Honeywell CT8775A Owner's Manual - Page 9

Table 2. Terminal Designations on Old and New Thermostats., on CT8775A

Page 9 highlights

Table 2. Terminal Designations on Old and New Thermostats. Terminal on Old Thermostat R Rh (see Note 1) 4 V Rc R (see Note 1) W, W1, H Y, Y1, M G, F O B (see Note 3) C (see Note 4) X (see Note 4) B (see Note 3) W2, H2 Y2 Connect to Terminals Connect To Terminals on CT8775A on CT8775C R R (see Note 2) Power Description - W - - - - Do not connect. Rc (see Note 2) W Y G O B (see Note 3) Do not connect. Power for cooling Heat Cooling Fan Changeover in cool. (Single stage heat pump only). Changeover in heat. (Single stage heat pump only). Transformer common Do not continue Do not continue Second stage heat. installation. Call 1-800468-1502. installation. Call 1-800468-1502. Second stage cool. NOTES: 1. If wires were connected to both Rh and R terminals on the old thermostat, remove jumper between R and Rc on the new thermostat and connect Rh to R and R to Rc. 2. If wires will be connected to both R and Rc on the new thermostat, remove jumper between R and Rc. 3. Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B with electri- cal tape and do not use. 4. Tape off wire with electrical tape and do not use. 9 69-1676-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

9
69-1676±1
Table 2. Terminal Designations on Old and New Thermostats.
NOTES:
1.
If wires were connected to both Rh and R terminals on the old thermostat, remove jumper between R and Rc on
the new thermostat and connect Rh to R and R to Rc.
2.
If wires will be connected to both R and Rc on the new thermostat, remove jumper between R and Rc.
3.
Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B with electri-
cal tape and do not use.
4.
Tape off wire with electrical tape and do not use.
Terminal on
Old
Thermostat
Connect to Terminals
on CT8775A
Connect To Terminals
on CT8775C
Description
R
Rh
(see Note 1)
4
V
R
R
(see Note 2)
Power
Rc
R
(see Note 1)
±
Rc
(see Note 2)
Power for cooling
W, W
1
, H
W
W
Heat
Y, Y
1
, M
±
Y
Cooling
G, F
±
G
Fan
O
±
O
Changeover in cool. (Single stage heat pump
only).
B
(see Note 3)
±
B
(see Note 3)
Changeover in heat. (Single stage heat pump
only).
C
(see Note 4)
X
(see Note 4)
B
(see Note 3)
Do not connect.
Do not connect.
Transformer common
W
2
, H
2
Do not continue
installation. Call 1-800-
468-1502.
Do not continue
installation. Call 1-800-
468-1502.
Second stage heat.
Y
2
Second stage cool.