HP StorageWorks 4/64 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 123
ANV System Messages
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
DRAFT: BROCADE CONFIDENTIAL ANV System Messages Chapter 5 ANV-1001 Message , [ANV-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between peer ports. Recommended Verify if you are using compatible SFPs on the peer ports. Verify if the SFPs have deteriorated and if Action the Fibre Channel cable is faulty. Replace the SFPs or the cable if necessary. Severity ERROR ANV-1002 Message , [ANV-1002], ,Ffdc, ERROR, , Port chip faulted due to internal error. Probable Cause Indicates an internal error. All the ports on the blade or switch will be disrupted. Recommended Action For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform the fastBoot command on the switch to recover the system. Severity ERROR ANV-1003 Message , [ANV-1003], ,, CRITICAL, , ,: HW ASIC Chip error. Type = 0x, Error = .. Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Restart the system at the next maintenance window. If the problem persists, replace the blade. Action Severity CRITICAL Fabric OS Message Reference 53 53-1001338-01