HP StorageWorks 8/40 Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01 - Page 122
chassisBeacon, Synopsis, Description, portLoopbackTest, Operands, Examples, See Also, portBeacon
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
2 chassisBeacon chassisBeacon Synopsis Sets chassis beaconing mode. chassisbeacon [mode] Description Use this command to enable or disable beaconing on a chassis. Chassis beaconing can be used to locate a failing port. When beaconing mode is turned on, the port LEDs flash green at various rates across the chassis. The beaconing continues until you turn it off. Beaconing mode takes over the port LEDs. The normal flashing LED pattern associated with an active, faulty, or disabled port is suppressed, and only the beaconing pattern is shown. Other commands are still executable and functional. However, if diagnostic frame-based tests such as portLoopbackTest are executed, the diagnostic LED pattern is interleaved with the beaconing pattern. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operand: mode Specify 1 to enable chassis beaconing mode or 0 to disable beaconing mode. This operand is optional. If no operand is specified, the current value is displayed. Examples To turn chassis beaconing mode on: switch:admin> chassisbeacon 1 Chassis beacon success 1 To turn beaconing mode off: switch:admin> chassisbeacon 0 Chassis beacon success 0 See Also portBeacon, switchShow, switchBeacon 92 Fabric OS Command Reference 53-1001337-01