Husqvarna RZ5424 Kawasaki Owners Manual - Page 29

Jumper Cables Use, To remove cables, reverse order

Page 29 highlights

OPERATION Weak Battery WARNING! Lead-acid batteries generate explosive gases. Keep sparks, flame and smoking materials away from batteries. Always wear eye protection when around batteries. IMPORTANT INFORMATION The mower is equipped with a 12-volt negative grounded system. The other vehicle must also be a 12-volt negative grounded system. Do not use the mower to start other vehicles. IMPORTANT INFORMATION Refer to the EFM Information Sheet from the unit literature packet for specific jump starting instructions. If the battery is too weak to start the engine, it should be recharged. (See Battery in the Maintenance section.) Jumper Cables Use 1. Connect each end of the RED cable to the POSITIVE (+) terminal on each battery, taking care not to short against chassis. 2. Connect one end of the BLACK cable to the NEGATIVE (-) terminal of the fully charged battery. 3. Connect the other end of the BLACK cable to a good CHASSIS GROUND on the mower with the discharged battery, away from the fuel tank and battery. To remove cables, reverse order 1. Remove BLACK cable first from chassis and then from the fully charged battery. 2. Remove RED cable last from both batteries. Jumper cable connection 8011-642 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

OPERATION
29
WARNING!
Lead-acid batteries generate
explosive gases. Keep sparks, flame
and smoking materials away from
batteries. Always wear eye protection
when around batteries.
Weak Battery
8011-642
Jumper cable connection
IMPORTANT INFORMATION
The mower is equipped with a 12-volt negative
grounded system. The other vehicle must also
be a 12-volt negative grounded system. Do not
use the mower to start other vehicles.
If the battery is too weak to start the engine, it should
be recharged. (See
Battery
in the
Maintenance
section.)
Jumper Cables Use
1.
Connect each end of the RED cable to the
POSITIVE (+) terminal on each battery, taking
care not to short against chassis.
2.
Connect one end of the BLACK cable to the
NEGATIVE (-) terminal of the fully charged battery.
3.
Connect the other end of the BLACK cable to a
good CHASSIS GROUND on the mower with the
discharged battery, away from the fuel tank and
battery.
To remove cables, reverse order
1.
Remove BLACK cable first from chassis and then
from the fully charged battery.
2.
Remove RED cable last from both batteries.
IMPORTANT INFORMATION
Refer to the EFM Information Sheet from the
unit literature packet for specific jump starting
instructions.