Troubleshooting User interface LED display Possible faults Battery LED indicator flashes or- Low battery voltage. ange Red error LED flashes Overload. The product does not start Error LED is lit with red light Temperature deviation. The power trigger and the activate button are pressed at the same time. Dirt in the battery connectors. The product needs servicing. Possible action Charge the battery. The cutting attachment is jammed. deactivate the product. Remove the battery. Clean the cutting attachment from unwanted materials. Let the product cool down. Release the power trigger and the product is active. Clean the battery connectors with compressed air or a soft brush. Contact your servicing agent. Transportation, storage and disposal Transportation and storage • The supplied Li-ion batteries obey the Dangerous Goods Legislation requirements. • Obey the special requirement on package and labels for commercial transportation, including by third parties and forwarding agents. • Speak to a person with special training in dangerous material before you send the product. Obey all applicable national regulations. • Use tape on open contacts when you put the battery in a package. Put the battery in the package tightly to prevent movement. • Remove the battery for storage or transportation. • Put the battery and the battery charger in a space that is dry and free from moisture and frost. • Do not keep the battery in an area where static electricity can occur. Do not keep the battery in a metal box. • Put the battery in storage where the temperature is between 5°C/41°F and 25°C/77°F and away from open sunlight. • Put the battery charger in storage where the temperature is between 5 °C/41 °F and 45°C/113°F and away from open sunlight. 18 1938 - 003 - 24.02.2023