13 Light Pen Parameters ³ 415524 ³ 116917 Enable Light Pen Mode - Select this option if the scanner will be used in place of a light pen. It provides light pen emulation of each bar code scanned. * Bars High ³ 116907 Spaces High ³ 116916 Transmit as Code 39 - All bar codes will be decoded then transmitted as Code 39 bar codes. ³ 116906 * Transmit as Scanned - All bar codes will be decoded and transmitted in that symbology. ³ 116915 Poll Light Pen Source - The scanner waits for an active source voltage before transmitting data. ³ 116905 * Do Not Poll Light Pen Source ³ 116911 Enable Inverted IDLE/Extra Toggle - The scanner beeps and toggles the light pen data line with an extra data pulse to condition the decoder. ³ 116901 * Disable Inverted IDLE/Extra Toggle ³ 116910 Enable Pre-Transmit Toggle of RTS Line ³ 116900 * Disable Pre-Transmit Toggle of RTS Line 13-1