HP Surestore 160fx Optical Drive and Library SCSI-2 Command Reference - Page 223
Send Diagnostic Command Data, Test Number, Break, Loop Count, Identifier, Parameters, Table 3-32
View all HP Surestore 160fx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 223 highlights
Table 3-32 Jukebox SCSI-2 Command Set Send Diagnostic Command (1DH) Send Diagnostic Command Data Send Diagnostic Command Parameter List Byte 7 6 5 4 3 2 1 0 0 Test Number 1 Break Loop Count Identifier 2 Parameters 3 Parameters 4 Parameters 5 Parameters 6 Parameters 7 Parameters 8 Parameters 9 Parameters Test Number Break Loop Count Identifier Parameters Diagnostic test number. See Table B-12 on page B-40 or Table B-13 on page B-44 for a list of the jukebox diagnostic tests. Indicates how to terminate the loop count if an error occurs. 0 - Break on first error 1 - Do not break on error The number of times the test will be repeated before the test is terminated and status is returned. 1H - Run 1 time 2H - Run 10 times 3H - Run 100 times 4H - Run 1000 times Parameters associated with the specified tests. 3-36 Chapter 3