Register initialization, Cylinder Low
View all IBM IC25N020ATDA04 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
11.1.1 Register initialization After a power on, a hard reset, or a software reset, the register values are initialized as shown in the table below. Register Error Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status Alternate Status Default Value Diagnostic Code 01h 01h 00h 00h A0h 50h 50h Figure 60. Default Register Values As a result of carrying out an Execute Device Diagnostic command or being powered on, or if a hard reset occurs - the system generates an Error Register diagnostic code. See the table below for a description of the various codes. Code 01h 02h 03h 04h 05h 8xh Description No error detected Formatter device error Sector buffer error ECC circuitry error Controller microprocessor error Device 1 failed Figure 61. Diagnostic Codes Travelstar 48GH, 30GN & 15GN hard disk drive specifications 79