IBM 436854u Service Guide - Page 242
System shutoff due to +3.3V over voltage, Reseat the following components
UPC - 883436026772
View all IBM 436854u manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 242 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. System-error log message Action System shut off due to system board under temperature 1. Make sure that the fans have good airflow and are not obstructed. 2. (Trained service technician only) Replace the system board. System shutoff due to +12V over voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to +12V under voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to +2.5V over voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to +2.5V under voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to +3.3V over voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to +3.3V under voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to 1.5V CPU over voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to 1.5V CPU under voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. 224 System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide