HP Surestore 160fx Optical Drive and Library SCSI-2 Command Reference - Page 250
Move History Log Data Format, Table 3-66, Description
View all HP Surestore 160fx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 250 highlights
Jukebox SCSI-2 Commands NOTE Table 3-66 Table 3-67 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Move History Log Data Format This log is ONLY supported on the 40fx, 80ex, 125ex and 220mx models. This table can bee accessed via the Log Sense Command (4DH), Table 345 on page 3-47 with page code 3AH. Move History Log Data Format Byte Description 0 1 2-3 4-83 Page Code 3AH Reserved = 0 Number of bytes to follow 6 History Log entries, 8 bytes each (see Move History Log Entry Format Byte Description 0 Least recent Micro-Move ID (Table D-2 on page D-17) 1 Next recent Micro-Move ID (Table D-2 on page D-17) 2 Next recent Micro-Move ID (Table D-2 on page D-17) 3 Next recent Micro-Move ID (Table D-2 on page D-17) 4 Next recent Micro-Move ID (Table D-2 on page D-17) 5 Failed Micro-Move ID (Table D-2 on page D-17) 16 Micro-Move Error Code (Table B-10 on page B-32) 7 Reserved (0) Micro-Move IDs are the last moves prior to failure, associated with Bytes 5 and 6. Chapter 3 3-63