HP StorageWorks XP12000 HP StorageWorks XP Disk Array Configuration Guide: IBM - Page 33

B Disk array supported emulations, Supported emulations, Emulation specifications

Page 33 highlights

B Disk array supported emulations This appendix provides information about supported emulations and device type specifications. Some parameters may not be relevant to your array. Consult your HP representative for information about supported configurations for your system. Supported emulations HP recommends using OPEN-V as the emulation for better performance and features that may not be supported with the legacy emulations (OPEN-[389LE]). Table 8 Supported emulations XP model Emulation Fixed Size LUSE CVS OPEN-3 Yes Yes Yes XP10000 OPEN-8 Yes Yes Yes XP12000 OPEN-9 Yes Yes Yes XP20000 OPEN-E Yes Yes Yes XP24000 OPEN-K SVS 200 OPEN-L Yes Yes OPEN-M OPEN-V Yes LUSE & CVS Yes Yes Yes Yes Yes NOTE: For the SVS 200, and the XP24000/XP20000/XP12000/XP10000 when connected to external storage devices, HP recommends using OPEN-V as the emulation the array makes visible to the host. This allows external storage LDEVs to be configured without losing data. Using any other emulation may cause data loss in the external storage LUNs. Emulation specifications Table 9 Emulation specifications Emulation (Note 1) OPEN-3 Category (Note 2) SCSI disk Product name (Note 3) OPEN-3 Blocks (512 bytes) 4806720 Sector size (bytes) 512 # of cylinders Heads Sectors per track 3338 15 96 Capacity MB* (Note 4) 2347 XP Disk Array Configuration Guide for IBM AIX 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

B Disk array supported emulations
This appendix provides information about supported emulations and device type specifications. Some
parameters may not be relevant to your array. Consult your HP representative for information about
supported configurations for your system.
Supported emulations
HP recommends using OPEN-V as the emulation for better performance and features that may not be
supported with the legacy emulations (OPEN-[389LE]).
Table 8 Supported emulations
LUSE & CVS
CVS
LUSE
Fixed Size
Emulation
XP model
Yes
Yes
Yes
Yes
OPEN-3
Yes
Yes
Yes
Yes
OPEN-8
XP10000
Yes
Yes
Yes
Yes
OPEN-9
XP12000
Yes
Yes
Yes
Yes
OPEN-E
XP20000
OPEN-K
XP24000
Yes
Yes
OPEN-L
SVS 200
OPEN-M
Yes
Yes
OPEN-V
NOTE:
For the SVS 200, and the XP24000/XP20000/XP12000/XP10000 when connected to external
storage devices, HP recommends using OPEN-V as the emulation the array makes visible to the host.
This allows external storage LDEVs to be configured without losing data. Using any other emulation
may cause data loss in the external storage LUNs.
Emulation specifications
Table 9 Emulation specifications
Capacity
MB*
(Note 4)
Sectors
per
track
Heads
# of
cylinders
Sector
size
(bytes)
Blocks
(512 bytes)
Product name
(Note 3)
Category
(Note 2)
Emulation
(Note 1)
2347
96
15
3338
512
4806720
OPEN-3
SCSI disk
OPEN-3
XP Disk Array Configuration Guide for IBM AIX