Table B-6, Request Sense - Additional Sense Data, For models 40fx, 80ex, 125ex and 220mx ONLY
View all HP Surestore 160fx manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 301 highlights
Autochanger Error Codes Additional Sense Data Format for Error Recovery Table B-6 Request Sense - Additional Sense Data (For models 40fx, 80ex, 125ex and 220mx ONLY) Byte 7 6 5 4 3 2 1 0 18 Move Error (Table B-9 on page B-29) 19 Hardware Error Code (Table B-8 on page B-22) 20 First FRU (Table A-2 on page A-4) 21 Second FRU (Table A-2 on page A-4) 22 Third FRU (Table A-2 on page A-4) 23 MvCap Last Rsvd PosLost CartIn Reserved (0) (0) 24-25 Reserved (0) 26 DInRty DEjRty PkrRec CarAssy Reserved (0) BFHm FHR 27 Retry Count 28-29 Reserved (0) 30 DInRty DEjRty PkrRec CarAssy Reserved (0) BFHm FHR 31 Recovery Count 32-34 Reserved (0) 35 Valid ErrEn CartIn CartEl UnexpMt UnexpFl CartInv ElRty 36-37 Source Element Number 38 Valid ErrEn CartIn CartEl UnexpMt UnexpFl CartInv ElRty 39-40 Destination Element Number 41 Valid ErrEn CartIn CartEl UnexpMt UnexpFl CartInv ElRty 42-43 Secondary Source Element Number 44 Valid ErrEn CartIn CartEl UnexpMt UnexpFl CartInv ElRty 45-46 Second Destination Element Number B-14 Appendix B