Honeywell HE360A Owners Manual - Page 8
Installing the Humidifier - wiring
View all Honeywell HE360A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
RETURN RETURN HORIZONTAL RETURN RETURN DFOLWON HIGHBOY LOWBOY M12808B Fig. 2. Selecting duct location for humidistat. Locating Closest 120V Electrical Outlet • Select location with access to an outlet. If not available, contact an electrician to have one installed. • Make sure that the humidifier cord is adequate to reach from the humidifier to the outlet. • Make sure that the 20 ft (6.2m) of thermostat wire is adequate to reach from the humidifier solenoid, to the sail switch, to the humidistat. Installing the Humidifier WARNING Hazardous Voltage Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning or electrical accessory. CAUTION Sharp Edges Installation Hazard. Can cause personal injury. Wear gloves and safety glasses. 1. Position the securing clips as shown in Fig. 3. CLIP CLIP M12813 Fig. 3. Position securing clips.