Honeywell WAVE2EX Setup Guide - Page 10
Connecting AlarmNet 7845CV2, Configuring Long Range Radio and Internet Communication Devices - ademco s
UPC - 781410215504
View all Honeywell WAVE2EX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
LYNXR-I Installation and Setup Guide LRR/IP Communications Device 24-Hour Standby Power If you are installing the AlarmNet 7845GSM/7845i-GSM or 7845i-L you must install the Super High Capacity battery P/N WALYNX-RCHB-SHA in the LYNXR-I. The 7845i-ENT/7845i and 7845CV2 can not be used for installations requiring 24-hour standby. AlarmNet 7845CV2 1. Connect the 4-wire communications cable to the LRR/IP communications port on the LYNXR-I. 2. Connect the four wires to the 7845CV2 as shown below: 4-WIRE CABLE (N4632-4) BATTERY ADEMCO K4362 YEL RED BLK GRN DATA OUT NC +12 VDC GND DATA IN LRR/IP COMMUNICATIONS PORT LYNXR-I CONTROL PANEL RED BLK YEL GRN LYNX STANDARD CAPACITY BATTERY Connecting AlarmNet 7845CV2 P1 BAT V+ GND Z1/DATA IN RAD FLT/ DATA OUT TB1 7845CV2 07000-011-V2 Configuring Long Range Radio and Internet Communication Devices 1. Enable the communications device in programming field *55 and configure alarm reporting and module supervision in programming field *77. 2. Program the device as required using the 7720P programmer (refer to the Installation Instruction for the device that you are installing for additional information). Note that the device address must be set to 3. 1. When programming an AlarmNet 7845CV2 the radio's "current limit" most option must be set to [Y] (yes). 2. The device must be registered before downloading or alarm reporting can take place. - 10 -