HP XP20000/XP24000 HP StorageWorks XP Disk Array Mainframe Host Attachment and - Page 21

Cascaded FICON topology, Channel link, which connects to a Fibre Channel switch

Page 21 highlights

Sharing a control unit through a Fibre Channel switch allows communication between a number of channels and the control unit to occur either: • Over one switch-to-CU link, such as when a control unit has only one link to the Fibre Channel switch, or • Over multiple-link interfaces, such as when a control unit has more than one link to the Fibre Channel switch. In a FICON switched point-to-point topology, one Fibre Channel link is attached to the FICON channel. From the switch, the FICON channel communicates with a number of FICON CUs on different switch ports. At the control unit, the control unit and device-addressing capability is the same as the point-to-point topology. However, communication and addressing capabilities are increased for the channel when it is connected to a Fibre Channel switch, and can use the domain and port address portion of the 24-bit N_Port address to access multiple control units. The communication path between a channel and a control unit consists of the physical channel path and the logical path. In a FICON switched point-to-point topology with a single switch, the physical paths are the Fibre Channel links (interconnection of two Fibre Channel links connected by a Fibre Channel switch) that provide the physical transmission path between a channel and a control unit. Figure 9 Example of a switched point-to-point topology . Cascaded FICON topology A FICON channel in FICON native (FC) mode connects one or more processor images to a Fibre Channel link, which connects to a Fibre Channel switch, and then dynamically through one or more FC switch ports (internally within the switch) to a second FC switch in a remote site via FC link(s). From the second FC switch port, a number of Fibre Channel links connect to FICON CU ports, which interconnect with one or more control units and/or images (logical control units). This forms a cascaded FICON topology (see the following figure). The cascaded FICON directors topology is only supported by IBM zSeries processors. XP Disk Array Mainframe Host Attachment and Operations Guide 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Sharing a control unit through a Fibre Channel switch allows communication between a number of
channels and the control unit to occur either:
Over one switch-to-CU link, such as when a control unit has only one link to the Fibre Channel
switch, or
Over multiple-link interfaces, such as when a control unit has more than one link to the Fibre
Channel switch.
In a FICON switched point-to-point topology, one Fibre Channel link is attached to the FICON channel.
From the switch, the FICON channel communicates with a number of FICON CUs on different switch
ports. At the control unit, the control unit and device-addressing capability is the same as the
point-to-point topology. However, communication and addressing capabilities are increased for the
channel when it is connected to a Fibre Channel switch, and can use the domain and port address
portion of the 24-bit N_Port address to access multiple control units.
The communication path between a channel and a control unit consists of the physical channel path
and the logical path. In a FICON switched point-to-point topology with a single switch, the physical
paths are the Fibre Channel links (interconnection of two Fibre Channel links connected by a Fibre
Channel switch) that provide the physical transmission path between a channel and a control unit.
Figure 9 Example of a switched point-to-point topology
.
Cascaded FICON topology
A FICON channel in FICON native (FC) mode connects one or more processor images to a Fibre
Channel link, which connects to a Fibre Channel switch, and then dynamically through one or more
FC switch ports (internally within the switch) to a second FC switch in a remote site via FC link(s).
From the second FC switch port, a number of Fibre Channel links connect to FICON CU ports, which
interconnect with one or more control units and/or images (logical control units). This forms a cascaded
FICON topology (see the following figure). The cascaded FICON directors topology is only supported
by IBM zSeries processors.
XP Disk Array Mainframe Host Attachment and Operations Guide
21