HP TC1000 Maintenance and Service Guide, Compaq Tablet PC TC1000 - Page 117
Removing the System Board Screws, Next to the pen holder spring clip
UPC - 613326724071
View all HP TC1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Removal and Replacement Procedures 13. Release the ZIF connector 1 to which the LED board cable is attached and disconnect the LED board cable 2 from the system board (Figure 5-24). 14. Remove the four PM2.0 × 5.0 screws that secure the system board to the base enclosure. The screws are located in the following locations: ❏ Next to the pen holder spring clip 3 ❏ Directly behind the USB connectors 4 ❏ Directly behind the external monitor connector 5 ❏ Left side of the heat sink grille 6 Figure 5-24. Removing the System Board Screws Maintenance and Service Guide 5-29
Removal and Replacement Procedures
Maintenance and Service Guide
5–29
13.
Release the ZIF connector
1
to which the LED board cable is
attached and disconnect the LED board cable
2
from the
system board (Figure 5-24).
14. Remove the four PM2.0 × 5.0 screws that secure the system
board to the base enclosure. The screws are located in the
following locations:
❏
Next to the pen holder spring clip
3
❏
Directly behind the USB connectors
4
❏
Directly behind the external monitor connector
5
❏
Left side of the heat sink grille
6
Figure 5-24. Removing the System Board Screws