DIMM Card Slot Numbers and Loading Sequence

Page 142 highlights

Field Replaceable Units FRU Removal and Replacement 4. For ease in installation of additional memory the hard disk drive fan may need to be removed. See the section "Removing the Fan from the Hard Disk Drive Area" on page 110 in this chapter. 5. Load the DIMM cards in the slots using the loading sequence provided in Figure 4-56. Figure 4-56. DIMM Card Slot Numbers and Loading Sequence Disk/Memory Fan NOTE When installing DIMMs, you need to orient the notches on the bottom edge of the DIMM card so that they are aligned with the keys on the DIMM connector. See Figure 4-57. The keyed DIMM connectors prevent you from installing the DIMM cards backwards. 6. Press downward on the ejector tabs located on both sides of the DIMM connector. See Figure 4-57. This opens the connector for DIMM card insertion. 142 Chapter 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239

142
Chapter 4
Field Replaceable Units
FRU Removal and Replacement
4. For ease in installation of additional memory the hard disk drive fan may need to be
removed. See the section “Removing the Fan from the Hard Disk Drive Area” on page
110 in this chapter.
5.
Load the DIMM cards in the slots using the loading sequence provided in Figure 4-56.
Figure 4-56. DIMM Card Slot Numbers and Loading Sequence
NOTE
When installing DIMMs, you need to orient the notches on the bottom edge of
the DIMM card so that they are aligned with the keys on the DIMM
connector. See Figure 4-57. The keyed DIMM connectors prevent you from
installing the DIMM cards backwards.
6. Press downward on the ejector tabs located on both sides of the DIMM connector. See
Figure 4-57. This opens the connector for DIMM card insertion.
Disk/Memory
Fan