Honeywell CT3451 Owner's Manual - Page 4

Fig. 8. Typical cool system hookup with 3-wire - installation

Page 4 highlights

CT3451 PROGRAMMABLE THERMOSTAT THERMOSTAT G Rc R 3 1 L1 (HOT) L2 W Y HEAT RELAY FAN RELAY COMPRESSOR CONTACTOR B O 2 COOL DAMPER 2 HEAT DAMPER TRANSFORMER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT PUMP SYSTEMS. 3 JUMPER R TO Rc. M20510 Fig. 6. Typical heat-cool system hookup with single transformer. THERMOSTAT G Rc R W B Y O HEATING 1 RELAY AND FAN COIL 24V 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M20536 Fig. 7. Typical heat system hookup with 2-wire, heatonly system. THERMOSTAT G Rc R W B Y O FAN COIL 1 L1 (HOT) L2 COOLIING CONTRACTOR COIL 24V 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M20537 Fig. 8. Typical cool system hookup with 3-wire, cool-only system. THERMOSTAT G Rc R 2 W B Y O 1 L1 (HOT) L2 FAN RELAY 3 COOL DAMPER 3 HEAT DAMPER COMPRESSOR CONTACTOR HEAT RELAY 1 L1 (HOT) L2 COOLING HEATING TRANSFORMER TRANSFORMER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSFORMER SYSTEM. 3 CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT PUMP SYSTEMS. M20511 Fig. 9. Typical heat-cool system hookup with two transformers. 69-1620-1 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

CT3451 PROGRAMMABLE THERMOSTAT
69-1620—1
4
Fig. 6. Typical heat-cool system hookup with single
transformer.
Fig. 7. Typical heat system hookup with 2-wire, heat-
only system.
Fig. 8. Typical cool system hookup with 3-wire,
cool-only system.
Fig. 9. Typical heat-cool system hookup with two
transformers.
L1
(HOT)
L2
M20510
FAN
RELAY
THERMOSTAT
COMPRESSOR
CONTACTOR
TRANSFORMER
COOL
DAMPER
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT
PUMP SYSTEMS.
JUMPER R TO Rc.
2
2
2
1
Y
G
Rc
W
3
R
B
O
HEAT
RELAY
HEAT
DAMPER
3
1
1
HEATING
RELAY AND
FAN COIL
24V
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
M20536
THERMOSTAT
Y
G
Rc
W
R
B
O
L1
(HOT)
L2
1
FAN
COIL
COOLIING
CONTRACTOR
COIL
24V
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
M20537
THERMOSTAT
Y
G
Rc
W
R
B
O
1
Y
G
Rc
W
2
R
B
O
M20511
L1
(HOT)
L2
FAN
RELAY
HEAT
RELAY
L1
(HOT)
L2
COMPRESSOR
CONTACTOR
HEATING
TRANSFORMER
COOLING
TRANSFORMER
HEAT
DAMPER
COOL
DAMPER
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSFORMER
SYSTEM.
CAN BE USED FOR CHANGEOVER VALVE ON SINGLE-STAGE HEAT
PUMP SYSTEMS.
2
3
3
1
1
3
THERMOSTAT