HP StorageWorks 8/8 Brocade Error Message Reference Guide v6.1.0 (53-1000600-0 - Page 244
FW-1011, FW-1012, FW-1033, FW-1034
View all HP StorageWorks 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 244 highlights
30 FW-1011 Recommended Verify that you have installed the power supply correctly and that it is correctly seated in the Action chassis. If the problem persists, replace the faulty power supply. Severity WARNING FW-1011 Message , [FW-1011], ,, INFO, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the power supply is functioning properly. Recommended Set the high boundary above the normal operation range. Action Severity INFO FW-1012 Message , [FW-1012], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1033 Message , [FW-1033], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has changed. Frequent fluctuations in SFP temperature might indicate a deteriorating SFP. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1034 Message , [FW-1034], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . 192 Fabric OS Message Reference 53-1000600-02