Icom IC-7410 Service Manual - Page 19

Adjustment Procedure, Preparation

Page 19 highlights

SECTION 4. ADJUSTMENT PROCEDURE 4-1 PREPARATION ¤ REQUIRED EQUIPMENTS EQUIPMENT GRADE AND RANGE EQUIPMENT GRADE AND RANGE Short plug Modified 3.5 mm (1/8'') monoral plug (See the illust below) Audio generator (AG) Frequency range : 300-3000 Hz Output level : 1-500 mV RF voltmeter Measuring range : 20-200 mV (50 Ω terminated) Frequency range : 0.1-50 MHz AC Millivoltmeter Measuring range : 10 mV to 10 V RF power meter (50 Ω terminated) Measuring range Frequency range SWR : 5-120 W : 0.1-50 MHz : Less than 1.2 : 1 Digital multimeter Measuring range : 0-10 V (Voltage) 1-30 A (Current) Input impedance : More than 50 kΩ Frequency range : 0.1-100 MHz Frequency counter Frequency accuracy : ±1 ppm or better Input level : Less than 1 mW External speaker Input impedance : 8 Ω Capacity : More than 2 W Standard signal generator (SSG) Frequency range Output level : 0.1-100 MHz : 0.1 mV to 32 mV Spectrum Analyzer Frequency range : At least 90 MHz Bandwidth : 100 kHz (-127 to -17 dBm) Dummy Loads Impedance : 50 Ω and 100 Ω/120 W CAUTION!: SAVE the originally programmed contents (Memory channel contents, set mode settings, etc.), before starting adjustment. When all adjustments are completed, these contents in the transceiver may be cleared. ¤ GENERAL CONNECTION AND UNIT LOCATION AC millvolt Audio meter generator [MIC] [MIC] AC MILLIVOLT METER (10 mV to 10 V) - EXT. SPEAKER (2 W/8 Ω) - MAIN UNIT PTT PLL RF-A UNIT UNIT • Short plug (For entering the adjustment mode) CTRL UNIT 3.5 mm (1/8'') monoral plug (Short) + [EXT-SP] [REMOTE] [DC 13.8V] [ANT1] RF POWER METER (120 W/50 Ω) + DC power supply (13.8 V/30 A) −⊕ 3.5(d) mm monoral plug AMMETER (0.1-30 A) Fuses 30 A Supplied DC cable ⊕ Red − Black − ⊕Red − Black DUMMY LOAD (50 Ω/120 W) FREQUENCY COUNTER (0.1-1 GHz) ATTENUATOR (40/50 dB/100 W) STANDARD SIGNAL GENERATOR (0.1-60 MHz) NEVER TRANSMIT while an SG is connected. 4 - 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

4 - 1
SECTION 4
.
ADJUSTMENT PROCEDURE
¤
GENERAL CONNECTION AND UNIT LOCATION
¤
REQUIRED EQUIPMENTS
4-1 PREPARATION
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
Short plug
Modified 3.5 mm (1/8’’) monoral plug
(See the illust below)
Audio generator
(AG)
Frequency range : 300–3000 Hz
Output level
: 1–500 mV
RF voltmeter
(50
Ω
terminated)
Measuring range
: 20–200 mV
Frequency range
: 0.1–50 MHz
AC Millivoltmeter
Measuring range : 10 mV to 10 V
RF power meter
(50
Ω
terminated)
Measuring range
: 5–120 W
Frequency range
: 0.1–50 MHz
SWR
: Less than 1.2 : 1
Digital multimeter
Measuring range : 0–10 V (Voltage)
1–30 A (Current)
Input impedance : More than 50 k
Ω
Frequency counter
Frequency range
: 0.1–100 MHz
Frequency accuracy : ±1 ppm or better
Input level
: Less than 1 mW
External speaker
Input impedance : 8
Ω
Capacity
: More than 2 W
Standard signal
generator (SSG)
Frequency range
: 0.1–100 MHz
Output level
: 0.1 mV to 32 mV
(–127 to –17 dBm)
Spectrum Analyzer
Frequency range : At least 90 MHz
Bandwidth
: 100 kHz
Dummy Loads
Impedance
:
50
Ω
and 100
Ω
/120 W
CAUTION!:
SAVE the originally programmed contents (Memory channel contents, set mode settings, etc.), before starting
adjustment. When all adjustments are completed, these contents in the transceiver may be cleared.
[DC 13.8V]
[MIC]
[EXT-SP]
[REMOTE]
[ANT1]
<Viewing from the BOTTOM side>
PLL
UNIT
MAIN UNIT
RF-A
UNIT
CTRL
UNIT
Audio
generator
PTT
[MIC]
AC millvolt
meter
DUMMY LOAD
(50
Ω
/120 W)
RF POWER METER
(120 W/50
Ω)
AMMETER
(0.1–30 A)
Fuses
30 A
DC power supply
(13.8 V/30 A)
Black
Red
Red
Black
Supplied DC cable
STANDARD SIGNAL GENERATOR
(0.1–60 MHz)
AC MILLIVOLT METER
(10 mV to 10 V)
EXT. SPEAKER
(2 W/8
Ω)
3.5(d) mm monoral plug
+
+
NEVER TRANSMIT
while an SG is connected.
FREQUENCY COUNTER
(0.1–1 GHz)
ATTENUATOR
(40/50 dB/100 W)
(Short)
• Short plug