HP XP20000/XP24000 HP StorageWorks XP Disk Array Mainframe Host Attachment and - Page 58

Native FICON configuration on a zSeries or S/390 host, FICON mixed channel configuration

Page 58 highlights

Figure 21 FICON mixed channel configuration . In the example, one FICON bridge was removed from the configuration. The FICON channel that was connected to that bridge is reconnected to the new FICON director using the storage unit FICON adapter. The channel-path group was changed to include the new FICON path. The channel-path group is now a mixed ESCON and FICON path group. I/O operations continue to the storage unit across this mixed path group. Access to the storage unit devices is not interrupted because all the actions are non-disruptive. NOTE: • This configuration is supported for migration only. • Do not use this configuration for an extended period. • Migrate from a mixed channel-path group configuration to an all FICON channel-path group configuration. Native FICON configuration on a zSeries or S/390 host The following figure shows an S/390 or zSeries host system with two FICON channels connected to two FICON directors through a channel-path group to two FICON adapters. Note that the second bridge has been removed and a FICON director has been added. The channel-path group has only the FICON paths. 58 Linux operations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Figure 21 FICON mixed channel configuration
.
In the example, one FICON bridge was removed from the configuration. The FICON channel that
was connected to that bridge is reconnected to the new FICON director using the storage unit FICON
adapter. The channel-path group was changed to include the new FICON path. The channel-path
group is now a mixed ESCON and FICON path group. I/O operations continue to the storage unit
across this mixed path group. Access to the storage unit devices is not interrupted because all the
actions are non-disruptive.
NOTE:
This configuration is supported for migration only.
Do not use this configuration for an extended period.
Migrate from a mixed channel-path group configuration to an all FICON channel-path group
configuration.
Native FICON configuration on a zSeries or S/390 host
The following figure shows an S/390 or zSeries host system with two FICON channels connected to
two FICON directors through a channel-path group to two FICON adapters. Note that the second
bridge has been removed and a FICON director has been added. The channel-path group has only
the FICON paths.
Linux operations
58