Hunter 44860 Owner's Manual - Page 73
wire Heat/Cool System single stage: RH jumper between RH and Rc/R
View all Hunter 44860 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
WIRING DIAGRAMS Number of wires connected depends on the HVAC system requirement. • 4-wire Heat/Cool System (single stage): RH (jumper between RH and Rc/R), Y1, W1, G • 5-wire Heat/Cool System (single stage): RH, Rc/R (remove jumper between RH and RC/R), Y1, W1 G. • 2-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1 • 3-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1, G • 3-wire Cool only (single stage): RH (jumper between RH and Rc/R), Y1, G 72 44002-01 r051807
¶±
WIRING DIAGRAMS
Number of wires connected depends on the HVAC system requirement.
•
4-wire Heat/Cool System (single stage): RH (jumper between RH and Rc/R),
Y1, W1, G
•
5-wire Heat/Cool System (single stage): RH, Rc/R (remove jumper between RH
and RC/R), Y1, W1 G.
•
2-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1
•
3-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1, G
•
3-wire Cool only (single stage): RH (jumper between RH and Rc/R), Y1, G
44002-01 r051807