Cooling System (CT8775C Only) CAUTION Equipment Damage Hazard. Can cause permanent damage to compressor or other equipment. Do not operate cooling when outside temperature is below 50°F (10°C). Allow compressor to remain off for five minutes before restarting. See equipment manufacturer instructions. ❑ Slide the system switch to Cool and the Fan switch to Auto. ❑ Turn the dial counterclockwise to lower the temperature setting several degrees below the room temperature. NOTE: If a call for cooling is made before the compressor has been off for five minutes, or if a power interruption occurs while the compressor is running, the thermostat will go into a five-minute delay to protect the compressor. The snowflake will flash during this delay. ❑ After five minutes, the thermostat will display a solid snowflake to indicate the thermostat has called for cooling. The cooling system should turn on. ❑ Turn the dial clockwise to raise the temperature setting above the room temperature. ❑ The snowflake will disappear from the display to indicate the thermostat has ended the call for cooling. The cooling system should turn off. Fan (CT8775C Only) ❑ Slide the system switch to Off and the fan switch to On. The fan should run continuously. ❑ Slide the Fan switch to Auto. The fan should turn off. 69-1676-1 14