Hardware definition using HCD (MVS/ESA), require FEATURE=SHARED.

Page 32 highlights

• To protect data integrity due to multiple operating systems sharing these volumes, these devices require FEATURE=SHARED. NOTE: If you maintain separate IOCP definitions files and create your SCDS or IOCDS manually by running the IZP IOCP or ICP IOCP program, you must define each CU image on a storage system using one CNTLUNIT statement in IOCP. While it is possible to define a CU image on a storage system using multiple CNTLUNIT statements in IOCP, the resulting input deck cannot be migrated to HCD due to an IBM restriction allowing only one CNTLUNIT definition. CHPID PATH=(60,61,62,63,64,65,66,67),TYPE=CNC CNTLUNIT CUNUMBR=8000,PATH=(60,61,62,63,64,65,66,67), * UNITADD=((00,256)),CUADD=0,UNIT=2105 CNTLUNIT CUNUMBR=8100,PATH=(60,61,62,63,64,65,66,67), * UNITADD=((00,256)),CUADD=1,UNIT=2105 CNTLUNIT CUNUMBR=8200,PATH=(60,61,62,63,64,65,66,67), * UNITADD=((00,256)),CUADD=2,UNIT=2105 CNTLUNIT CUNUMBR=8300,PATH=(60,61,62,63,64,65,66,67), * UNITADD=((00,256)),CUADD=3,UNIT=2105 IODEVICE ADDRESS=(8000,128),CUNUMBR=(8000),STADET=Y,UNIT=3390B,FEATURE=SHARED IODEVICE ADDRESS=(8080,128),CUNUMBR=(8000),STADET=Y,UNIT=3390A,FEATURE=SHARED IODEVICE ADDRESS=(8100,128),CUNUMBR=(8100),STADET=Y,UNIT=3390B,FEATURE=SHARED IODEVICE ADDRESS=(8180,128),CUNUMBR=(8100),STADET=Y,UNIT=3390A,FEATURE=SHARED IODEVICE ADDRESS=(8200,064),CUNUMBR=(8200),STADET=Y,UNIT=3390B,FEATURE=SHARED IODEVICE ADDRESS=(8240,192),CUNUMBR=(8200),STADET=Y,UNIT=3390A,FEATURE=SHARED IODEVICE ADDRESS=(8300,128),CUNUMBR=(8300),STADET=Y,UNIT=3390,FEATURE=SHARED IODEVICE ADDRESS=(8380,064),CUNUMBR=(8300),STADET=Y,UNIT=3390B,FEATURE=SHARED IODEVICE ADDRESS=(83C0,064),CUNUMBR=(8300),STADET=Y,UNIT=3390A,FEATURE=SHARED Hardware definition using HCD (MVS/ESA) The HCD utility can be used to define the storage system in an MVS/ESA environment. The HCD procedures for 3990 and 2105 controller emulation types are described as follows. FICON/zHPF interface requires 2105-F20 emulation or 2107. 3990 Controller Emulation: To define a storage system with 64 or fewer LVIs, use the same procedure as for an IBM 3990-6/6E storage system (see Table 10). The hardware definition for a storage system with more than 64 LVIs (see Table 11) is different than that for an IBM 3990 storage system. Table 10 HCD definition for 64 LVIs Control Frame: Parameter Value Control unit number Specify the control unit number. Control unit type 3990-6 or 3990-6E (using 3990-6 emulation) Channel path IDs Specify ExSA or FICON Unit address 00 (ExSA or FICON) Number of units 64 Array Frame: Device number Specify the first device number. 32 Mainframe operations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

To protect data integrity due to multiple operating systems sharing these volumes, these devices
require FEATURE=SHARED.
NOTE:
If you maintain separate IOCP definitions files and create your SCDS or IOCDS manually by running
the IZP IOCP or ICP IOCP program, you must define each CU image on a storage system using one
CNTLUNIT statement in IOCP. While it is possible to define a CU image on a storage system using
multiple CNTLUNIT statements in IOCP, the resulting input deck cannot be migrated to HCD due to
an IBM restriction allowing only one CNTLUNIT definition.
CHPID PATH=(60,61,62,63,64,65,66,67),TYPE=CNC
CNTLUNIT CUNUMBR=8000,PATH=(60,61,62,63,64,65,66,67),
*
UNITADD=((00,256)),CUADD=0,UNIT=2105
CNTLUNIT CUNUMBR=8100,PATH=(60,61,62,63,64,65,66,67),
*
UNITADD=((00,256)),CUADD=1,UNIT=2105
CNTLUNIT CUNUMBR=8200,PATH=(60,61,62,63,64,65,66,67),
*
UNITADD=((00,256)),CUADD=2,UNIT=2105
CNTLUNIT CUNUMBR=8300,PATH=(60,61,62,63,64,65,66,67),
*
UNITADD=((00,256)),CUADD=3,UNIT=2105
IODEVICE ADDRESS=(8000,128),CUNUMBR=(8000),STADET=Y,UNIT=3390B,FEATURE=SHARED
IODEVICE ADDRESS=(8080,128),CUNUMBR=(8000),STADET=Y,UNIT=3390A,FEATURE=SHARED
IODEVICE ADDRESS=(8100,128),CUNUMBR=(8100),STADET=Y,UNIT=3390B,FEATURE=SHARED
IODEVICE ADDRESS=(8180,128),CUNUMBR=(8100),STADET=Y,UNIT=3390A,FEATURE=SHARED
IODEVICE ADDRESS=(8200,064),CUNUMBR=(8200),STADET=Y,UNIT=3390B,FEATURE=SHARED
IODEVICE ADDRESS=(8240,192),CUNUMBR=(8200),STADET=Y,UNIT=3390A,FEATURE=SHARED
IODEVICE ADDRESS=(8300,128),CUNUMBR=(8300),STADET=Y,UNIT=3390,FEATURE=SHARED
IODEVICE ADDRESS=(8380,064),CUNUMBR=(8300),STADET=Y,UNIT=3390B,FEATURE=SHARED
IODEVICE ADDRESS=(83C0,064),CUNUMBR=(8300),STADET=Y,UNIT=3390A,FEATURE=SHARED
Hardware definition using HCD (MVS/ESA)
The HCD utility can be used to define the storage system in an MVS/ESA environment. The HCD
procedures for 3990 and 2105 controller emulation types are described as follows. FICON/zHPF
interface requires 2105-F20 emulation or 2107.
3990 Controller Emulation:
To define a storage system with 64 or fewer LVIs, use the same procedure
as for an IBM 3990-6/6E storage system (see
Table 10
). The hardware definition for a storage system
with more than 64 LVIs (see
Table 11
) is different than that for an IBM 3990 storage system.
Table 10 HCD definition for 64 LVIs
Value
Parameter
Control Frame:
Specify the control unit number.
Control unit number
3990-6 or 3990-6E (using 3990-6 emulation)
Control unit type
Specify ExSA or FICON
Channel path IDs
00 (ExSA or FICON)
Unit address
64
Number of units
Array Frame:
Specify the first device number.
Device number
Mainframe operations
32