HP XP20000/XP24000 HP StorageWorks XP Disk Array Mainframe Host Attachment and - Page 36

Control unit type: 2105

Page 36 highlights

5. On the Add Control Unit panel, input the following new information, or edit the information if pre-loaded from an "Add like" operation, and then press Enter: • Control unit number • Control unit type: 2105 • Switch information only if a switch exists. Otherwise leave switch and ports blank. Add Control Unit | | | | | Specify or revise the following values. | | | | Control unit number . . . . 8000 + | | | | Control unit type . . . . . 2105_________ + | | | | Serial number | | Description new 2105 type for 80xx devices__ | | | | Connected to switches | | Ports | | | | If connected to a switch, select whether to have CHPIDs/link | | addresses, and unit address range proposed. | | | | Auto-assign 2 1. Yes | | 2. No | | | | F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap | | F12=Cancel | 6. On the Select Processor / Control Unit panel, input an S next to the PROC. ID, and then press Enter. Goto Filter Backup Query Help Select Processor / Control Unit | Row 1 of 1 More: >| | Command Scroll ===> PAGE | | | | Select processors to change CU/processor parameters, then press Enter. | | | | Control unit number . . : 8000 Control unit type . . . : 2105 | | | | Log. Addr. -------Channel Path ID . Link Address + ------- | | / Proc. ID Att. (CUADD) + 1---- 2---- 3---- 4---- 5---- 6---- 7---- 8---- | | S PROD __ Bottom of data | | | | | | | | | | | | | | | | | F1=Help F2=Split F3=Exit F4=Prompt F5=Reset | | F6=Previous F7=Backward F8=Forward F9=Swap F12=Cancel | | F6=Previous F7=Backward F8=Forward F9=Swap F12=Cancel | 36 Mainframe operations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

5.
On the
Add Control Unit
panel, input the following new information, or edit the information if
pre-loaded from an
Add like
operation, and then press
Enter
:
Control unit number
Control unit type: 2105
Switch information only if a switch exists. Otherwise leave switch and ports blank.
.-------------------------- Add Control Unit ---------------------------.
|
|
|
|
| Specify or revise the following values.
|
|
|
| Control unit number
....
8000
+
|
|
|
| Control unit type
.....
2105
_________
+
|
|
|
| Serial number
.......
__________
|
| Description
........
new 2105 type for 80xx devices__
|
|
|
| Connected to switches
. . . __
__
__
__
__
__
__
__
+
|
| Ports
...........
__
__
__
__
__
__
__
__
+
|
|
|
| If connected to a switch, select whether to have CHPIDs/link
|
| addresses, and unit address range proposed.
|
|
|
| Auto-assign
........
2
1.
Yes
|
|
2.
No
|
|
|
|
F1=Help
F2=Split
F3=Exit
F4=Prompt
F5=Reset
F9=Swap
|
| F12=Cancel
|
'-----------------------------------------------------------------------'
6.
On the
Select Processor / Control Unit
panel, input an
S
next to the PROC. ID, and then press
Enter
.
Goto
Filter
Backup
Query
Help
.---------------------- Select Processor / Control Unit ----------------------.
|
Row 1 of 1 More:
>|
| Command ===> ___________________________________________ Scroll ===> PAGE
|
|
|
| Select processors to change CU/processor parameters, then press
Enter
.
|
|
|
| Control unit number . . : 8000
Control unit type . . . : 2105
|
|
|
|
Log. Addr. -------Channel Path ID . Link Address + -------
|
| / Proc. ID Att. (CUADD) +
1---- 2---- 3---- 4---- 5---- 6---- 7---- 8----
|
|
S
PROD
__
_____ _____ _____ _____ _____ _____ _____ _____
|
| ***************************** Bottom of data ****************************** |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F1=Help
F2=Split
F3=Exit
F4=Prompt
F5=Reset
|
|
F6=Previous
F7=Backward
F8=Forward
F9=Swap
F12=Cancel
|
'-----------------------------------------------------------------------------'
|
F6=Previous
F7=Backward
F8=Forward
F9=Swap
F12=Cancel
|
'-----------------------------------------------------------------------------'
Mainframe operations
36