Honeywell HE360A Owners Manual - Page 10
Caution - filter
View all Honeywell HE360A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
HE360A,B POWERED FLOW-THROUGH HUMIDIFIER Connecting the Plumbing Use hot or cold water and either hard or softened water in the humidifier. 1. Shut off the water. CAUTION Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. Do not use gas line. 2. Use the self-piercing saddle valve (included) to tap into the water supply line at the location selected. See Fig. 5. If tapping into galvanized pipe, drain line and pre-drill 3/17 in. tap for saddle valve. The saddle valve is not designed to regulate water flow. The valve is either open or closed. IMPORTANT To prevent debris from clogging the solenoid in-line filter, be sure to install the saddle valve handle pointing toward the ceiling. SCREW DRIVER WATER LINE M20175 Fig. 5. Installing the saddle valve. 3. Use 1/4 in. (6 mm) OD tubing and connect the saddle valve to the inlet side of the solenoid valveon the humidifier (see Fig. 6). a. Place the brass compression nut over the tubing. b. Install brass insert into end of tubing. c. Slide the plastic compression ring over the tubing. (Discard copper compression ring provided with valve.) 69-1176-04 10