Husqvarna 520iHD60 Owner Manual - Page 14
Troubleshooting
View all Husqvarna 520iHD60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Troubleshooting Keypad Problem Possible faults Possible solution Green start LED flashes. Low battery voltage. Charge the battery. Red error LED flash- Overload. es. The cutting attachment is blocked. stop the product. Remove the battery. Clean the cutting attachment from unwanted materials. Loosen the chain. Temperature deviation. Let the product become cool. The power trigger and the start button are pushed at the same time. Release the power trigger and push the start button. The product does not Dirt in the battery connectors. start. Clean the battery connectors with compressed air or a soft brush. Red error LED comes on. It is necessary to do servicing on the product. Speak to your servicing dealer. Battery Problem Green LED flashes. Red error LED flashes. Red error LED comes on. Possible faults Low battery voltage. The battery is empty. Temperature deviation. Overvoltage. Cell difference is to much (1V). Possible solution Charge the battery. Charge the battery. Use the battery in temperatures between -10°C (14°F) and 40°C (104°F). Remove the battery from the battery charger. Speak to your servicing dealer. Battery charger Problem Red error LED flashes. Red error LED comes on. Possible faults Temperature deviation. Possible solution Use the battery charger in temperatures between 5 °C (41 °F) and 40 °C (104 °F). Speak to your servicing dealer. 14 773 - 004 - 19.08.2020