Honeywell CT3451 Owner's Manual - Page 6

Customize Your Thermostat - instructions

Page 6 highlights

CT3451 PROGRAMMABLE THERMOSTAT AA BATTERIES (3) PM TUE AuFtoANOn Hold Select CoolSOYfSf THEeMat - Release the keys to display the three-digit software revision code. (Information displayed varies by model). M12583 - Press the ▲ key. FC (factory configuration) displays. (A typical example is shown, but information displayed varies by model. This information is for factory use only.) M20514 Fig. 13. Installing batteries. ❑ Restore power to the heating/cooling system. 8 CUSTOMIZE YOUR THERMOSTAT Your Honeywell thermostat comes preset to the most commonly used settings: - Temperature (°F). - Gas or oil forced air furnace. - Aggressive algorithm control. M12584A ❑ Setting °C or °F. - Press the ▲ key again to display the current setting. - Press the ▼ key to change the °C or °F indication. ❑ Setting Heat Cycle Rate (see Table 2 for the cycle rate options and equipment). - Press the ▲ key to display the current heat cycle rate setting of 1, 3, 4, 5, 9, or 12 cph. You can change these settings using the instructions that follow. To exit at any time, press the ▲ key until End displays. Setting °F/°C Indication, Heat Cycle Rate, Heating/Cooling Temperature Control The following instructions provide information to change the heating cycle rate to match the heating equipment and to choose either the Fahrenheit (°F) or Celsius (°C) display. NOTE: All four steps must be completed to save changes to the °F/°C indication and the heat cycle rate. ❑ Enter Installer Setup. - Use ▼ or ▲ keys to set the temperature setpoint to 52°F (11°C). M12589A - If the desired cycle rate is displayed, press the ▲ key to display heating and cooling algorithm default. M12588A - To change the heat cycle rate, press the ▼ key until your choice of 1, 3, 4, 5, 6, 9, or 12 is displayed. - Press the ▲ key to display the heating and cooling temperature control algorithm configuration default. SET HT. M12582A - Press ▼ and ▲ keys simultaneously for more than two seconds to enter Installer Setup. M14691 - Press the ▼ key to change the heating and cooling control algorithm to C1 or C3. C1 = Standard control algorithm. C3 = Aggressive control algorithm (Default. Can cause overshooting.) 69-1620-1 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

CT3451 PROGRAMMABLE THERMOSTAT
69-1620—1
6
Fig. 13. Installing batteries.
Restore power to the heating/cooling system.
8 CUSTOMIZE YOUR THERMOSTAT
Your Honeywell thermostat comes preset to the most
commonly used settings:
— Temperature (°F).
— Gas or oil forced air furnace.
— Aggressive algorithm control.
You can change these settings using the instructions that
follow. To exit at any time, press the
key until End
displays.
Setting °F/°C Indication, Heat Cycle Rate,
Heating/Cooling Temperature Control
The following instructions provide information to change
the heating cycle rate to match the heating equipment
and to choose either the Fahrenheit (°F) or Celsius (°C)
display.
NOTE:
All four steps must be completed to save
changes to the °F/°C indication and the heat
cycle rate.
Enter Installer Setup.
Use
or
keys to set the temperature setpoint
to 52°F (11°C).
Press
and
keys simultaneously for more
than two seconds to enter Installer Setup.
Release the keys to display the three-digit soft-
ware revision code. (Information displayed varies
by model).
Press the
key. FC (factory configuration) dis-
plays. (A typical example is shown, but informa-
tion displayed varies by model. This information
is for factory use only.)
Setting °C or °F.
Press the
key again to display the current
setting.
Press the
key to change the °C or °F indication.
Setting Heat Cycle Rate (see Table 2 for the cycle rate
options and equipment).
Press the
key to display the current heat cycle
rate setting of 1, 3, 4, 5, 9, or 12 cph.
If the desired cycle rate is displayed, press the
key to display heating and cooling algorithm
default.
To change the heat cycle rate, press the
key
until your choice of 1, 3, 4, 5, 6, 9, or 12 is dis-
played.
Press the
key to display the heating and
cooling temperature control algorithm configura-
tion default.
Press the
key to change the heating and cool-
ing control algorithm to C1 or C3.
C1 = Standard control algorithm.
C3 = Aggressive control algorithm (Default. Can
cause overshooting.)
M20514
SYSTEM
Cool
Off
Heat
Auto
On
FAN
Hold
Select
TUE
PM
AA BATTERIES (3)
M12582A
SET
HT.
M12583
M12584A
M12589A
M12588A
M14691