Hunter 44860 Owner's Manual

Hunter 44860 Manual

Hunter 44860 manual content summary:

  • Hunter 44860 | Owner's Manual - Page 1
    Hunter Fan 2500 Frisco Ave. Memphis, TN 38114 888-830-1326 www.hunterfan.com
  • Hunter 44860 | Owner's Manual - Page 2
    Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool installation and operation manual
  • Hunter 44860 | Owner's Manual - Page 3
    SETTINGS MENU 27 USER SETTINGS MENU 31 TEMPERATURE RANGE 34 ENERGY STAR DEFAULT PROGRAMS 35 MANUAL OPERATION 36 PROGRAM OPERATION 39 PROGRAM OVERRIDES 46 ADDITIONAL FEATURES 56 CLEAN SCREEN 56 CHANGE FILTER 60 ENERGY MONITOR FUNCTION 64 TROUBLESHOOTING 68 WIRING DIAGRAMS 72  44002-01
  • Hunter 44860 | Owner's Manual - Page 4
    Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool Congratulations! Thank you for choosing a Hunter programmable thermostat. Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation
  • Hunter 44860 | Owner's Manual - Page 5
    This thermostat is designed to work on the following heating and cooling systems: Up to 2 Stage Heat/2 Stage Cool Heat Only or Cool Only Systems Single and Multi-Stage Heat Pumps Gas, Electric or Oil Systems Millivolt Systems 2-wire Hydronic Systems AC or Hard-wired This thermostat is
  • Hunter 44860 | Owner's Manual - Page 6
    RC Y G W RC Y G W w NOTICE OF CAUTION! DO NOT disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper connection. 44002-01 r051807 
  • Hunter 44860 | Owner's Manual - Page 7
    RC Y G W RC Y G W  44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 8
    the main power panel or at the furnace. (Failure to turn off the power to the existing thermostat before removal could damage your system.) 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must
  • Hunter 44860 | Owner's Manual - Page 9
     44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 10
    existing terminal designation for proper identification. If wires marked "Y" or "C" are both present, "C" may be a Common wire and provides 24 VAC power to the unit. Connecting it greatly extends battery life. If there is no "C" wire, the thermostat will run on battery power. 44002-01 r051807 
  • Hunter 44860 | Owner's Manual - Page 11
    Y1 / Y2 Cooling Stage 1 or 2 Y1 Y2 Y2 Y1 R/RC R / RC Cooling Transformer Power Supply R/RC W1 / W2 Heating Stage 1 or 2 W1 W2 W2 W1 C C 24 VAC Common (if available) C G G Fan G RH RH Heating Transformer Power Supply RH See pages 72-73 for a complete wiring diagram. 10 44002
  • Hunter 44860 | Owner's Manual - Page 12
    : HEAT PUMP SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Compressor Stage 1 or 2 Y1 Y2 Y2 Y1 C 24 VAC Common C C O W2 Auxilliary Heat W2 W2 O Cool Mode Powered Reverse Valve O G Fan G G E Emergency Heat
  • Hunter 44860 | Owner's Manual - Page 13
    G RC W 12 Y Y1 Y2 W3 W2 G RH RCR B W1 E O C L 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 14
    by gently pulling the wall plate from the back of the thermostat. 2. Position the new wall plate on the wall horizontally and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter thermostat wall plate or, if there are no existing holes, visually level
  • Hunter 44860 | Owner's Manual - Page 15
    G RC W 14 Y 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 16
    marked. 5. Tap the plastic anchors into the holes until they are flush with the wall. 6. Reposition the wall plate on the wall, pulling the wires through the wall plate opening. Insert the mounting screws through the wall plate and into the anchors. Verify that the wall plate is level. Securely
  • Hunter 44860 | Owner's Manual - Page 17
    Terminal Shield Terminal Screw Jumper Wire 16 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 18
    RH and RC terminals for systems that do not have both an RH and RC wire. If you have both an RH and RC wire, remove this jumper; otherwise, leave the jumper in place. 2. Complete wiring diagrams for Conventional HVAC Systems and Heat Pump Systems are provided on pages 72-74. Match and connect the
  • Hunter 44860 | Owner's Manual - Page 19
    18 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 20
    it over the terminal and battery openings. Press the thermostat to the wall plate and it will snap into place. NOTE: Do not force the thermostat onto the wall plate as this may damage the terminal pins. If the thermostat does not snap into place easily, the unit may not work. 3. Restore power at the
  • Hunter 44860 | Owner's Manual - Page 21
    MAY 17 2006 THURSDAY 20 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 22
    GENERAL OPERATING INSTRUCTIONS Your new Hunter thermostat is easy to program and use. The front of the thermostat is a touch screen that responds to the pressure of a finger. You can program the thermostat to automatically readjust the temperature and airflow to settings that you choose or you can
  • Hunter 44860 | Owner's Manual - Page 23
    DATE & TIME SETTINGS DATE, MONTH, YEAR MTAHYU R117S 2006 DAY 2 3 22 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 24
    1. Touch either the month, date, year at the top of the touch screen. 2. Touch the or sign to adjust the setting. 3. Repeat Steps 1-2 for each setting. Touch to return to the main screen. 44002-01 r051807 23
  • Hunter 44860 | Owner's Manual - Page 25
    CLOCK 24 MAY 17 2006 THURSDAY 1 2 3 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 26
    flashes. Note the AM & PM indicators. 2. Touch the or sign to adjust the setting. 3. Repeat Steps 1-2 to adjust the minutes setting. Touch screen. to return to the main NOTE: The clock can be set to automatically adjust for Daylight Savings Time in the USER SETTINGS MENU, see pages 31-33. 44002
  • Hunter 44860 | Owner's Manual - Page 27
    (Option 10) set to 0, stages 2 and 3 will be controlled by the SPAN setting only. If the stage timer is set to 30, the system will turn on the next stage based on the SPAN setting or 30 minutes, which ever comes first. Span settings remain the same for
  • Hunter 44860 | Owner's Manual - Page 28
    installer can set SYSTEM functions once the thermostat is installed. The default settings are shown in bold in the following list. Options are listed inside the parentheses. Example: the default SYSTEM TYPE is CONVENTIONAL with (HEAT PUMP (0, 30) 8. RESIDUAL COOLING TIMER: 30 seconds (0, 30, 60,
  • Hunter 44860 | Owner's Manual - Page 29
    SYSTEM SETTINGS MENU (CONT'D) SYS3TEM or USER 27 1 5 468 28 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 30
    of the touch screen. 2. Press and hold for 3 seconds for SYSTEM and USER settings to appear. 3. Touch SYSTEM. The selected word flashes. 4. Touch . 5. Scroll through the first setting with the or sign to select an option. Refer to the list on page 27 for setting options. 6. Touch to confirm
  • Hunter 44860 | Owner's Manual - Page 31
    to 0, the thermostat operates as a digital non-programmable thermostat. The FILTER CHANGE INDICATOR (Option 2) runs in calendar days and can be set from 30-360 days in 15-day increments (the default is 90). The REFRESH FAN ON (Option 3) function runs only the fan during heating or cooling off cycles
  • Hunter 44860 | Owner's Manual - Page 32
    also set certain functions in the USER SETTINGS MENU. The default settings are shown in bold in the following list. Options are listed inside the parentheses. Example: the default PROGRAMS PER DAY is 4 Periods with (0 and 2) as options. See pages 32-33 to change these settings. 1. PROGRAMS PER DAY
  • Hunter 44860 | Owner's Manual - Page 33
    USER SETTINGS MENU (cont'd) SYSTEM or US3ER 27 1 5 468 32 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 34
    of the touch screen. 2. Press and hold for 3 seconds for SYSTEM and USER settings to appear. 3. Touch USER. The selected word flashes. 4. Touch . 5. Scroll through the first setting with the or sign to select an option. Refer to the list on page 31 for setting options. 6. Touch to confirm
  • Hunter 44860 | Owner's Manual - Page 35
    for energy efficiency. By using the preprogrammed and default settings, this thermostat can save you money by optimizing energy usage in heating and cooling. 30o F (0o C) 45o F (7o C) 95o F (35o C) 99o F (37o C) Out of Range "LO" 99o F 34
  • Hunter 44860 | Owner's Manual - Page 36
    by pressing the icon in the program mode. 10 pm Program 4 Heat : 60o F (16o C) Cool : 82o F (28oC) Program 3 Heat : 68o F (20o C) Cool : 78o F (26o C) 4 pm 6 am Program 1 Heat : 68o F (20o C) Cool : 78o F (26o C) 8 am Program 2 Heat : 60o F (16o C) Cool : 85o F (29o C) 44002-01 r051807 35
  • Hunter 44860 | Owner's Manual - Page 37
    MANUAL OPERATION Many people prefer to operate their thermostats manually, adjusting settings as needed. NOTE: PROGRAMS PER DAY must be set to 0 for manual operation. See USER SETTINGS MENU (pages 31-33). SET HEAT OR AC SYSTEM MODE MAY 17 2006 THURSDAY 1 2 3 5 6 47 36 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 38
    area of the touch screen. SELECT FUNCTION appears. 2. Touch the or icon. SET SYSTEM MODE appears. 3. Scroll through the settings with the or sign to select one of the SYSTEM modes: HEAT ( icon, red screen) EMHEAT (only for Heat Pump Systems) AUTO ( and icons) COOL ( icon, blue screen) OFF (no
  • Hunter 44860 | Owner's Manual - Page 39
    38 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 40
    of 1°F (1°C). After 15 seconds of inactivity during programming, the thermostat returns to the main display. Press to exit Program Mode at any time. To review any existing programs, touch any period icon to see selections. PERIOD ICONS The program periods are indicated by the following icons
  • Hunter 44860 | Owner's Manual - Page 41
    CREATING CUSTOM PROGRAMS (cont'd) This thermostat has an autorecovery function and will automatically calculate the time needed to achieve the temperature you set. Therefore, it will be at the temperature you select at the time you select. (Step 7, page 41). 4 5 7 6 23 8 1 P1 40 44002-01
  • Hunter 44860 | Owner's Manual - Page 42
    screen to begin programming. SELECT FUNCTION appears at the top of the display. (Image P1) 2. Touch the icon. PRESS PRG TO PROGRAM appears at the top of the display along with the days of the week. NOTE: Either 2 or 4 PERIOD icons will display depending upon how many were selected in USER SETTINGS
  • Hunter 44860 | Owner's Manual - Page 43
    CREATING CUSTOM PROGRAMS (cont'd) SELECT ICON TO PROGRAM 11 9 12 10 13 P2 42 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 44
    mode (ON, AUTO, or REFRESH). 12. Touch to save the settings for the selected days/period and to select new days/period for programming. 13. Repeat instructions 1-12 to select new days and time periods to be programmed or press to save programs and return to the main display. 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 45
    FAN PROGRAM MODE 2 MAY 17 2006 THURSDAY 1 3 4 44 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 46
    blank area of the touch screen. SELECT FUNCTION appears. 2. Touch the icon. SET FAN TO PROGRAM MODE appears. 3. Scroll through the fan settings with the or sign to select one of the fan modes: ON: Fan runs continuously regardless of the system mode. AUTO: Fan runs when the system is on. REFRESH
  • Hunter 44860 | Owner's Manual - Page 47
    PROGRAM OVERRIDES You can either temporarily override the settings for the current program, or permanently override all settings and adjust temperatures manually. TEMPORARY OVERRIDE SETTINGS SELECT HOLD TYPE 6 1 2 4 7 358 46 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 48
    the or sign to adjust the setting. 3. Press and the screen displays SELECT HOLD TYPE. 4. Touch the or sign to select TEMPORARY HOLD. 5. Press and the screen displays TEMPORARY HOLD - HOLD UNTIL. 6. Touch the hour and minutes 7. Use the or sign to set the ending time. 8. Press and the main
  • Hunter 44860 | Owner's Manual - Page 49
    PERMANENT OVERRIDE SETTINGS SELECT HOLD TYPE 1 2 4 35 48 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 50
    the temperature icon ( ). The selected icon will flash and SET OVERRIDE TEMPERATURE appears. 2. Touch the or sign to adjust the setting. 3. Press and the screen displays SELECT HOLD TYPE. 4. Touch the or sign to select PERMANENT HOLD. 5. Press and the main display shows HOLD. 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 51
    VACATION OVERRIDE SETTINGS SELECT HOLD TYPE 6 1 3 5 246 50 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 52
    will flash and SET OVERRIDE TEMPERATURE appears. 2. Press and screen displays SELECT HOLD TYPE. 3. Touch the or sign to select VACATION HOLD. 4. Press and the main display shows VACATION HOLD. SET NUMBER OF DAYS. Numeral flashes. 5. Touch the or sign to adjust the number of days. 6. Press
  • Hunter 44860 | Owner's Manual - Page 53
    CANCEL TEMPERATURE OR HUMIDITY HOLD MAY 17 2006 THURSDAY 1 2 52 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 54
    1. Touch the icon. CANCEL TEMPERATURE HOLD appears. 2. Press , the hold is released and main display returns. NOTE: If the Temperature is touched and override screens appear but no changes are made, the HOLD remains and the main display returns. 44002-01 r051807 53
  • Hunter 44860 | Owner's Manual - Page 55
    HOME TODAY FUNCTION HOME TODAY overrides the program settings for periods , and with comfortable heat or cool settings while you are home. HOME TODAY ends when period begins. MAY 17 2006 THURSDAY 1 2 3 4 54 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 56
    a blank area of the touch screen. 2. Touch the 3. Touch the TODAY. 4. Touch icon. or sign to toggle between SET HOME TODAY and CANCEL HOME to return to the main display. The icon will show on the main screen if it is activated. 5. Touch the icon and press to deactivate the HOME TODAY feature
  • Hunter 44860 | Owner's Manual - Page 57
    ADDITIONAL FEATURES The CLEAN SCREEN FUNCTION allows 30 seconds to clean the touch screen without disturbing the existing settings. CLEAN SCREEN PRESS ENTER FOR CLEANING 1 2 3 56 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 58
    a blank area of the touch screen. 2. Touch . PRESS ENTER FOR CLEANING appears. 3. Press to return to the main screen. A 30-second countdown begins to allow time to clean the touch screen. 4. Use a damp cloth with a non-corrosive solvent such as water or a household glass cleaner to clean the
  • Hunter 44860 | Owner's Manual - Page 59
    LOCK FUNCTION The lock function allows a user to lock the touch screen to prevent unexpected or accidental changes. MAY 17 2006 THURSDAY 35 1 4 2 6 7 58 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 60
    the setting. 5. Repeat 3-4 for each digit. 6. Touch to return to the menu screen. 7. Touch to confirm code and return to main screen. The icon will appear on the main screen. NOTE: Once a code is set, touching the function on the main screen will bring the user to ENTER CODE TO UNLOCK. Enter
  • Hunter 44860 | Owner's Manual - Page 61
    indicator icon will flash after the filter life counter expires as a reminder to check or change your HVAC filter. Reset the filter function after you have changed the filter. The filter change counter is set in the USER SETTING MENU for a period of 30-360 days. FILTER RUN TIME HOLD FILTER KEY TO
  • Hunter 44860 | Owner's Manual - Page 62
    blank area of the touch screen. 2. Touch . FILTER RUN TIME and HOLD FILTER KEY TO RESET appear on the display. 3. Touch and hold for 3 seconds for time to reset. (Pressing the filter button for less than 3 seconds will cause the Filter indicator icon to continue to appear.) 4. Press to return
  • Hunter 44860 | Owner's Manual - Page 63
    thermostat enters the second battery power shortage mode. When no battery power is left, the BATTERIES USED UP warning flashes on the display and the system turns off. The system remains off until new batteries are installed. The thermostat resumes normal operation after new batteries are installed
  • Hunter 44860 | Owner's Manual - Page 64
    RECOVERY The AUTO RECOVERY FUNCTION allows heating and cooling systems to gradually recover from an energy-saving set point temperature to a comfort set point temperature. AUTO RECOVERY calculates the time needed to adjust the temperature to the next program setting. When the thermostat is in AUTO
  • Hunter 44860 | Owner's Manual - Page 65
    ENERGY MONITOR FUNCTION The ENERGY MONITOR function allows you to review and monitor the effect of your program settings on the system runtime. MAY 17 2006 THURSDAY 1 3 24 5 64 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 66
    area of the touch screen. 2. Touch the icon. 3. Scroll through the SYSTEM RUNTIME settings with the or sign to see the system runtime in hours for TODAY, YESTERDAY, the CURRENT MONTH or the LAST MONTH. 4. Touch and hold the icon for 3 seconds to reset the counters. 5. Touch to return to the
  • Hunter 44860 | Owner's Manual - Page 67
    mode indicates an expected operation problem. The screen flashes a SYSTEM ERROR message and shuts the system off. You must reset and the thermostat by replacing the batteries if the thermostat has entered ERROR mode. AUTO CUT-OFF AUTO CUT OFF automatically turns the system off if the temperature
  • Hunter 44860 | Owner's Manual - Page 68
    COMPRESSOR PROTECTION After the system stops running in cooling mode, there is a 3.5 minute delay before it can be restarted to prevent compressor damage due to rapid cycling. RESETTING THE UNIT To restore the thermostat to the original factory settings, enter the SYSTEM SETTINGS MENU and set Option
  • Hunter 44860 | Owner's Manual - Page 69
    Check the batteries and battery connections. 1b. Reset the thermostat. 2. The auto fan feature does not operate properly. 2a. Check to see if the correct furnace type is selected under the system settings in options. 3. My display is erratic. 3a. Replace the batteries. 4. The program will not change
  • Hunter 44860 | Owner's Manual - Page 70
    is closed properly. 5f. If your system has 4 wires, ensure the jumper is installed between the RC and RH terminals. 6. The display comes on but does not stay illuminated. 6a. Replace batteries. 7. My system continues to operate when the thermostat is in the off position. 7a. Replace unit. 44002
  • Hunter 44860 | Owner's Manual - Page 71
    8. The touch screen permanently reads SYSTEM ERROR. 8a. Refer to page 66 for ERROR mode instructions. If ERR message remains after battery replacement, then replace unit. 9. How do I just operate my thermostat manually? 9a. Manual operation instructions begin on page 38. 70 44002-01 r051807
  • Hunter 44860 | Owner's Manual - Page 72
    NEED MORE HELP? Is there help on the web? Yes, visit us at http://www.hunterfan.com for more information. Is there someone I can call? Yes. The Hunter Technical Support is available from 7 am to 7 pm CST M-F and 8 am to 5 pm Saturday. They may be reached toll-free at 1-888-830-1326. 44002-01
  • Hunter 44860 | Owner's Manual - Page 73
    WIRING DIAGRAMS Number of wires connected depends on the HVAC system requirement. • 4-wire Heat/Cool System (single stage): RH (jumper between RH and Rc/R), Y1, W1, G • 5-wire Heat/Cool System (single stage): RH, Rc/R (remove jumper between RH and RC/R), Y1, W1 G. • 2-wire Heat only (single stage):
  • Hunter 44860 | Owner's Manual - Page 74
    Optional Jumper Conventional HVAC Systems RH RC/R C Y1 Y2 W1 W2 G Heat 24V Cool 24V Supply Supply Cool Cool Heat Heat Fan Stage 1 Stage 2 Stage 1 Stage 2 Control 24VAC Common (if available) 44002-01 r051807 73
  • Hunter 44860 | Owner's Manual - Page 75
    W2 E O B G L 24VAC Supply Compressor Compressor Auxiliary Emergency Reversing Valve Reversing Valve Fan System Stage 1 Stage 2 Heat Heat Cool Heat Control Monitor 24VAC Common (if available) Number of wires connected depends on the heat pump system requirement. Not all terminals need
  • Hunter 44860 | Owner's Manual - Page 76
    44002-01 r051807 75
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

Hunter Fan
2500 Frisco Ave.
Memphis, TN 38114
888-830-1326
www.hunterfan.com