IBM IC25N020ATDA04 Hard Drive Specifications - Page 151
Initialize Device Parameters 91h, Another Initialize Device Parameters command is received.
View all IBM IC25N020ATDA04 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 151 highlights
13.12 Initialize Device Parameters (91h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature Sector Count V V V V V V V V Sector Number Cylinder Low Cylinder High Device/Head 1 - 1 D H H H H Command 1 0 0 1 0 0 0 1 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error See Below Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status See below Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 7 6 5 4 3 2 10 BSY RDY DF DSC DRQ COR IDX ERR 0 0 0 - - 0 -V Figure 91. Initialize Device Parameters command (91h) The Initialize Device Parameters command enables the host to set the number of sectors per track and the number of heads minus 1, per cylinder. Words 54-58 in Identify Device Information reflects these parameters. The parameters remain in effect until the following events occur: ! Another Initialize Device Parameters command is received. ! The device is powered off. ! A hard reset occurs. ! A soft reset occurs and the Set Feature option of CCh is set instead of 66h. Output Parameters To The Device Sector Count H This indicates the number of sectors per track. Zero (0) indicates that there are no sectors per track. This indicates the number of heads minus 1 per cylinder. The minimum is 0 and the maximum is 15. Travelstar 48GH, 30GN & 15GN hard disk drive specifications 137