTIAL ANV-1007 5 Fabric OS Message Reference 55 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 126
5 ANV-1007 DRAFT: BROCADE CONFIDENTIAL 56 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 127
found, run supportFtp to send all the core files to a secure server location. Copy the error message and any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 57 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 128
6 BKSW-1003 58 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 129
not have hardware problems. To run this command root access is required. To run this command root access is required. Refer to the Fabric OS Command Reference Manual for more information on this command. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 130
problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric slot . Probable Cause Indicates that the specified blade experienced a failure but was not faulted due to a user setting. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 131
Message , [BL-1008], , FFDC, CRITICAL, , Slot control-plane failure. Expected value: 0x< problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 132
the blade or the (nonbladed) switch. Severity CRITICAL BL-1012 Message , [BL-1012], ,, ERROR, , bport port int. is disabled. status=0x Port will be re-enabled in 1 minute. 62 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 133
, bport port is faulted. status=0x Port will be re-enabled in 1 minute. Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch operation. The port is disabled to prevent the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 134
>, Blade port in slot failed to enable. Probable Cause Indicates that the specified blade port has failed to get enabled. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade. 64 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 135
problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric -number>,, INFO, , Slot , retry , internal port retry initialization, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 136
) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the switch. Severity CRITICAL BL-1021 Message , [BL-1021], ,, INFO, , Retry , internal port retry initialization - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 137
Virtualization ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 138
BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 139
Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel over IP (FCIP - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 140
that the slot has completed initializing Fibre Channel (FC) ports. Recommended No action is required. Action Severity INFO BL-1035 Message , [BL-1035], ,, INFO, , Slot iSCSI port Initialization completed. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 141
chip and that all ports on the chip have been disabled. Recommended No action is required. Action Severity CRITICAL BL-1038 Message , [BL-1038], ,, CRITICAL, , Inconsistent FPGA image version detected, please restart the switch for recovery. Probable - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 142
7 BL-1039 72 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 143
slot number> port as faulty (reason: ) Probable Cause Indicates a blade regulation problem was reported on the specified slot number. blade does not have any hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 144
8 BLL-1000 Severity CRITICAL 74 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 145
,, ERROR, , of GE failed configuration file was updated. Recommended No action is required. Action Severity INFO BLS-1003 Message , [BLS-1003], ,, INFO, , An IPsec/IKE policy was deleted. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 146
system-name>, Tape Read Pipelining is being disabled slot port tunnel . Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support the Tape Read Pipelining feature. Recommended No action is required - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 147
download is supported between the revisions. Because the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If needed, send the AP blade back to the factory for a firmware update. Severity ERROR BM-1002 Message , [BM-1002], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 148
will automatically download the updated firmware. Action Severity INFO BM-1005 Message , [BM-1005], ,, WARNING, was configured under a different mode. Recommended Configure the blade so that it will persistently enable the ports. Action Severity INFO 78 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 149
. On the Brocade Action 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message , [BM-1010], ,, INFO, , Resetting port configuration and linkcost for all ports for blade in slot - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 150
7600, turn off and turn on all primary power in order to power-cycle the unit. Severity WARNING BM-1056 Message , [BM-1056], ,, INFO, , AP is not configured. Persistently disabling all ports on the switch. 80 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 151
on this switch. • The switch was configured under a different mode. Recommended Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 152
10 BM-1058 82 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 153
Fibre Channel cable is not faulty. Replace SFPs or cable if necessary. Severity ERROR C2-1002 Message , [C2-1002], ,, ERROR, , Port chip faulted due to an internal error. Probable Cause Internal error. All the ports on the blade or switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 154
action required by the user at this time. If number>,, WARNING, , , : At next port state change, best effort QOS will be turned off automatically as it is no longer supported under this configuration Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 155
sequence-number>,, WARNING, , , : reset, or it may indicate that the identified hardware needs to be replaced. Recommended Power cycle the faulted blade. If the problem persists, replace the blade. Action Severity CRITICAL Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 156
11 C2-1010 86 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 157
pair, a faulty cable between peer ports, or that the port speed configuration does not match the capability of the SFP. Recommended Action Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have deteriorated or the Fibre Channel cable is faulty. Replace the SFPs - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 158
, [CDR-1005], ,, WARNING, , , : at next port state change, best effort QOS will be turned off automatically due to best effort is no longer supported under this configuration. Probable Cause Indicates QoS will be - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 159
of a module within the Converged Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CCFG - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 160
Cause Indicates that the startup configuration has been moved or deleted. Recommended No action is required. Action Severity INFO CCFG-1008 Message , [CCFG-1008], ,, ERROR, , CMSH init failed: . 90 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 161
no linecard command to remove configuration. Action Severity WARNING CCFG-1012 Message , [CCFG-1012], ,, ERROR, , Blade in slot failed to reach ONLINE state within seconds after receiving system ready. Fabric OS Message Reference 91 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 162
ready event. Recommended Run the slotpoweroff command followed by the slotpoweron command on the slot to retry bringing Action the slot online. Severity ERROR 92 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 163
CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active CP. Severity ERROR Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 164
14 CER-1001 94 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 165
, run the fastBoot command on the switch to recover the system. Severity ERROR CHASSIS-1003 Message , [CHASSIS-1003], ,, ERROR, , Slot ENABLED but Not Ready during recovery, disabling slot = rval = . Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 166
Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR 96 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 167
firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CNM-1003 Message , [CNM-1003], ,, WARNING, , Crypto device configuration between local switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 168
16 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [ - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 169
the node to the encryption group (EG). Action Severity INFO CNM-1012 Message Probable Cause , [CNM-1012], ,, INFO, ,Posting event CNM_EVT_EG_DELETED. Indicates that the encryption group (EG) is deleted. Fabric OS Message Reference 99 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 170
No action is required. Action Severity INFO CNM-1016 Message Probable Cause , [CNM-1016], ,, INFO, ,Posting event Detected a EG degrade condition. Indicates an encryption group (EG) degrade condition. 100 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 171
>, [CNM-1017], ,, INFO, ,Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. ,, INFO, , Node Admission Control failed, due to mismatch in certificates, rejecting node []. Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 172
. Action Severity INFO CNM-1023 Message , [CNM-1023], ,, INFO, , Group Leader node eject is not allowed. Probable >, [CNM-1024], ,, INFO, , Operation not required on GL node. 102 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 173
Cause Indicates that a version mismatch has occurred. Recommended Upgrade the firmware or delete the Node from the encryption group (EG). Action >, [CNM-1028], ,, INFO, , Certfile already exists. No need to sync up. Fabric OS Message Reference 103 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 174
Action Severity INFO CNM-1029 Message , [CNM-1029], ,, WARNING, , Certfile content does not match the ,, WARNING, , Certfile size does not match cert file size sent by GL 104 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 175
in a degraded state. Recommended No action is required. Action Severity WARNING CNM-1036 Message , [CNM-1036], ,, INFO, , All the active nodes of the cluster are in ONLINE state. Posting converged event. Fabric OS Message Reference 105 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 176
INFO CNM-1038 Message , [CNM-1038], ,, INFO, , Split-Brain Arbitration won, majority GL number>,, INFO, , Split-Brain Arbitration won, Majority WWN/GL Node, remote_wwn:local_wwn . Indicates that split arbitration is won. 106 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 177
,, ERROR, , Received HBT from undefined node IpAddress [], WWN []. Possible configuration error. number>,, ERROR, , Cluster Create Failed as the Certificate files not found, Please do the initnode. Indicates that the initnode is not invoked. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 178
Message , [CNM-1047], ,, INFO, , Network Interface to Remote Node is . Probable Cause Indicates that CNM-1048], ,, INFO, , Posting . Indicates the event that is posted. 108 Fabric OS Message Reference 53- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 179
mode mismatch between the switches like the Access Gateway mode number>,, ERROR, , Member node registered with another Encryption Group. To proceed eject the member node from other EG.. Indicates that the member node is registered with another encryption group (EG). Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 180
Probable Cause , [CNM-1056], ,, INFO, , Posting event CNM_EVT_EE_INITIALIZING Slot , Wwn , IP , flags . Indicates that the encryption engine (EE) is added into the encryption group (EG). 110 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 181
>, [CNM-1058], ,, INFO, , Posting event CNM_EVT_OFFLINE Slot , Wwn , IP , flags . Probable Cause -number>,, INFO, , Event: cryptocfg Status: success, Info: encryption group deleted. Indicates an encryption group was deleted. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 182
Action Severity INFO CNM-3006 Message Probable Cause , [CNM-3006], ,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat miss count set to . Indicates that the heartbeat miss value was set. 112 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 183
. Action Severity INFO CNM-3010 Message Probable Cause , [CNM-3010],,, INFO, , Event: cryptocfg Status: success, Info: Membernode deregistered. Indicates a member node was deregistered. Fabric OS Message Reference 113 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 184
, [CNM-3011], ,, INFO, , Event: cryptocfg Status: success, Info: Encryption group synchronized. Probable Cause Indicates an encryption group was synchronized. Recommended No action is required. Action Severity INFO 114 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 185
successfully. The statement that follows, message strings, is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity INFO CONF-1001 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 186
CONF-1022 Message , [CONF-1022], ,, WARNING, , Downloading configuration without disabling the switch was unsuccessful. Probable Cause Indicates an attempt to download the configuration without disabling the switch was unsuccessful because there are one or - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 187
[CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable Cause Indicates that the previous configuration commands have resulted in a database full condition. Configuration changes associated with the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 188
17 CONF-1041 CONF-1041 Message , [CONF-1041], ,, INFO, , configRemove failed. Probable Cause Indicates a configRemove error has occurred. Recommended Correct the error and try again. Action Severity INFO 118 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 189
Chapter CTAP System Messages 18 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 190
18 CTAP-1001 120 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 191
LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, completed or cancelled. Recommended . Recommended No action is required. Action Severity INFO Fabric OS Message Reference 121 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 192
>, [CVLC-1005], ,, INFO, , There enabled.\nContainer: , Initiator: , LUN ID: . Indicates that there has been an attempt to remove the encryption LUN while decryption of existing data is still enabled. 122 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 193
-number>,, ERROR, , Tape license is required for tape container: . Probable Cause Indicates that the tape container is configured with non-Brocade mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 194
sequence-number>,, key record base on the user input.\nContainer: , Initiator: , LUN ID: . Indicates that the data state in the LUN configuration is in the encrypted state without a key ID and there is no metadata found on the LUN. 124 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 195
Indicates that the LUN is set as read-only because there is a conflict in the configuration. Recommended No action is required. Action Severity INFO CVLC-1016 Message , [CVLC-1016], ,, INFO, , LUN is out of read only mode. Reason: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 196
exists on the LUN that is clear text. Recommended Use cryptocfg command to confirm the configuration. Action Severity ERROR CVLC-1021 Message , [CVLC-1021], ,, INFO, , User provided key ID is ignored while metadata - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 197
19 CVLC-1022 CVLC-1022 Message , [CVLC-1022], ,, INFO, , User provided key ID is ignored while data state is clear clear text. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 127 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 198
19 CVLC-1022 128 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 199
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CVLM-1003 Message , [CVLM-1003], ,, INFO, , Crypto device configuration - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 200
Action the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch. Probable Cause Indicates that Crypto service is enabled or disabled - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 201
member of HAC is found in the fabric. Recommended No action is required. Action Severity INFO CVLM-1010 Message , [CVLM-1010], ,, WARNING, , The IP address of EE IO link is not configured. Probable Cause Indicates that the EE - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 202
-3004 Message Probable Cause , [CVLM-3004], ,, INFO, , Event: cryptocfg Status: success, Info: Cluster member added to HA cluster . Indicates an HA cluster member was added to an HA cluster. 132 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 203
. Action Severity INFO CVLM-3008 Message Probable Cause , [CVLM-3008],,, INFO, , Event: cryptocfg Status: success, Info: Container \\ deleted. Indicates a cryptotarget container was deleted. Fabric OS Message Reference 133 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 204
is required. Action Severity INFO CVLM-3012 Message , [CVLM-3012],,, INFO, , Event: cryptocfg Status: success, Info: Initiator \\ removed from crypto target container \\. 134 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 205
required. Action Severity INFO CVLM-3014 Message , [CVLM-3014], ,, INFO, , Event: cryptocfg Status: success, Info: Lun < a cryptotarget container. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 135 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 206
Probable Cause Indicates a LUN in a cryptotarget container was enabled. Recommended No action is required. Action Severity INFO CVLM-3017 Message , [CVLM-3017], ,, INFO, , Event: cryptocfg Status: success, Info: Tape pool \\ created - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 207
, [CVLM-3023], ,, INFO, , Event: cryptocfg Status: success, Info: Transaction committed. Probable Cause Indicates a transaction commit operation was performed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 137 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 208
>, [CVLM-3024], ,, INFO, , Event: cryptocfg Status: success, Info: Transaction aborted. Probable Cause Indicates a transaction abort operation was performed. Recommended No action is required. Action Severity INFO 138 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 209
.1X is enabled for a particular port. Recommended No action is required. Action Severity INFO DOT1-1004 Message Probable Cause , [DOT1-1004], ,, INFO, Port is forcefully unauthorized. Indicates that the port is unauthorized forcefully. Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 210
whether the configured RADIUS servers are reachable and are functioning. Action Severity CRITICAL DOT1-1008 Message Probable Cause , [DOT1-1008], ,, INFO, Port is forcefully authorized. Indicates that the port is authorized forcefully. 140 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 211
Action Severity INFO DOT1-1010 Message , [DOT1-1010], ,, INFO, Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 141 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 212
21 DOT1-1010 142 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 213
temperature is within the operational range of the switch. Refer to the Hardware Reference Manual for the environmental temperature range of your switch. Run the fanShow command to verify that all the specified FRU. Restart or power cycle the switch. Fabric OS Message Reference 143 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 214
switch does not have hardware problems. To run this command root access is required. Refer to the Fabric type string and an optional number to identify the unit, slot, or port. The Brocade 3250 has and 1 power supply, but these parts cannot be replaced: the entire switch is a FRU. Recommended Try - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 215
the blade. If this problem occurs on a switch, it usually indicates a hardware problem on the main board; replace the switch. Severity CRITICAL EM-1007 Message , [EM-1007], , FFDC, CRITICAL, , is being reset. Sensors has exceeded max limits - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 216
Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 Message , [EM-1010], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 217
displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action On Brocade DCX, 24000 and FRU. Severity ERROR EM-1014 Message , [EM-1014], ,, ERROR, , Unable to read sensor on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 218
EM-1019 Message , [EM-1019], ,, WARNING, , Current chassis configuration option () is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync. 148 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 219
option is not supported by the firmware on the standby switch (for nonbladed switches). Severity WARNING EM-1029 Message , [EM-1029], ,, WARNING, , , a problem number>,, ERROR, , ejector not closed. Fabric OS Message Reference 149 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 220
port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch CP reboots, even as part of a clean warm switch does not have hardware problems. To run this command root access is required. Refer to the Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 221
22 EM-1035 EM-1035 Message , [EM-1035], ,, ERROR, , 2 circuit paired Power Supplies are faulty, please check the AC main switch/circuit to see if it has power. Fabric OS Message Reference 151 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 222
that the switch does not have hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace the FRU. Severity WARNING EM-1037 Message , [EM-1037], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 223
Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU header-derived information. This could mean that -1044], ,, WARNING, , Can't power on , its logical switch is shut down Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 224
the lscfg command to correct the switch or port configuration for the ports on that blade. Severity WARNING EM-1047 Message , [EM-1047], ,, INFO, , CP in slot not faulty, CP ERROR deasserted. 154 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 225
timestamp>, [EM-1048], ,, INFO, , I2C access recovered: state Probable Cause Indicates that the I2C bus problems have been resolved and I2C access FRU as soon as possible. Action Severity INFO Fabric OS Message Reference 155 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 226
>, with id cannot be found in the fru description xml file. Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is not compatible with the switch configuration software. The system may not be usable. 156 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 227
is compatible with your switch type. Action Severity ERROR EM-1060 Message , [EM-1060], ,, WARNING, , [EM-1062], ,, CRITICAL, , Blade in slot faulted as it exceeds the maximum support limit of blades - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 228
have selected to power off the problem blade when such a condition occurred. Recommended Contact the switch provider for support. Action Severity CRITICAL EM-1065 Message , [EM-1065], ,, WARNING, , SSAS Virtualization Services are not available due to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 229
data. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Reboot or power cycle the switch. If the message persists, collect switch information using the Action supportsave command, and contact your switch service provider. Severity ERROR EM-1069 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 230
does not have hardware problems. To run this command root access is required. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR 160 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 231
>, [ESS-1001], ,, WARNING, , A few switches in the fabric do not support the Coordinated HotCode protocol. Probable Cause Indicates one or more switches in the fabric do not support the Coordinated HotCode protocol. Continuing with the firmware download may cause data - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 232
domain id>. Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 233
ENABLED but Not Ready during recovery, disabling slot = (). Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery. Recommended On a Brocade 8000 switch, restart or power cycle the switch. Action Severity ERROR Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 234
logged into the fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDOwnload Action command. Severity WARNING ESW-1007 Message , [ESW-1007], ,, WARNING, ,Switch port disabled due to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 235
that do not support port swap. Slot will be faulted. Probable Cause Indicates that the blade has area swapped ports on ports that do not support this feature. Recommended Replace the blade with ports that support port swap. Refer to the Fabric OS Administrator's Guide Action for more - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 236
24 ESW-1008 DRAFT: BROCADE CONFIDENTIAL 166 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 237
-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause switch cannot be reached through in-band. Recommended Please make sure that the specified remote domain is present in the fabric. Action Severity WARNING Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 238
25 EVMD-1001 168 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 239
[FABR-1001], ,, WARNING, , port , . Probable Cause Indicates that the specified switch port is isolated because of a segmentation resulting from mismatched configuration parameters. Recommended Action Based on the segmentation reason - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 240
your switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: , sent. The fabric received an unknown response. This message is rare and usually indicates a problem with the Fabric OS kernel. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 241
command and contact your switch service provider. Severity WARNING FABR-1009 Message Probable Cause , [FABR-1009], ,, WARNING, , . Indicates that errors were reported during the exchange fabric parameter state; cannot allocate - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 242
a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message , [FABR-1011], , FFDC - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 243
a different domain ID, then the port is disabled. Recommended Action Run the configShow command to view the fabric.ididmode. A '0' means the IDID mode is disabled; a '1' means it is enabled. Set the switch to insistent domain ID mode. This mode is set under the configure command or in Web Tools on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 244
-number>,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface number>, FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration (). 174 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 245
limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer ( - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 246
the licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration (). Fabric limit timer () stopped at - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 247
This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control. • DUAL_CR mode: Dual-credit flow control mode. In both of the previous modes, the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are negotiated as part of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 248
not have Trunk Area enabled. Action Severity INFO FABR-1037 Message , [FABR-1037], , INFO, , Port configuration incompatible with Trunk Area enabled port. Persistently disabling port . 178 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 249
is enabled without a trunking license being present. Recommended Install a trunking license or disable F_port trunking on the port. Action Severity INFO FABR-1039 Message , [FABR-1039], , WARNING, , Invalid domain id zero received from principal switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 250
the switch Action firmware to a VF-capable firmware. Severity ERROR FABR-1044 Message , [FABR-1044], , ERROR, , Detected Fabric ID conflict with neighbor switch (domain ), FID . E-ports ( - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 251
. All the E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF-capable firmware. Severity ERROR Fabric OS Message Reference 181 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 252
26 FABR-1046 182 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 253
is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 254
an invalid value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. 184 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 255
Probable Cause Indicates that the Fabric OS detected an unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 256
is usually an internal Fabric OS problem. Recommended Action Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR FABS-1013 Message , [FABS-1013], ,, ERROR, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 257
, , []:Request to enable FRU type 0x, unit failed. err code Probable Cause Indicates the specified FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 258
27 FABS-1015 188 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 259
disruptive firmwareDownload is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If required, send the AP blade back to the factory to get a new firmware version installed. Severity ERROR Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 260
28 FBC-1001 190 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 261
allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message Reference 191 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 262
29 FCMC-1001 192 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 263
], , FFDC, ERROR, , of GE failed. Please Number>. Probable Cause Indicates that an FIPS failure has occured and requires faulting the blade or switch number>, INFO, CFG, , An IPsec/IKE policy was deleted. Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 264
slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support Tape Read Pipelining. Recommended No action is required. Action Severity INFO 194 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 265
. Recommended Check the switch memory status. Action Severity ERROR FCOE-1002 Message , [FCOE-1002], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 266
reached the maximum. Recommended Check the IfIndex Limit. Action Severity ERROR FCOE-1008 Message Probable Cause , [FCOE-1008], ,, INFO, , Free RASLOG fill this later. Indicates an informational message. 196 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 267
to add errda to VLAN. Action Severity ERROR FCOE-1012 Message Probable Cause , [FCOE-1012], ,, ERROR, , Request to delete port from VLAN failed. Indicates a delete port request to a VLAN has failed. Fabric OS Message Reference 197 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 268
add MACs to L2 for slot/port. Action Severity ERROR FCOE-1016 Message Probable Cause , [FCOE-1016], ,, ERROR, , Request to delete VLAN failed. Indicates a delete request to delete a VLAN has failed. 198 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 269
[FCOE-1018], ,, ERROR, , Request to delete MACs from L2 for slot/port failed. Probable Cause Indicates a delete request for slot or port has failed. Recommended Rerequest to add MACs from L2 for slot/port. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 270
31 FCOE-1018 DRAFT: BROCADE CONFIDENTIAL 200 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 271
Messages 32 FCPD-1001 Message , [FCPD-1001], ,, WARNING, , Probing failed on . Probable Cause Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing failed on the L_Port, AL_PA address, or the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 272
32 FCPD-1003 202 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 273
Message , [FCPH-1001], , FFDC, CRITICAL, , : failed, out of memory condition Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 274
33 FCPH-1002 204 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 275
>,, INFO, , FC router proxy device in edge created at port . Probable Cause Indicates that a proxy device at the port in the edge fabric has been imported at the specified port. Recommended No action is required. Action Severity INFO FCR-1002 Message , [FCR - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 276
INFO, , FC router LSAN zone deleted at port . Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port was deleted from the edge fabric. Recommended No action is required. Action Severity INFO FCR-1008 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 277
, FC router LSAN zone enabled at port : . Probable Cause Indicates that a logical storage area network (LSAN) zone was enabled in the edge fabric attached to the specified port. The enabled LSAN zone configuration is listed. Recommended No action is required - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 278
-1012 Message , [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended No action is required. Action Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 279
port resources. Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with the port resource problem. zone database limitations. Recommended Action Remove excess LSAN zones so that the number of LSAN zones created is within the range of local database limitations. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 280
exhausted. Probable Cause Indicates that the number of port world wide names (WWNs) in use exceeds the local port WWN resources. Recommended Action Limit the number of port WWNs required by limiting the remote edge fabric connectivity (which limits the number of translate domains). You can also - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 281
EX_Ports attached to fabrics with highly dynamic changes to EX_Port connectivity should be disabled and then re-enabled. Severity INFO FCR-1027 Message , [FCR-1027], ,, INFO, , In slot port WWN roll over. Fabric OS Message Reference 211 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 282
WWN conflicts, all EX_Ports attached to fabrics with highly dynamic changes to EX_Port connectivity should be disabled and then re-enabled. Severity INFO FCR-1029 Message , [FCR-1029], ,, INFO, , In slot port WWN pool 95 percent allocated - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 283
INFO FCR-1032 Message , [FCR-1032], ,, INFO, , Edge fabric enabled security on port in fabric . Probable Cause Indicates that Secure mode was turned on in the edge fabric. Recommended No action is required. Action Severity INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 284
specified logical storage area network (LSAN) zone was enabled in the backbone fabric. The enabled LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO FCR-1037 Message , [FCR-1037], ,, INFO, , LSAN zone disabled in - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 285
by entries, in zone: , zone limit: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch&apos zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 286
the supportShow command, and contact your switch service provider. Severity ERROR FCR-1049 Message Probable Cause , [FCR-1049], ,, ERROR, , EX port () received an ELP command that is not supported. Indicates an incoming exchange link protocol - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 287
the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port was disabled, . Probable - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 288
the switch with Action one that supports backbone to edge routing. Severity INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX_Port() incompatible long distance parameters on link. Probable Cause Indicates that the port, which is configured - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 289
FCR-1060], ,, WARNING, , EX_Port() has an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch and the remote switch is negotiating in R_RDY mode. The fabric might not form properly - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 290
VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port. Recommended No action is required. Action Severity INFO FCR-1063 Message , [FCR-1063], ,, INFO, , Fabric for switch with domain ID - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 291
zones and aliases, exceeded on port by entries; max entries: . Probable Cause Indicates that the total number of zone configurations created in the connected fabric exceeds the maximum number supported by the Fibre Channel. The limit includes both active - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 292
set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 293
the switch in the backbone or edge that supports a different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Ensure that total number of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 294
re-enable the port. Recommended Make sure to remain within the maximum of supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], ,, WARNING, , Port rejected fabric binding request/check from the M-Model switch; - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 295
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected pause message. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 296
-number>,, ERROR, , HA sync lost as remote CP does not support Condor2 based EX_ports. Indicates that the remote control processor (CP) has older firmware, which does not support Condor-based EX_ port. This is causing the loss of the high-availability (HA) synchronization. 226 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 297
the EX_Port connects to logical fabric containing a domain has the capability to use XISL. Recommended Disable the 'Allow to use XISL' mode of the domain by using the configure command. Action Severity ERROR FCR-1088 Message , [FCR-1088], ,, INFO, , LSAN - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 298
, [FCR-1089], ,, ERROR, , FCR ELS trap entries exhausted. Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Collect supportsave data and send it to support. Action Severity ERROR 228 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 299
where: VE - VE Port Number: This number represents the FCIP Tunnel number through its VE Port number. HD - Host switch Domain number: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 300
Enabled or Disabled>. Probable Cause Indicates the configuration was changed manually. Recommended No action is required. Action Severity INFO FICN-1006 Message , [FICN-1006], ,, WARNING, , FICON GEPort < 0 or 1 - GE port number> TID - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 301
was received from the channel as a part of path recovery. Recommended If there was a job failure associated with this event, please contact your vendor's customer support Action for assistance. Severity ERROR FICN-1009 Message , [FICN-1009], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 302
Channel. Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity INFO FICN-1011 Message , [FICN-1011], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 303
customer support Action for assistance. Severity INFO FICN-1015 Message , [FICN-1015], ,, number>,, INFO, , DevIng:Received Logical Path Established response:Path=0x8X4X2X. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 304
Probable Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity ERROR 234 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 305
. Probable Cause Indicates the FICON channel issued a Selective Reset sequence for a device. Recommended If there was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity ERROR Fabric OS Message Reference 235 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 306
support for assistance. Severity ERROR FICN-1026 Message , [FICN-1026], ,, INFO, , DevTapeIng:UnusualStatus:WriteCancelSelr:Generating Final Ending a Device Level Exception frame to the emulation processing. 236 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 307
a Selective Reset from the FICON channel. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1030 Message , [FICN-1030], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 308
FICN-1031 Message , [FICN-1031], ,, WARNING, , HostDiskIng:FICON System Reset received on Path=. Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 309
that the channel side noted corruption from the device/CU side processing. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, , HostIng:FICON System Reset received on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 310
Cause Indicates a locally connected FICON channel sent a frame that could not be associated with a FICON device. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1039 Message , [FICN-1039], ,, ERROR, , HostIng - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 311
. Probable Cause Indicates that protocol errors in emulation in the CU or network errors can cause Selective Reset. Recommended If this was an unexpected event, please contact your vendor's customer support for assistance. Action Severity ERROR Fabric OS Message Reference 241 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 312
device> treating as system reset event. Probable Cause Indicates an LRJ from a FICON channel indicates that the channel believes that it no longer has a path established to the CU. Recommended This is normally an unexpected event, please contact your vendor's customer support for Action assistance - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 313
a far side FICON end point indicates that it no longer has an established path to its peer. Recommended This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1051 Message , [FICN-1051], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 314
WARNING FICN-1055 Message , [FICN-1055], ,, WARNING, , XRC All Devices Suspended: SessID=, Path= . 244 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 315
contact your vendor's customer support for assistance. Action Severity ERROR FICN-1058 Message , [FICN-1058], ,, ERROR, , event, contact your vendor's customer support for assistance. Action Severity ERROR Fabric OS Message Reference 245 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 316
fast path hash table entry. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message , [FICN-1062], ,, ERROR, , Ingress Abort:Oxid=0x:Path - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 317
Domain>. Probable Cause Indicates an abort operation has been received from a peer FC interface for an exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity INFO Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 318
Cause , [FICN-1069], ,, ERROR, , Emulation Configuration Error on TunnelId . Indicates an error has been noted in the FICON configuration. Refer to the string for the nature of the configuration issue. 248 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 319
configuration issue cannot be completed, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1070 Message , [FICN-1070], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 320
the number of emulated read megabytes processed while this tape was loaded>. Probable Cause Indicates a Rewind and Unload IO has been processed from a locally connected LPAR and Read Block pipelining was performed on the currently loaded tape. Recommended No action is required. Action 250 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 321
this tape was loaded>:MBytes= Indicates a Rewind and Unload IO has been processed from a remotely connected LPAR and write pipelining was performed on the currently loaded tape. Fabric OS Message Reference 251 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 322
FICN-1080], ,, INFO, lastStatus=0x treating as system reset event. Indicates an LRJ from a FICON channel indicates that the channel does not have a path established to the CU. 252 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 323
, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1085 Message , [FICN-1085], ,, INFO, , FICON FCIP Tunnel is Up on GE,tunnel Id=. Fabric OS Message Reference 253 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 324
GE1>,tunnel Id=. Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR 254 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 325
management functions failed. The key variable is a part of the Fabric OS configuration database and is for support use only. The error variable is an internal error number. Recommended Action Execute an haFailover command on the switch if it has redundant control processors (CPs) or restart - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 326
that the initialization of a module within the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 327
the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message , [FICU-1008], ,, WARNING, , FMS mode has been enabled. Ports: have been disabled due to port address conflict. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 328
timestamp>, [FICU-1010], ,, WARNING, , FMS Mode enable failed due to address conflict with port . Probable Cause Indicates that the Fibre Connectivity (FICON) Management Server mode (fmsMode) was not enabled because the specified port which has an address - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 329
timestamp>, [FICU-1016], ,, INFO, , CUP Exchange Abort - PortIdx(%02X), PortAddr(%02X), XID(%02X). Probable Cause Indicates that the CUP Exchange Abort was received. Recommended No Action is required. Action Severity INFO Fabric OS Message Reference 259 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 330
36 FICU-1016 260 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 331
FKLB System Messages 37 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause the exchange out. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 261 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 332
37 FKLB-1001 262 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 333
, [FLOD-1001], , FFDC, WARNING, , Unknown LSR type: port , type Probable system can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 334
>,, WARNING, , Transmitting invalid domain ID: Probable Cause Indicates that the transmit LSR contained an invalid domain number. Recommended No action is required because the LSR is discarded. Action Severity WARNING 264 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 335
-name>, Remote Domain ID out of range, input port = Probable Cause Indicates that the specified remote domain ID is out of range. Recommended No action is required because the frame is discarded. Action Severity ERROR Fabric OS Message Reference 265 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 336
than 0 is incompatible in a fabric of SilkWorm switches. Disconnect the offending switch. Severity ERROR FSPF-1006 Message , [FSPF-1006], ,, ERROR, , FSPF Version not supported, input port = Probable Cause Indicates that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 337
Recommended No action is required. Action Severity INFO 39 FSPF-1008 Fabric OS Message Reference 267 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 338
39 FSPF-1008 268 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 339
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], , SLOT cp-slot-number | CHASSIS, WARNING, , Component () sending too many concurrent HA - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 340
the supportSave command and contact your switch service provider. Severity WARNING FSS-1007 Message , [FSS-1007], , SLOT cp-slot-number | CHASSIS, CRITICAL, , : Faulty Ethernet connection. 270 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 341
to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message , [FSS-1008], , SLOT cp-slot-number | CHASSIS, CRITICAL - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 342
40 FSS-1011 FSS-1011 Message , [FSS-1011], , SLOT cp-slot-number | CHASSIS, INFO, , FSS Info: . Probable Cause Indicates an informational message only. Recommended No action is required. Action Severity INFO 272 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 343
was logged as a result of a user-initiated action (such as running the Reboot switch service provider. Severity WARNING FSSM-1004 Message , [FSSM-1004], , SLOT cp-slot-number | CHASSIS, INFO, , Incompatible software version in HA synchronization. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 344
causes a disruptive firmware upgrade or downgrade. Recommended For a dual CP system, run the firmwareDownload command to load compatible firmware on the Action standby CP. For details on this command, refer to the Fabric OS Command Reference Manual. Severity INFO 274 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 345
your lab. Severity INFO FW-1002 Message , [FW-1002], ,, WARNING, , , is below low boundary (High= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 346
that the speed of the fan has changed. Fan problems typically contribute to temperature problems. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Consistently abnormal fan speeds generally indicate that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 347
view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 Message Probable Cause , [FW-1010], ,, WARNING, , , is below low boundary(High=, Low= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 348
policy of the Action end-user installation. Severity INFO FW-1034 Message , [FW-1034], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . 278 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 349
appropriate to the particular policy of the Action end-user installation. Severity WARNING FW-1035 Message , [FW-1035], ,, WARNING, , , is If this message occurs repeatedly, Action replace the SFP. Fabric OS Message Reference 279 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 350
it deteriorates. Action Severity WARNING FW-1040 Message , [FW-1040], ,, INFO, , , is between high and low boundaries(High= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 351
damage from heat or age. Severity WARNING FW-1043 Message , [FW-1043], ,, WARNING, , , is above high boundary(High=, Low= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 352
particular policy of the Action end-user installation. Severity INFO FW-1045 Message , [FW-1045], ,, INFO, ,, WARNING, , , is above high boundary(High=, Low=). Current value is . 282 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 353
, [FW-1048], ,, INFO, , , end-user installation. Severity INFO FW-1049 Message , [FW-1049], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 354
particular policy of the Action end-user installation. Severity INFO FW-1113 Message , [FW-1113], ,, INFO, , number>,, INFO, , , is below low boundary(High=, Low=). Current value is . 284 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 355
Action end-user installation. Severity INFO FW-1117 Message Probable Cause , [FW-1117], ,, INFO, , , value has changed(High=, Low=). Current value is . Indicates that the number of fabric reconfigurations has - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 356
link has segmented from the fabric. A low number of fabric reconfigurations means that the fabric is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1119 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 357
domain ID to the switch. A low number of domain ID changes means that the fabric is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 287 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 358
single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1124 Message , [FW-1124], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 359
parameters result in segmentation. A low number of segmentation errors means that the fabric is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1127 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 360
a change to the effective zone configuration. A low number of zone configuration changes means that the fabric is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1131 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 361
that the number of fabric logins has changed. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 362
above the high boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 363
to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1160 Message Probable Cause , [FW-1160], ,, INFO, , , , value has changed(High=, Low=). Current value - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 364
that the number of link failures that the port experiences has troubleshoot them. A low number of link loss errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 365
and, if applicable, troubleshoot them. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1164 Message , [FW-1164], ,, INFO, , , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 366
you continue to experience loss-of-synchronization errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW-1167 Message , [FW-1167], ,, INFO, , , , is between high and low boundaries - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 367
appropriate to the particular policy of the end-user installation. A low number of signal loss errors means that the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], ,, WARNING, , , , is above high boundary(High - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 368
protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1174 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 369
means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1178 Message , [FW-1178], ,, WARNING, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 370
number of invalid cyclic redundancy checks (CRCs) that the port experiences has changed. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent fluctuations in CRC errors generally indicate an aging fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 371
the percentage of incoming traffic that the port experiences has fallen below the low boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 301 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 372
. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1188 Message , [FW-1188], ,, INFO, , , , value has changed(High=, Low=). Current value is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 373
end-user installation. Severity INFO FW-1190 Message , [FW-1190], ,, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 374
, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1194 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 375
appropriate to the particular policy of the end-user installation. A low Action number of link resets means that the switch is functioning normally. Severity INFO FW-1198 Message , [FW-1198], ,, WARNING, , , , is above high boundary(High - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 376
is appropriate to the particular policy of the end-user installation. A Action low number of C3 discard means that the switch is functioning normally. Severity INFO FW-1202 Message , [FW-1202], ,, WARNING, , , , is above high boundaries - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 377
number>,, INFO, , , , is between high and low boundaries (High=, Low=). Current value is . Probable Cause Indicates that the trunk utilization has gone above its threshold level. Recommended No action required. Action Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 378
only large numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. 308 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 379
to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1240 Message Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 380
as is appropriate to the particular policy of the end-user installation. A low number of CRC errors means that the fabric is functioning normally. The CRC error area of the End-to-End Performance Monitor class helps you tune your fabric. To reduce CRC messages, experiment with alternative topologies - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 381
that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 382
messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO 312 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 383
particular policy of the Action end-user installation. Severity INFO FW-1273 Message , [FW-1273], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Fabric OS Message Reference 313 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 384
and Write, SCSI Traffic, or IP commands in a frame. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1274 Message , [FW-1274], ,, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 385
switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user value>). Current value is . Indicates that the number of Telnet violations has changed from a value outside of the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 386
switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user is . Probable Cause Indicates that the number of hypertext transfer protocol (HTTP) violations has fallen below - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 387
is . Probable Cause Indicates that the number of hypertext transfer protocol (HTTP) violations has changed from switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 388
switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user . Probable Cause Indicates that the number of application programming interface (API) violations has changed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 389
command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO FW-1309 Message , [FW-1309], ,, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 390
> . Indicates that the number of simple network management protocol write (WSNMP) violations has risen above the high boundary. WSNMP violations indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. 320 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 391
a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world wide name (WWN). The SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server functionality. Fabric OS Message Reference 321 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 392
that the number of SES violations has risen above the high boundary. SES violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world wide name (WWN). The SES_POLICY contains a list of WWNs of device ports that are - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 393
to security-class messages depend on user policies. Consult your security administrator value is . Indicates that the number of simple network management server (MS) violations has ports that are allowed to access the Management Server functionality. Fabric OS Message Reference 323 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 394
serial port access is enabled. Recommended Action Run the errShow command to determine the WWN of the device that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING 324 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 395
has been received. The SERIAL_POLICY contains a list of switch world wide names (WWNs) for which serial port access is enabled. Recommended No action is required. Action Severity INFO FW-1328 Message , [FW-1328], ,, INFO, , , value has changed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 396
value is . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has changed. SCC violations indicate that an unauthorized switch tried to join the fabric. The SCC_POLICY contains a list of switches by world wide name (WWN) that are allowed to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 397
> . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has fallen below the low boundary. SCC violations indicate that an unauthorized switch tried to join the fabric. The SCC_POLICY contains a list of switches by world wide names (WWNs) that are - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 398
that the number of device cable connection (DCC) violations has changed. DCC violations indicate that an unauthorized device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 399
, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1339 Message , [FW-1339], ,, INFO, , , is between high and low boundaries - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 400
that the number of invalid timestamps has changed. Invalid-timestamp violations indicate that a packet with an invalid timestamp has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the packet - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 401
the number of invalid timestamps has risen above the high boundary. Invalid-timestamp violations indicate a packet with an invalid timestamp has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 402
that the number of invalid signatures has changed. Invalid-signature violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 403
number of invalid signatures has risen above the high boundary. Invalid-signature violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 404
the number of invalid certificates has fallen below the low boundary. This violation indicates that a packet with an invalid certificate has been received from the primary fabric configuration server (FCS). Before a new primary FCS switch sends any configuration data to any switch in the fabric, it - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 405
many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number of authentication failures. Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 406
occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number of authentication failures. Recommended No - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 407
that the number of switch link number of time service (TS) out-of-sync violations has changed. Recommended Responses to security-class messages depend on user number>,, INFO, , , is below low boundary(High=, Low=). Current value is . Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 408
the number of no-FCS violations has changed. This counter records how often the switch loses contact with the primary fabric configuration server (FCS) fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 409
that the number of no-FCS violations has fallen below the low boundary. This counter records how often the switch loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 410
that the number of no-FCS violations has changed from a value outside of the acceptable range to a value within the acceptable range. This counter records how often the switch loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 411
is . Probable Cause Indicates that the number of illegal commands has changed. This counter tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 412
. Probable Cause Indicates that the number of illegal commands has fallen below the low boundary. This counter tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 413
of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1402 Message , [FW-1402], ,, WARNING - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 414
of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1404 Message , [FW-1404], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 415
command. Recommended Replace the missing power supply. Action Severity WARNING FW-1429 Message , [FW-1429], ,, WARNING, , Switch status change contributing factor: Power supplies are not redundant. Fabric OS Message Reference 345 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 416
that the switch status is not in a healthy state. This occurred because the number of faulty world wide name (WWN) cards is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty WWN card. Action Severity WARNING 346 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 417
install the same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 418
command to modify the SFP policy or to add SFPs to the empty Action ports. Severity WARNING FW-1439 Message , [FW-1439], ,, WARNING, , Switch status change contributing factor Switch offline. 348 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 419
the switch is offline. Recommended Run the switchEnable command. Action Severity WARNING FW-1440 Message , [FW-1440], ,, INFO [FW-1443], ,, INFO, , state has changed to . Fabric OS Message Reference 349 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 420
4 power supplies for full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch status is DOWN - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 421
, threshold exceeded: Port disabled. Probable Cause Link failures indicates that the specified port is now disabled because the link on this port had multiple link failures that exceed Fabric Watch threshold on the port. Both physical and hardware can cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 422
and, if applicable, troubleshoot them. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1512 Message , [FW-1512], ,, INFO, , , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 423
that the number of signal losses that the port experiences has changed end-user installation. Frequent loss of signal generally indicates a physical problem. Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty. Severity INFO Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 424
of the Action end-user installation. Severity INFO FW-1520 Message , [FW-1520], ,, INFO, , , , has dropped below upper threshold boundary to in between(High=, Low=). Current value is . 354 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 425
the Action end-user installation. Severity INFO FW-1521 Message , [FW-1521], ,, INFO, , , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 426
. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1525 Message , [FW-1525], ,, INFO, , , , has crossed lower threshold boundary to in between(High=, Low - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 427
Probable Cause Indicates that the number of state changes that the port experiences has changed and crossed lower problems can cause link resets to increase. Recommended Respond to this message as is appropriate to the particular policy of the end-user installation. Action Severity INFO Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 428
and hardware problems can cause link resets to increase. Recommended Respond to this message as is appropriate to the particular policy of the end-user installation. Action Severity INFO FW-1531 Message , [FW-1531], ,, INFO, , , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 429
Respond to this message as it is appropriate to the particular policy of the end-user installation. Action Severity INFO FW-3011 Message , [FW-3011], ,, INFO, , , is below low boundary(High=, Low=). Current value - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 430
Respond to this message as it is appropriate to the particular policy of the end-user installation. Action Severity INFO FW-3015 Message , [FW-3015], ,, INFO, , , is below low boundary(High=, Low=). Current value - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 431
particular policy of the end-user installation. Action Severity INFO FW-3019 Message , [FW-3019], ,, INFO, , , is below low boundary(High=, Low=). Current value is Fabric OS Message Reference 361 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 432
online, or it is testing. Recommended No action is required. Action Severity WARNING FW-3021 Message , [FW-3021], ,, WARNING, , , is below low boundary(High=, Low=). Current value is Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 433
problem persists, replace Action the standby CP. Run the supportSave command and contact your switch service provider. Severity CRITICAL HAM-1002 Message , [HAM-1002], , SLOT cp-slot-number : • Hafailover • Unknown Fabric OS Message Reference 363 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 434
1006], , SLOT cp-slpt-number | FFDC | CHASSIS, FFDC, CRITICAL, ,EMAC controller for Active CP is BAD. Indicates that the local EMAC controller on the active control processor (CP) is BAD as determined by the diagnostic test run by the HAM module. 364 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 435
for recovery. This follows if the event logged in 1007 has happened and auto-reboot is disabled. Recommended Reboot the whole system manually to recover. Run the supportSave command and contact your Action switch service provider. Severity CRITICAL Fabric OS Message Reference 365 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 436
>, [HAM-1012], , SLOT cp-slot-number | CHASSIS, CRITICAL, ,Password database conversion failed. Probable Cause Indicates the password database conversion failed. Recommended No action is required. Action Severity CRITICAL 366 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 437
supportSave command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], , SLOT cp-slot-number | CHASSIS, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 438
number>, SLOT cp-slot-number | CHASSIS, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset that in certain circumstances a CP may experience a double reset and reboot twice in a row. A CP can recover - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 439
switch (for nonbladed switches). Action Severity ERROR HIL-1103 Message , [HIL-1103], ,, ERROR, , Blower - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 440
problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR HIL-1105 Message , [HIL-1105], ,, ERROR, , Switch voltage is faulty, replace the entire switch. Severity ERROR 370 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 441
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. Fabric OS Message Reference 371 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 442
temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the entire switch must be replaced because these switches do not have field-replaceable units (FRUs). Severity ERROR 372 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 443
ERROR, , Fan sensor , speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 444
often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately HIL-1304 Message , [HIL-1304], ,, ERROR, , Two fans failed. 374 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 445
HIL-1308 Message Probable Cause , [HIL-1308], ,, ERROR, , All fans failed. Replace failed fan FRUs immediately. Indicates that all fans have failed. This message is often preceded by a low fan speed message. Fabric OS Message Reference 375 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 446
faulty and non-faulty behavior. Replace the switch because the fan is not field-replaceable. Severity INFO HIL-1401 Message , [HIL-1401], ,, WARNING, , One fan FRU missing. Install fan FRU immediately. 376 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 447
HIL-1404], ,, WARNING, , fan FRUs missing. Install fan FRUs immediately. number>,, WARNING, , Slot , high temperature (). Indicates that the temperature of this blade has risen above the warning threshold. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 448
operational range of your switch. Refer to the hardware reference manual for your switch for the operational number>,, INFO, , System within normal temperature specifications ( C). Indicates that temperatures in the system have returned to normal. 378 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 449
prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 450
the system can continue operation. Recommended Action To help prevent future problems, make sure that all the fans are working properly. Make sure of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity WARNING 380 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 451
/power supply unit number> not supplying power, fan speeds not available. Please ensure that the unit has power and the switch is on. Indicates that the power supply is not connected to a power source or it is not switched on or the unit is faulty. Applicable only to Brocade 5100. Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 452
then switch on Action the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 Message , [HIL-1650], , cards are inserted. Action Severity ERROR 382 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 453
from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch. In the Fabric OS, the HLO dead timeout value is not configurable, so - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 454
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 455
the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 385 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 456
47 HMON-1001 386 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 457
SFP is inserted. Recommended No action is required. Action Severity INFO HSL-1003 Message Probable Cause , [HSL-1003], ,, INFO, , SFP for interface is removed. Indicates an SFP is removed. Fabric OS Message Reference 387 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 458
. Action Severity CRITICAL HSL-1006 Message Probable Cause , [HSL-1006], ,, CRITICAL, , Failed to get kernel page size bytes for mmap. Indicates that there is not enough contiguous kernel memory. 388 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 459
HSL-1007 Message , [HSL-1007], ,, ERROR, , Failed to read SFP for interface . Probable Cause Indicates a failure to read an SFP. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 389 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 460
48 HSL-1007 DRAFT: BROCADE CONFIDENTIAL 390 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 461
on PID format, refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], , AUDIT, INFO, , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 462
49 HTTP-1003 392 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 463
number>: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and slotPowerOn commands. Action Severity ERROR Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 464
50 IBD-1001 394 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 465
>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to log in. Action Severity WARNING Fabric OS Message Reference 395 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 466
51 IBPD-1003 396 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 467
ICPD-1004 Message Probable Cause , [ICPD-1004], ,, WARNING, , iSNS Client service is detected on multiple switches in fabric. Indicates the iSNS Client service is enabled on multiple switches in the fabric. Fabric OS Message Reference 397 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 468
Client service on a single switch in the fabric using the fosConfig command. Refer Action to the Fabric OS Command Reference for more information on this command. Severity WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, , iSCSI configuration between - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 469
Recommended No action is required. Action Severity INFO 52 ICPD-1008 Fabric OS Message Reference 399 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 470
52 ICPD-1008 400 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 471
> . Probable Cause Indicates that a change in the gateway IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the source of the address change is the dynamic host configuration protocol (DHCP - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 472
53 IPAD-1001 402 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 473
the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is () Fabric OS Message Reference 403 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 474
, [IPS-1006], ,, WARNING, , Tunnel Configuration Mismatch for slot () port() tunnel ID() reason () Probable Cause Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The reason - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 475
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 476
55 ISCS-1000 406 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 477
system-name>, Configuration peering with external iSNS server slot/port /ge (current /ge). Probable Cause Indicates that the user has issued - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 478
], ,, INFO, , Peering with external iSNS server not started because configuration unchanged. Indicates that peering with the external internet storage name service (iSNS) server was already started with the same configuration. 408 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 479
No action is required. Use the fosConfig command to display, enable, or disable the iSNS client Action service. Severity INFO ISNS-1013 Message , [ISNS-1013], ,, WARNING, , iSNS server connection failure. Fabric OS Message Reference 409 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 480
iSNS server on management port. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) on the management port. Recommended No action is required. Action Severity INFO 410 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 481
Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1006 Message , [KAC-1006], ,, ERROR, , Switch to key vault - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 482
configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1008 Message , [KAC-1008], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 483
switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , switch has ended unexpectedly. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 484
58 KSWD-1002 414 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 485
No action is required. Action Severity ERROR KTRC-1004 Message Probable Cause , [KTRC-1004], ,, ERROR, , Cannot write to ATA dump device Indicates the write boundary in the ATA dump device has exceeded. Fabric OS Message Reference 415 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 486
[KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to initialize. Recommended No action is required. Action Severity ERROR 416 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 487
. Probable Cause Indicates that the l2sys encountered with System Service Manager (SSM) message queue errors. Recommended Restart the number>,, ERROR, , FDB error: Error in creating AVL tree. Indicates that the l2sys has encountered an error while initializing the AVL tree. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 488
-number>,, INFO, , MMac-address-table on slot chip is less than 90 percent full. Probable Cause Indicates that the mac-address-table is less than 90% full. Recommended No action is required. L2SYS will start learning the entries. Action Severity INFO 418 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 489
initialization of a module within the LACP daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR Fabric OS Message Reference 419 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 490
61 LACP-1001 DRAFT: BROCADE CONFIDENTIAL 420 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 491
[LANCE-1000], ,, ERROR, , Slot Port GE : Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the port is disabled. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 421 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 492
62 LANCE-1000 422 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 493
Logical Fabric Manager service is enabled by the factory setting and it is not user configurable. Recommended No action is required. Action Severity INFO LFM-1003 Message , [LFM-1003], ,, INFO, , The Logical Fabric Manager configuration is set to default - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 494
the port disable using the Action switchshow command. Rectify the disable based on the reason. Severity WARNING LFM-1006 Message , [LFM-1006], ,, WARNING, , The switch with domain with firmware version has joined the FID fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 495
>, [LOG-1001], , FFDC, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 496
64 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 426 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 497
link state record when first enabled. By disabling and enabling the switch, a new local link state record is generated. Recommended Run the switchDisable and switchEnable commands. A new local link state record is generated Action during the switch enable. Fabric OS Message Reference 427 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 498
>, [LSDB-1004], ,, WARNING, , No Link State Record for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD once the fabric is stable. Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 499
by the host or if Action default values are desired for the switch node descriptor fields. Severity INFO MFIC-1003 Message Probable Cause , [MFIC-1003], ,, WARNING, , Effective Insistent domain ID for the fabric changed from to Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 500
66 MFIC-1003 Recommended Action IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. If you are enabling or disabling IDID mode, this message is for information purposes only, and no action is required. IDID mode can - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 501
is required. Action Severity ERROR MPTH-1003 Message , [MPTH-1003], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 431 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 502
67 MPTH-1003 432 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 503
68 MQ-1004 Message , [MQ-1004], ,, ERROR, , mqRead, queue = - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 504
68 MQ-1004 434 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 505
Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Restart or power cycle the switch. Action Severity WARNING MS-1002 Message , [MS-1002 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 506
by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4 and contact your switch service provider. Severity INFO MS-1004 Message , [MS-1004], ,, INFO, < - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 507
neither response, which violates the Fibre Channel Generic Services (FS-GS) specification. Recommended Check the integrity of the FC switch at the specified domain. It and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, < - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 508
69 MS-1009 MS-1009 Message , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . . Probable Cause Indicates a registered link incident record (RLIR) has been generated for one of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 509
, [MS-1025], ,, WARNING, , Possible Failover could have occurred while enabling MS Platform Service. Probable Cause Indicates that while the MS Platform Service was being enabled, a failover has occurred. This can leave the fabric in an inconsistent state - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 510
69 MS-1025 440 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 511
error. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 512
Recommended No action is required Action Severity INFO MSTP-2002 Message , [MSTP-2002], ,, INFO, , . My Bridge ID: Old Root: No action is required. Action Severity INFO 442 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 513
implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored. Otherwise, run the portDisable and portEnable commands to refresh the port. Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 514
-number>,, WARNING, , DB_XMIT_SET flag not set in state , input , port Database Wait • 5 - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity WARNING 444 Fabric OS Message Reference 53- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 515
-number>,, WARNING, , Remote switch 0x has firmware revision lower than 2.2: which is not supported! Probable Cause Indicates the local switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 516
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 517
72 NS-1007 NS-1007 Message , [NS-1007], ,, WARNING, , NS has detected a logical ISL port in TI zone in fabric . Routing may not be setup correctly. Probable Cause Indicates that a logical ISL is detected in the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 518
72 NS-1007 448 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 519
link is up. Action Severity INFO NSM-1004 Message Probable Cause , [NSM-1004], ,, INFO, , Creating a Port-Channel interface . Indicates that the new Portchannel interface has been created. Fabric OS Message Reference 449 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 520
the chassis is disabled or enabled. Recommended No action is required. Action Severity INFO NSM-1008 Message , [NSM-1008], ,, INFO, , Blade . Probable Cause Indicates the blade is disabled or enabled. 450 Fabric OS Message Reference 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 521
DRAFT: BROCADE CONFIDENTIAL 73 NSM-1008 Recommended No action is required. Action Severity INFO Fabric OS Message Reference 451 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 522
73 NSM-1008 DRAFT: BROCADE CONFIDENTIAL 452 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 523
1003 Message , [ONMD-1003], ,, INFO, , The feature is disabled: . Probable Cause Indicates a specific feature is disabled. Recommended Change the feature's setting to the "enable" state. Action Severity INFO Fabric OS Message Reference 453 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 524
74 ONMD-1003 DRAFT: BROCADE CONFIDENTIAL 454 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 525
configuration file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 526
; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1006 Message , [PDM-1006], ,, WARNING, , Too many files in sync.conf. Probable Cause Indicates the configuration file sync.conf contains too many entries - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 527
Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference 457 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 528
; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1013 Message , [PDM-1013], ,, WARNING, , File empty: Probable Cause Indicates the switch configuration file /etc/fabos/fabos.[0|1].conf is empty - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 529
Use path names not exceeding 49 characters in length for the files to be replicated. Action Severity WARNING PDM-1021 Message , [PDM-1021], ,, WARNING, , Failed to download area port map. Fabric OS Message Reference 459 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 530
service provider. Severity WARNING PDM-1022 Message , [PDM-1022], ,, WARNING, , The switch is configured only with IPv6. Probable Cause Indicates that the parity data manager (PDM) cannot synchronize with its peer because the firmware does not support - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 531
, [PDTR-1001], ,, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 532
76 PDTR-1002 462 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 533
the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message , [PLAT-1001], ,, INFO, , CP resetting other CP (double reset may occur). Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 534
> Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected. Recommended The FRU must be replaced. Action Severity CRITICAL 464 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 535
INFO PMGR-1004 Message Probable Cause , [PMGR-1004], , WARNING, ,Attempt to create switch failed. Error message: . Indicates that the switch with the specified FID was not deleted. Fabric OS Message Reference 465 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 536
], , WARNING, , Attempt to move port(s) on slot to switch number>, WARNING, ,Attempt to change switch to switch failed. Error message: . Indicates the failed attempt to change the switch FID. 466 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 537
, [PMGR-1011], , INFO, , Attempt to move ports to switch succeeded. Probable Cause Indicates the successful attempt to move the ports to the specified switch. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 467 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 538
78 PMGR-1011 468 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 539
to be enabled. Severity INFO PORT-1005 Message Probable Cause , [PORT-1005], ,, WARNING, , Slot port does not support configured L_port. Issue portCfgLport to clear configuration. Indicates the specified port is configured to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 540
a GbE port has been enabled. Recommended No action is required. Action Severity INFO PORT-1009 Message Probable Cause , [PORT-1009], ,, INFO, , GigE Port (ID: ) has been disabled. Indicates a GbE port has been disabled. 470 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 541
-name>, Port (ID: ) QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be disabled on a 4G or 8G long distance platform. Recommended This is normal; no action required. Action Severity WARNING Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 542
79 PORT-1010 472 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 543
>, [PS-1001], ,, INFO, , Advanced Performance Monitoring configuration updated due to change in PID format Probable Cause Indicates the PID format was changed. Recommended No action is required. Refer to the Fabric OS Administrator's Guide for more information on the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 544
that the restoring configuration has failed to set the end-to-end monitoring mask on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only be disabled through the Fabric Access API - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 545
. Action Severity INFO PSWP-1002 Message , [PSWP-1002], ,, INFO, , Port Swap feature enabled. Probable Cause Indicates that the portSwap feature has been enabled in the switch. Recommended No action is required. Action Severity INFO PSWP-1003 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 546
fabosInit.>in switch number . Probable Cause Indicates that the bladeSwap command has failed to access the switch context. Recommended Retry the command. If the failure persists, contact your support representative. Action Severity WARNING 476 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 547
81 PSWP-1007 Fabric OS Message Reference 477 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 548
81 PSWP-1007 478 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 549
software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1005 Message , [RAS-1005], , FFDC, WARNING, , Software 'assert' error detected. Fabric OS Message Reference 479 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 550
by user> '. Probable Cause Indicates that the support data file is transferred from the switch automatically. Recommended No action is required. Action Severity INFO RAS-2001 Message , [RAS-2001], , INFO, , Audit message log is enabled. Probable - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 551
, INFO, , USB storage device enabled. Probable Cause Indicates that the USB storage device is enabled. Recommended No ], , INFO, , USB storage device disabled. Indicates that the USB storage device is disabled. Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 552
82 RAS-3004 Recommended No action is required. Action Severity INFO 482 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 553
the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled. Probable Cause Indicates that the RCS feature has been enabled. RCS must be capable on all switches in the fabric to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 554
RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.1 and later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 555
83 RCS-1007 Severity INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 556
83 RCS-1008 486 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 557
String>.\n No response from cluster member WWN: Slot: . Probable Cause Indicates that a First time encryption/re-key/Write Metadata was not started . Recommended Correct the error and resume. Action Severity CRITICAL Fabric OS Message Reference 487 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 558
84 RKD-1004 RKD-1004 Message , [RKD-1004], ,, INFO, , Message: the generic rekey message. Recommended No action is required. Action Severity INFO 488 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 559
Chapter 85 RMON-1001 Message , [RMON-1001], ,, INFO, , RMON rising threshold alarm from SNMP OID . Action Severity INFO RMON-1002 Message , [RMON-1002], ,, INFO, , RMON falling threshold alarm from SNMP OID - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 560
85 RMON-1002 DRAFT: BROCADE CONFIDENTIAL 490 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 561
error was reported. The specified client IP address has faulty credentials. Recommended Enter the correct user name and password from the Fabric Access API host. Action Severity WARNING RPCD-1002 Message , [RPCD-1002], ,, WARNING, , Missing certificate - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 562
Indicates the SSL certificate file has been corrupted. Recommended To enable RPCD in Secure mode, install a valid SSL certificate in the switch. Action Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing private key file. Secure RPCd - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 563
domain ID is online. Enable the switch with the specified domain ID. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity WARNING Fabric OS Message Reference 493 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 564
ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity INFO 494 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 565
1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command . Recommended Retry the command. Action Severity ERROR Fabric OS Message Reference 495 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 566
88 SAS-1001 496 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 567
daemon name is full. This might be listing, see the Introduction to this manual. • fabricd • asd • evmd switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 568
89 SCN-1001 498 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 569
switch service provider. Severity ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: . Probable Cause Indicates that the receiving switch fails to validate the security database sent from the primary fabric configuration - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 570
command and contact your switch service provider. Severity WARNING SEC-1005 Message , [SEC-1005], ,, INFO, , Primary FCS receives data request from domain Probable Cause Indicates the primary fabric configuration server (FCS) received - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 571
], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish SSH connection. Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 572
key infrastructure (PKI) objects exist on the switch. If the private key does not exist, follow the steps for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is invalid, install the certificate by following the field upgrade process - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 573
[SEC-1026], ,, ERROR, , Invalid format or character in switch member . Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 574
sequence-number>, ERROR, , The length of the name invalid. Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 575
supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch connection control (SCC) policy. Refer to the Fabric ], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 576
reasons: • The value is not a number. • The value is too long. Valid numbers must be between one and three characters long. • The value cannot be parsed due to invalid characters. Recommended Use valid syntax when entering the port members. Action 506 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 577
sequence-number>,, ERROR, , Too many port members. Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 578
, [SEC-1049], ,, ERROR, , Invalid switch name . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 579
Missing brace for port list . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 580
members in list. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 581
a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 582
install the certificate by following the field upgrade process. Severity ERROR SEC-1065 Message , [SEC-1065], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 583
Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 584
in the zone. Recommended Re-enable the current zone configuration for the change to take effect. Action Severity ERROR SEC-1077 Message , [SEC-1077], ,, ERROR, , Failed to activate new policy set on all switches. Probable Cause Indicates the policy - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 585
when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation be correctly updated for that specific switch. Severity ERROR SEC-1081 Message , [SEC-1081], ,, ERROR, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 586
sequence-number>,, ERROR, , Name already exists. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 587
than can be distributed to some of the switches in the fabric. Recommended Reduce the number of entries in the security policies to only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 588
-number>,, ERROR, , Name not found. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 589
-number>,, ERROR, , Policy member not found. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 590
timestamp>, [SEC-1099], ,, ERROR, , Please enable your switch before running secModeEnable. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 591
-1101 Message , [SEC-1101], ,, ERROR, , Failed to enable security on all switches. Please retry later. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric are busy. Recommended Action Verify that - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 592
-number>,, INFO, , Stamp is 0. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 593
-number>,, ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Indicates that either a security policy download is attempted with an active policy that does not have the fabric configurations server - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 594
], ,, ERROR, , No primary FCS to failover. Probable Cause Indicates that during an attempted secFcsFailover, no primary fabric configurations server (FCS) is present in the fabric. Recommended Run the secFabricShow command to verify that all switches in fabric are in - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 595
-1117], ,, INFO, , Fail to set . Probable Cause Indicates the switch failed to save the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 596
90 SEC-1121 SEC-1121 Message , [SEC-1121], ,, ERROR, , Time is out of range when . Probable Cause Indicates the time on the switch is not synchronized with the primary fabric configuration server (FCS), the data packet is corrupted, or a replay - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 597
[SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates an sequence-number>,, INFO, , Secure fabric version stamp has been reset. Probable Cause Indicates the version stamp of the secure fabric is reset. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 598
Message , [SEC-1138], ,, INFO, , Security database download received from Primary FCS. Probable Cause Indicates that a non-primary fabric configuration server (FCS) switch received a security database download. Recommended Action Verify that the security - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 599
fabric configuration server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service 1145], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 600
-number>,, INFO, , Error in RCA: RCS is not supported Probable Cause Indicates that reliable commit service (RCS) is not supported. Recommended Action Run the rcsInfoShow command to view RCS capability on the fabric. RCS must be capable on all switches in the fabric to be enabled - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 601
timestamp>, [SEC-1158], ,, INFO, , Invalid name . Probable Cause Indicates the specified name is invalid. The name can be a policy name or a switch name. Recommended Enter a valid name. Action Severity INFO Fabric OS Message Reference 531 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 602
Message , [SEC-1164], ,, ERROR, , Lockdown option cannot be applied on a non-FCS switch. Probable Cause Indicates the attempt to enable security is made on a switch that is not present in the fabric configuration server (FCS) list. Recommended Add the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 603
[SEC-1165], ,, ERROR, , Low memory, failed to enable security on all switches. Probable Cause Indicates the occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 604
-number>,, INFO, , This command must be executed on the Primary FCS switch, the first reachable switch in the FCS list. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 605
SEC-1173 Message , [SEC-1173], ,, ERROR, , Lost contact with Primary FCS switch. Probable Cause Indicates the switch has lost contact with the primary fabric configuration server (FCS) switch in the secure fabric. This could be due to the primary FCS being - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 606
[SEC-1181], ,, INFO, , Deleted account Probable Cause Indicates number>,, ERROR, , Policy to binary conversion error: Port is out range. Indicates a security database conversion has failed because of an invalid value. 536 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 607
Cause Indicates the remote authentication dial-in user service (RADIUS/LDAP) configuration was enabled or disabled as the primary authentication, accounting, and authorization (AAA) mechanism. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 537 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 608
> tries to FLOGI to index/area of switch . Probable Cause Indicates a device connection control (DCC) security violation was reported. The specified device attempted to login using fabric login (FLOGI) to an unauthorized port. The DCC policy correlates specific devices to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 609
login failed. Recommended Use the correct password. Action Severity INFO SEC-1193 Message , [SEC-1193], ,, INFO, , Security violation: Login failure attempt via . IP Addr: Fabric OS Message Reference 539 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 610
names. Probable Cause Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on the switch that reported the warning and retry Action enabling security. 540 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 611
to access your fabric. Take appropriate action, as defined by your enterprise security policy. Severity INFO SEC-1199 Message , [SEC-1199], ,, INFO, , Security violation: Unauthorized access to serial port of switch . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 612
reported. An MS device operation occurred on a non-primary fabric configuration server (FCS) switch. Recommended Action Check the management server policy and verify the connection is allowed. If the connection is allowed but not specified, enable the connection in the MS policy. If the MS policy - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 613
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Fabric OS Message Reference 543 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 614
software version does not support the Brocade Secure Fabric OS feature. Recommended Run the firmwareDownload command to update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature. Severity INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 615
, [SEC-1304], ,, INFO, , This switch has no security license. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 616
in user Action service (RADIUS) servers, and the servers are correctly configured. Severity INFO SEC-1309 Message , [SEC-1309], ,, INFO, , Waiting for RCS transaction to complete: secs Probable Cause Indicates that Secure Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 617
SEC-1311], ,, ERROR, , Security mode cannot be enabled because one or more of the password policies is not set to default value. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric have password policies that are - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 618
this error. If the problem persists contact your switch service provider. Action Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command failed - dbs configured for rejection on this - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 619
,, ERROR, , Failed secure mode enable command. Reason: . Probable Cause Indicates the security enable failed on the fabric because the switch has a conflicting configuration such as fabric wide consistency configuration or AD configuration. Recommended Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 620
, , Security enforcement: Switch connecting to port is not authorized to stay in fabric. Indicates that because of a switch connection control (SCC) policy violation, the switch is being disabled on the specified port. 550 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 621
attempt to join the switch with the fabric. Severity ERROR SEC-1326 Message , [SEC-1326], ,, INFO, , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to . Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 622
correct the configuration if necessary. Severity ERROR SEC-1331 Message , [SEC-1331], ,, ERROR, , Attempt to enable secure mode failed. Reason: . Probable Cause Indicates the secModeEnable command failed on the fabric because default IP Filter - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 623
[SEC-1333], ,, INFO, , command failed. There are VF enabled switches in fabric. , [SEC-3035], , AUDIT, INFO, , Event: ipfilter, Status: success, Info: ipfilter policy(ies - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 624
, Info: Unauthorized host with IP address tries to establish connection using . Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. 554 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 625
SEC-3051 Message , [SEC-3051], , AUDIT, INFO, , The license key is . Probable Cause Indicates that a license key is added or removed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 555 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 626
90 SEC-3051 556 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 627
Cause Indicates the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Verify the IP address for the Ethernet and Fibre Channel interface is set correctly. If the specified Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 628
protocol (SNMP) configuration group was reset to the factory default. Recommended Execute the snmpConfig --show for the group to see the new configuration. Action Severity INFO SNMP-1007 Message , [SNMP-1007], ,, INFO, , The last fabric change happened - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 629
, [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow command to view the current device status. Action Severity INFO Fabric OS Message Reference 559 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 630
91 SNMP-1008 560 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 631
number>,, INFO, , , Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled perform a fastboot command on the switch to recover the system. Severity ERROR Fabric OS Message Reference 561 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 632
[SPC-2004], ,, ERROR, , , : FPGA firmware download failed: 0x%x. Probable Cause Indicates the FPGA download has failed. Recommended No action is required. Action Severity ERROR 562 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 633
2005 SPC-2005 Message , [SPC-2005], ,, INFO, , , : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended No action is required. Action Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 634
-number>,, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 635
ERROR SPC-3004 Message , [SPC-3004], ,, ERROR, , , : No output KEK for DEK create, KEK: . Fabric OS Message Reference 565 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 636
ERROR SPC-3005 Message , [SPC-3005], ,, ERROR, , , :DEK inject error: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 637
For status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC-3008 Message , [SPC-3008], ,, INFO, , , : SP crypto got READY notification - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 638
, [SPC-3013], ,, ERROR, , , : SEK generation failure: . Indicates the Crypto Module internal Secret Encryption Key could not be generated. 568 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 639
, , , : RSA pairwise key generation test failure. Probable Cause Indicates the Crypto Module could not generate its internal key pair. Recommended Contact technical support. Action Severity ERROR Fabric OS Message Reference 569 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 640
92 SPC-3015 570 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 641
. Action Severity WARNING SPM-1003 Message , [SPM-1003], ,, INFO, , Set New Group Cfg SC Enable KV Type . Probable Cause Indicates a new group has been configured. Recommended No action is required. Action Severity INFO SPM-1004 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 642
slot configuration. Recommended No action is required. Action Severity INFO SPM-1006 Message , [SPM-1006], ,, INFO ,, INFO, , Deregistered SP Certificate in slot . Indicates an SP certificate de-registration. 572 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 643
that a group configuration has changed the quorum size. Recommended No action is required. Action Severity INFO SPM-1012 Message Probable Cause , [SPM-1012], ,, INFO, , Authentication Context:. Indicates an authentication context. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 644
is required. Action Severity INFO SPM-3004 Message Probable Cause , [SPM-3004], ,, INFO, ,Event: cryptocfg Status: success, Info: EE in slot enabled. Indicates an encryption engine was enabled. 574 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 645
INFO SPM-3008 Message Probable Cause , [SPM-3008], ,, INFO, ,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Indicates a DH challenge was generated for a key vault. Fabric OS Message Reference 575 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 646
-3012], ,, INFO, ,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Indicates a key vault was registered. 576 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 647
Action Severity INFO SPM-3015 Message , [SPM-3015], ,, INFO, ,Event: cryptocfg Status: success, Info: ,, INFO, ,Event: cryptocfg Status: success, Info: Master key generated. Indicates a master key was generated. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 648
SPM-3020 Message Probable Cause , [SPM-3020], ,, INFO, ,Event: cryptocfg Status: success, Info: System card with certificate label \"\" deregistered. Indicates a system card was de-registered. 578 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 649
was enabled or disabled. Recommended No action is required. Action Severity INFO SPM-3024 Message Probable Cause , [SPM-3024], ,, INFO, ,Event: cryptocfg Status: success, Info: Quorum size set to . Indicates the quorum size was set. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 650
-number>,, INFO, ,Event: cryptocfg Status: success, Info: Recovery card registered. Certificate label: \"\" Certificate file: \"\". Probable Cause Indicates a recovery card was registered. Recommended No action is required. Action Severity INFO 580 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 651
-number>,, INFO, , supportSave has stored support information to the USB storage device. Probable Cause Indicates the supportSave command was used to transfer support information to an attached USB storage device. Recommended No action is required. Action Severity INFO Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 652
SS-1003 SS-1003 Message , [SS-1003], ,, WARNING, , supportSave's operation to USB storage storage device settings. After the USB problem is Action corrected, rerun the supportSave command. Severity WARNING 582 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 653
the switch using the memShow command. Restart or power cycle the switch. Severity ERROR SSMD-1002 Message , [SSMD-1002], ,, Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 654
startup and initialization. Recommended Action Restart or power cycle the switch .If the condition persists then download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR SSMD-1200 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 655
Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the CEE Map ETS feature. Recommended Delete and reapply the CEE Map ETS policy. Restart or power cycle the switch. Action Fabric OS Message Reference 585 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 656
. Restart or power cycle the switch. Action Severity WARNING SSMD-1207 Message , [SSMD-1207], ,, WARNING, ,QoS failed programming interface 0x x Default CoS. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 657
Control policy. Restart or power cycle the switch. Action Severity WARNING SSMD-1213 Message , [SSMD-1213], ,, WARNING, ,QoS failed programming interface 0x x CoS Tail Drop Threshold. Fabric OS Message Reference 587 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 658
the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Pause feature. Recommended Delete and reapply the QoS Pause policy. Restart or power cycle the switch. Action Severity WARNING 588 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 659
, [SSMD-1217], ,, WARNING, ,QoS CEE could not comply with FCoE scheduler policy for CEE Map . Probable Cause Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE configuration into an ETS scheduler policy - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 660
95 SSMD-1217 DRAFT: BROCADE CONFIDENTIAL 590 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 661
SULB-1002 Message , [SULB-1002],, AUDIT, INFO, , Firmwaredownload command has completed successfully. Probable Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 662
1005 Message , [SULB-1005], ,, INFO, , Current Active CP firmware. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. Severity INFO 592 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 663
[SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Probable Cause Indicates the failed because firmwareDownload is already in progress." "Sanity check failed because FABRIC OS is disabled on Standby CP." "Sanity check failed because HAMD is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 664
Standby CP failed to boot up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." "firmwareDownload has started on 0x77 0x78 0x79 0x7a 0x7b 0x7c 0x7d 594 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 665
has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry firmwareDownload." 0xa6 "firmwareCommit has started on the blade. This may take up to 10 minutes." 0xa7 Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 666
is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 667
on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two feature releases (a feature release is indicated by a major number and a minor number, for example, X.Y). The following are major upgrade versions for the Fabric OS: v4 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 668
- The pre-install script failed. switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware commit operation. Wait until this operation completes (about 10 minutes) before attempting another firmwareDownload. 598 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 669
active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message , [SULB-1010], , AUDIT, INFO, , Firmwarecommit - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 670
another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is being downloaded to the blade in slot . Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 671
to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], AUDIT, WARNING, , Firmware commit has completed on the blade in slot . Probable Cause Indicates the firmwareCommit - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 672
progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. Indicates the switch has rebooted with the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 673
to monitor the progress. If the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message , [SULB-1035], , AUDIT, ERROR, , An error has occurred during relocation of the internal image. Fabric OS Message Reference 603 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 674
relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1036 Message , [SULB-1036], ,, INFO, , . Probable Cause Indicates the firmware version is running in the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 675
the supportSave command and contact your switch service provider. Severity ERROR SWCH-1002 Message , [SWCH-1002], ,, INFO, , Security violation: Unauthorized device tries to flogin to port . Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 676
into the fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload Action command. Severity WARNING SWCH-1007 Message Probable Cause , [SWCH-1007], ,, WARNING, , Switch port disabled - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 677
blade is enabled with the port configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap the ports back to the ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 678
functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity WARNING SWCH-1012 Message , [SWCH-1012], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 679
on the Loop device. Recommended Action This is a LOOP device and Peristent PID is set on it, This is not a supported configuration. Remove the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn command. Severity INFO Fabric OS Message Reference 609 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 680
as persistent PID is set on device and port has user area bound to it. Probable Cause support links to AG running QOS. Recommended Load a firmware version on the standby CP that supports QOS links to AG, using the Action firmwareDownload command. Severity WARNING 610 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 681
to change chassis configuration> Indicates that on system startup, the option configuration file corresponding to the chassisConfig option read could not be found. This indicates that option is not supported on this platform running this version of the firmware. Fabric OS Message Reference 611 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 682
platforms running any valid firmware. Severity CRITICAL SYSC-1004 Message , [SYSC-1004], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 683
run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM-1002], ,, INFO, , , Switch: Probable Cause Indicates a user has executed either the switchShutdown or switchReboot - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 684
99 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Verify that the world - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 685
-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended No action is required. Action Severity INFO Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 686
10 TAPE-1001 616 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 687
message trigger setup using the traceTrig command. Recommended Run the supportFtp command to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity WARNING TRCE-1002 Message , [TRCE-1002], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 688
Action command and contact your switch service provider. Severity ERROR TRCE-1006 Message , [TRCE-1006], ,, INFO, , FTP Connectivity Test succeeded to FTP site ' '. Probable Cause Indicates that a connectivity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 689
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1010 Message , [TRCE-1010], ,, ERROR, , Traced fails to start Fabric OS Message Reference 619 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 690
the main system and the indicated slot is unavailable. Recommended Make sure the blade is enabled and retry the command. If the blade is already enabled, run the Action supportSave command and contact your switch service provider. Severity WARNING 620 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 691
occurs if the user name or password is incorrect. Recommended Action This message indicates a typing error by the user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 692
Run the configShow command to view the configuration file. Action Severity INFO TRCK-1005 Message , [TRCK-1005], ,, INFO, , Track-changes on. Probable Cause Indicates the track change feature has been enabled. Recommended No action is required. Run the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 693
FCS switch has the clock server IP configured correctly. Verify this clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL. Severity INFO Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 694
TS-1007 Message , [TS-1007], ,, WARNING, , . Probable Cause Indicates a switch is trying to set the tsclockserver, which is not the primary fabric configuration server (FCS) across the fabric. A consistent FCS policy must be implemented across the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 695
10 TS-1008 Fabric OS Message Reference 625 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 696
10 TS-1008 626 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 697
Port = , should be Probable Cause Indicates the switch detected an inconsistency in the routing database between the routing protocol and the hardware configuration. The first port number displayed is what the hardware has configured and the second port number displayed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 698
10 UCST-1025 UCST-1025 Message , [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 699
zone is not compatible with the fabric configuration. Probable Cause Indicates the specified switch is unreachable because of the TI zone and the fabric configuration incompatibility. Recommended Clear all TI zones and refer to the TI zone user manual for instructions on how to create a valid TI - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 700
10 UPTH-1002 630 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 701
file is either invalid or absent. Recommended Install a valid key file. Action Severity WARNING WEBD-1002 Message , [WEBD-1002], ,, WARNING, , Missing or Invalid Key file -- HTTPS is configured but could not be started. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 702
restore HTTP services. The problem often results from invalid configuration of SSL certificates, but there can be more than one reason for such a failure. Recommended Verify the certification file because there may be a mismatch involved. Action Severity WARNING 632 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 703
your customer support for Action assistance. Severity ERROR XTUN-1003 Message , [XTUN-1003], ,, ERROR, , Message Transmission failed:I/T/L: . Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 704
event, contact your customer support for Action assistance. Severity WARNING XTUN-2000 Message Probable Cause , [XTUN-2000], ,, INFO, , FCIP Tunnel UP. Indicates that the specified FCIP tunnel is up. 634 Fabric OS Message Reference 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 705
INFO, , FCIP Tunnel Pri QoS UP. Indicates that the specified quality of service for this tunnel is up. This applies to the data classes only. When the f-class comes online, the tunnel itself is marked as up. Fabric OS Message Reference 635 53-1001338 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 706
-2005], ,, INFO, , FCIP Tunnel Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. error or Action disruption has occurred. Severity INFO 636 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 707
sequence-number>,, ERROR, , Port port ports. Recommended Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have Action deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable if necessary. Severity ERROR Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 708
10 ZEUS-1001 DRAFT: BROCADE CONFIDENTIAL 638 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 709
Messages Chapter 109 ZOLB-1001 Message , [ZOLB-1001], ,, ERROR, , ZONELIB Probable Cause Indicates there to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 639 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 710
10 ZOLB-1001 640 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 711
database and change the port number to a viable value in the effective configuration. Action Severity WARNING ZONE-1004 Message , [ZONE-1004], ,, INFO, , port () enforcement changed to Session Based HARD Zoning. Probable - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 712
port. Severity WARNING ZONE-1013 Message , [ZONE-1013], ,, WARNING, , Quick Loop not supported. Probable Cause Indicates the QuickLoop feature is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 713
supported in Fabric OS v4.x and above. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR ZONE-1019 Message , [ZONE-1019], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 714
was done on purpose. If the new effective zone configuration Action is correct, no action is necessary. Severity INFO ZONE-1023 Message , [ZONE-1023], ,, INFO, , Switch connected to port () is busy. Retry zone merge. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 715
limit for the specific switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. Severity WARNING ZONE-1029 Message Probable Cause , [ZONE-1029], ,, WARNING, , Restoring - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 716
requested format. Severity WARNING ZONE-1031 Message , [ZONE-1031], ,, ERROR, , Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is set to interop mode using the interopMode command. Interop mode does - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 717
,, ERROR, , Unable to examine : error message . Probable Cause Indicates the Fabric OS cannot examine the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 718
>, [ZONE-1040], ,, INFO, , Merged zone database exceeds limit. Probable Cause Indicates the Fabric OS cannot read the merged zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 719
change was done on purpose. If no effective zone configuration Action is needed, no action is necessary. Severity INFO ZONE-1043 Message , [ZONE-1043], ,, INFO, , The Default Zone access mode is set to No Access. Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 720
-1047 Message , [ZONE-1047], ,, INFO, , Switch domain () does not support defined database. Probable Cause Indicates a remote Brocade switch is running a downlevel version of Fabric OS that does not support the defined database. Recommended It is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 721
ZONE-1052 Message , [ZONE-1052], ,, INFO, , The Interop Default Zone state is set to enabled. Probable Cause Indicates the Interop Default Zone attribute state is enabled. Recommended Verify if the Interop Default Zone attribute state change was done on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 722
the defzone command to no access mode. Action Severity WARNING ZONE-1055 Message , [ZONE-1055], ,, WARNING, , McDATA default zone enabled with Frame Redirection zones. Probable Cause Indicates that frame redirection will not function properly with McDATA - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 723
667 •AUDIT FICU System Messages 669 •AUDIT FW System Messages 671 •AUDIT HTTP System Messages 673 •AUDIT IPAD System Messages 675 •AUDIT PORT System Messages 677 •AUDIT SEC System Messages 679 •AUDIT SNMP System Messages 695 •AUDIT SULB System Messages 697 •AUDIT SWCH System Messages 709 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 724
- HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 725
Indicates that the F_Ports mapped to an N_Port have changed and the config file has been updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 655 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 726
11 AG-1029 656 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 727
timestamp>, [AN-1003], ,, WARNING, , Slot , port is a latency bottleneck due the attached device is slow in responding to frames going out of this port. This latency may be inherent in the device or due to heavy workload - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 728
11 AN-1003 658 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 729
has been changed from [] to []. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type can be either "authentication type", No action is required. Action Severity INFO Fabric OS Message Reference 659 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 730
specified port is off, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch the supportSave command and contact your switch service provider. Severity INFO 660 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 731
the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , [AUTH-3008], INFO, SECURITY, , , , Event: , Status: failed, Info: Port has been disabled due to authentication - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 732
11 AUTH-3008 662 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 733
, [BLS-1003], ,, INFO, , An IPsec/IKE policy was deleted. Probable Cause Indicates that an IPsec or IKE policy was deleted and the configuration file was updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 663 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 734
11 BLS-1003 664 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 735
configDownload process was initiated and completed successfully. The message string describes the class of configuration parameters that were downloaded. If admin domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity INFO CONF - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 736
11 CONF-1022 666 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 737
deleted. Probable Cause Indicates that an IPsec/IKE policy was deleted and the config file was updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 667 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 738
11 FCIP-1003 668 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 739
>, , , FMS mode has been enabled. Probable Cause Indicates that the FICON Management server mode has been enabled. Recommended No action is required. Action Severity INFO Recommended No action is required. Action Severity INFO Fabric OS Message Reference 669 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 740
11 FICU-1012 670 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 741
, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 671 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 742
11 FW-3001 672 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 743
event-initiator-details>, , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has defined by your enterprise security policy. Severity INFO Fabric OS Message Reference 673 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 744
12 HTTP-1003 674 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 745
], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 675 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 746
12 IPAD-1002 676 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 747
been enabled. Probable Cause Indicates a GigE port has been enabled. Recommended No action is required. Action Severity INFO PORT-1009 Message AUDIT, , [PORT-1009], INFO, CFG, , , , GigE Port (ID: ) has been disabled. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 748
12 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 678 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 749
Action Severity WARNING SEC-1114 Message , [SEC-1114], ,, WARNING, , [ license ] mode on the fabric. Probable Cause Indicates the security mode of the fabric was either enabled or disabled. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 750
can be one of the following: • There has been an fabric configurations server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify the security event was planned - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 751
success, Info: Removed members from policy . Probable Cause Indicates a user has removed the specific members from the specified security policy. Note: If you use a by your enterprise security policy. Severity INFO Fabric OS Message Reference 681 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 752
Old FCS position> to . Probable Cause Indicates the fabric configuration server (FCS) list has been modified. One of the members of Reset [] statistics on domains []. Indicates that a user has reset a security statistic on the specified domains. 682 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 753
server for AAA services. Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration was changed intentionally. If the RADIUS configuration was intentionally changed, no action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 754
Info: . Probable Cause Indicates a user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration was intentionally changed. If the RADIUS configuration was intentionally changed, no action is required - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 755
Passwdcfg parameters set to default values. Probable Cause Indicates the passwdCfg parameters are set to default values. Recommended Action Failed login attempt via . Indicates a failed login attempt occurred. Fabric OS Message Reference 685 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 756
, , , , Event: , Status: failed, Info: Account [] locked, failed password attempts exceeded. Probable Cause Indicates the maximum number of failed password entries has been exceeded. The account has been locked as a result. Recommended The - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 757
: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], Status: success, Info: User account [] deleted. Indicates the specified user account was deleted. Fabric OS Message Reference 687 53- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 758
, Info: Backup user account \"\" recovered. Probable Cause Indicates that back user accounts were recovered. : success, Info: Distributed db(s) to domains, dom-id(s). Probable Cause Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 759
, Status: success, Info: Switch is configured to IP filter policy(ies) saved. Indicates the specified IP filter policies have been saved. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 760
IP filter policy failed to activate. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO 690 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 761
violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol Mode>. Indicates there was a change in the FIPS Self Test mode. Fabric OS Message Reference 691 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 762
user has the required permission to execute this command. Action Severity INFO SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled , Info: . 692 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 763
-location>, , The license key is . Probable Cause Indicates that a license key is added or removed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 693 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 764
12 SEC-3051 694 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 765
group> configuration was reset to default. Probable Cause Indicates that the simple network management protocol (SNMP) configuration group was reset to the factory default. Recommended Execute the snmpConfig --show command to display the new group configuration. Action Severity INFO Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 766
12 SNMP-1006 696 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 767
switch firmware FIRMWARE, , , , Firmwarecommit has started. Probable Cause Indicates that the firmwareCommit command has started. Recommended No action is required. Run the firmwareDownloadStatus command for more information. Action Severity INFO Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 768
failed because firmwareDownload is already in progress." "Sanity check failed because FABRIC OS is disabled on Standby CP." "Sanity check failed because HAMD "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 769
CP failed to boot up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." "firmwareDownload has started on 0x76 0x77 0x78 0x79 0x7a 0x7b 0x7c 0x7d Fabric OS Message Reference 699 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 770
"Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry firmwareDownload." 0xa6 "firmwareCommit has started on the blade. This may take up to 10 minutes." 0xa7 700 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 771
is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 772
on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two feature releases (a feature release is indicated by a major number and a minor number, for example, X.Y). The following are major upgrade versions for the Fabric OS: v4 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 773
- The pre-install script failed. This switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware commit operation. Wait until this operation completes (about 10 minutes) before attempting another firmwareDownload. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 774
firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1018 Message Probable Cause AUDIT, , [SULB-1018], ERROR, FIRMWARE, , , , Firmwaredownload timed out in slot . Indicates there may - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 775
firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 776
. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT, , [SULB-1024], WARNING, FIRMWARE, , , , Firmware commit has completed on the blade in slot . Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 777
command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal firmware image on the CP. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 778
to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 779
, Trunk Area () has been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 709 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 780
126 SWCH-1014 710 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 781
Load Sharing option has been enabled. Probable Cause Indicates the DLS option has been enabled for the switch. This will move existing routes to a new redundant path, when this path becomes available. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 711 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 782
>, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of topology changes. Recommended No action is required. Action 712 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 783
Severity INFO 127 UCST-1027 Fabric OS Message Reference 713 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 784
127 UCST-1027 714 Fabric OS Message Reference 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 785
object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the name>\" deleted. Indicates the specified zone object has been deleted. Fabric OS Message Reference 715 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 786
have been removed from the specified zone object set. The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the message. Recommended Verify the event was planned. If the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 787
Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been enabled. Recommended Verify the event was action as defined by your enterprise security policy. Fabric OS Message Reference 717 53-1001338-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 788
action as defined by your enterprise security policy. Severity INFO ZONE-3014 Message Probable Cause AUDIT, , [ZONE-3014], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" added to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 789
FABRIC, , , , Event: , Status: success, Info: AD configurations applied. Probable Cause Indicates the current admin domain (AD) configuration type is "AD member". The string "..." appears at the end of the AD object member list if the list was - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 790
take appropriate action as defined by your enterprise security policy. Severity INFO ZONE-3020 Message AUDIT, , [ZONE-3020], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" removed from - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 791
Message AUDIT, , [ZONE-3022], INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration has been saved to flash. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 792
128 ZONE-3025 Severity INFO 722 Fabric OS Message Reference 53-1001338-01
53-1001338-01
28 July 2009
®
Fabric OS
Message Reference
Supporting Fabric OS v6.3.0