HP StorageWorks 8/40 Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01 - Page 581
Notes, Operands, class, switchShow, Examples, for a listing of valid ports.
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 581 highlights
perfMonitorShow 2 Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: --class monitor_class slotnumber portnumber interval Specifies the monitor class as one of the following: EE (end-to-end), FLT (filter-based), or ISL (interswitch link). These values are case-sensitive. For bladed systems only, specifies the slot number of the port on which to display the monitor, followed by a slash (/). Specifies the number of the port on which to display the monitor, relative to its slot for bladed systems. Use switchShow for a listing of valid ports. The interval value must be greater than or equal to 5, and it must be a multiple of 5. In the case of end-to-end monitor, Tx and Rx counts are displayed in the unit of byte when this operand is specified. This operand is optional; if the operand is not specified, this command displays cumulative counts. Examples To display filter monitors on port 8: switch:admin> perfmonitorshow --class FLT 8 There are 2 filter-based monitors defined on port 8. KEY ALIAS OWNER_APP FRAME_COUNT OWNER_IP_ADDR 0 IPFrame TELNET 0x0000000000000000 N/A 1 SCSIRead TELNET 0x0000000000000000 N/A To display EE monitors on port 8 switch:admin> perfmonitorshow --class EE 2/8 There are 8 end-to-end monitor(s) defined on port 8. KEY SID DID OWNER_APP TX_COUNT RX_COUNT OWNER_IP_ADDR 0 0xfffff1 0x000001 TELNET 0x0000000000000000 0x0000000000000000 N/A 1 0xfffff2 0x000002 TELNET 0x0000000000000000 0x0000000000000000 N/A 2 0xfffff3 0x000003 TELNET 0x0000000000000000 0x0000000000000000 N/A 3 0xfffff4 0x000004 TELNET 0x0000000000000000 0x0000000000000000 N/A 4 0xfffff5 0x000005 TELNET 0x0000000000000000 0x0000000000000000 N/A 5 0xfffff6 0x000006 TELNET 0x0000000000000000 0x0000000000000000 N/A 6 0xfffff7 0x000007 TELNET 0x0000000000000000 0x0000000000000000 N/A 7 0xfffff8 0x000008 TELNET 0x0000000000000000 0x0000000000000000 N/A 0 0x000000 0x1182ef TELNET 0x0000000000000000 0x0000000000000000 N/A Fabric OS Command Reference 551 53-1001337-01