Hitachi NV83A2 Instruction Manual - Page 10

Optional Accessories, Applications, Before Operation, Working Environment, Warning, Air Supply, - framing nailer

Page 10 highlights

English OPTIONAL ACCESSORIES ... sold separately ⅜ Sequential Trip Mechanism Kit (Code No. 876762) (Single Shot Parts) ⅜ Pneumatic Tool Lubricant .8 oz. (25 cc) oil feeder (Code No. 877153) 4 oz. (120 cc) oil feeder (Code No. 874042) 1 quart (1 ltr) can (Code No. 876212) NOTE: Accessories are subject to change without any obligation on the part of HITACHI. APPLICATIONS ⅜ Construction wooden work such as floor and wall framing, roof decking, subflooring. ⅜ Mobile and modular home construction. ⅜ Making wooden boxes, palletes, and drums. ⅜ Packing operations in manufacturing plants, and other types of packing and crating work in general. ⅜ Making wooden boxes, and light pallets. ⅜ Making wooden furniture, wooden sash, and other wooden products. ⅜ Packing operations in manufacturing plants, and other types of packing and crating work in general. ⅜ Construction work in general such as prefabricated houses. NOTE: ⅜ Aluminium nails may bend when used on hard surfaces. Test before use. BEFORE OPERATION Read section titled "SAFETY" (pages 4 - 7). Make sure of the followings before operation. WORKING ENVIRONMENT WARNING ⅷ No flammable gas, liquid or other flammable objects at worksite. ⅷ Clear the area of children or unauthorized personnel. AIR SUPPLY DANGER ⅷ NEVER use oxygen or other bottled gases. Explosion may occur. WARNING ⅷ Never connect Nailer to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm2). ⅷ Never use non relieving coupler on Nailer. 1. Power source ⅜ Use only clean, dry, regulated compressed air as a power source for this Nailer. ⅜ Air compressors used to supply compressed air to this Nailer must comply with the requirements of the latest version of ANSI Standard B 19.3 "Safety Standard For Compressors For Process Industries." ⅜ Moisture or oil in the air compressor may accelerate wear and corrosion in the Nailer. Drain daily. 2. Filter-Regulator-Lubricator ⅜ Use a regulator with a pressure range of 0 - 120 psi (0 - 8.3 bar 0 - 8.5 kgf/cm2). ⅜ Filter-regulator-lubricator units supply an optimum condition for the Nailer and extend the Nailer life. These units should always be used. Filter The filter removes moisture and dirt mixed in compressed air. Drain daily unless fitted with an automatic drain. Keep the filter clean by regular maintenance. Regulator ..... The regulator controls the operating pressure for safe operation of the Nailer. Inspect the regulator before operation to be sure it operates properly. Lubricator .... The lubricator supplies an oil mist to the Nailer. Inspect the lubricator before operation to be sure the supply of lubricant is adequate. Use Hitachi pneumatic tool lubricant. Nailer Side Regulator Compressor Side Lubricator Filter - 10 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

— 10 —
English
OPTIONAL ACCESSORIES
... sold separately
²
Sequential Trip Mechanism Kit
(Code No. 876762)
(Single Shot Parts)
²
Pneumatic Tool Lubricant
.8 oz. (25 cc) oil feeder
(Code No. 877153)
4 oz. (120 cc) oil feeder
(Code No. 874042)
1 quart (1 ltr) can
(Code No. 876212)
NOTE:
Accessories are subject to change without any
obligation on the part of HITACHI.
APPLICATIONS
<NV83A2, NV65AC>
²
Construction wooden work such as floor and wall
framing, roof decking, subflooring.
²
Mobile and modular home construction.
²
Making wooden boxes, palletes, and drums.
²
Packing operations in manufacturing plants, and other
types of packing and crating work in general.
<NV50A1>
²
Making wooden boxes, and light pallets.
²
Making wooden furniture, wooden sash, and other
wooden products.
²
Packing operations in manufacturing plants, and other
types of packing and crating work in general.
²
Construction work in general such as prefabricated
houses.
NOTE:
²
Aluminium nails may bend when used on hard
surfaces.
Test before use.
BEFORE OPERATION
Read section titled “SAFETY” (pages 4 – 7).
Make sure of the followings before operation.
WORKING ENVIRONMENT
WARNING
±
No flammable gas, liquid or other flammable
objects at worksite.
±
Clear the area of children or unauthorized
personnel.
AIR SUPPLY
DANGER
±
NEVER use oxygen or
other bottled gases.
Explosion may occur.
WARNING
±
Never connect Nailer to pressure which
potentially exceeds 200 psi (13.7 bar
14 kgf/cm
2
).
±
Never use non relieving coupler on Nailer.
1.
Power source
²
Use only clean, dry, regulated compressed air as a
power source for this Nailer.
²
Air compressors used to supply compressed air to this
Nailer must comply with the requirements of the latest
version of ANSI Standard B 19.3 “Safety Standard For
Compressors For Process Industries.”
²
Moisture or oil in the air compressor may accelerate
wear and corrosion in the Nailer.
Drain daily.
2. Filter-Regulator-Lubricator
²
Use a regulator with a pressure range of 0 – 120 psi
(0 – 8.3 bar
0 – 8.5 kgf/cm
2
).
²
Filter-regulator-lubricator units supply an optimum
condition for the Nailer and extend the Nailer life.
These units should always be used.
Filter
.............
The filter removes moisture and dirt
mixed in compressed air.
Drain daily unless fitted with an
automatic drain.
Keep the filter clean by regular
maintenance.
Regulator
.....
The regulator controls the operating
pressure for safe operation of the Nailer.
Inspect the regulator before operation to
be sure it operates properly.
Lubricator
....
The lubricator supplies an oil mist to the
Nailer.
Inspect the lubricator before operation to
be sure the supply of lubricant is
adequate.
Use Hitachi pneumatic tool lubricant.
Compressor Side
Nailer Side
Filter
Lubricator
Regulator