BL-1027, Recommended, Action, supportSave, diagPost, Severity, Message, Probable Cause
View all HP StorageWorks 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
5 BL-1027 Recommended Collect supportSave information, then reboot switch and run the diagPost command to ensure Action Power-On Self-Test (POST) is enabled. If problem persists, replace switch. Severity CRITICAL BL-1027 Message , [BL-1027], ,, CRITICAL, , Blade in slot faulted, boot failed; status 0x 0x 0x. Probable Cause Indicates that the blade failed to boot properly. Recommended Action Reboot or power cycle the blade. If the message persists, replace the blade. Severity CRITICAL BL-1028 Message , [BL-1028], ,, CRITICAL, , Switch faulted; internal processor was reset before switch init completed. Probable Cause Indicates that the switch's internal processor was reset before the initialization completed. Recommended Action Reboot or power cycle the switch. If the message persists, replace the switch. Severity CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the datapath elements were reset. Recommended No action is required. Action Severity INFO 56 Fabric OS Message Reference 53-1000600-02