¤ RECEIVE ADJUSTMENTS RX HF Reterns to the previous screen. MENU Starts the receiveadjustment. Stores the value and move to the next ite ADJUSTMENT ITEM PREPARATION TOTAL GAIN ADJUSTMENT TRANSCEIVER'S CONDITION OPERATION MEASURE POINT • Connect an SSG to [ANT1], and - then set it as; - Frequency : 14.1515 MHz Modulation : None Level : +20 dBu (-87 dBm) 1 • Display: "Total Gain HF POFF" - - • Receiving 2 • Display: "Total Gain HF PON" - - • Receiving EXTERNAL AGC 3 • Display: "AGC (HF)" • Receiving • Set the SSG as; - Level : +70 dBu (-37 dBm) S-METER NOTE: DO NOT change the output level of the SSG until the beep sounds. 4 • Display: "S0 Level HF" • Set the SSG as; - • Receiving Level : OFF 5 • Display: "S9 Level HF" • Receiving 6 • Display: "S9+60 Level HF" • Receiving • Set the SSG as; Level : +34 dBu (-73 dBm) • Set the SSG as; Level : +90 dBu (-17 dBm) Automatically returns to the receive adjustment menu. ADJUST POINT - - - - - VALUE - Push [F-5]. (Beeps sound 12 sec. later) Push [F-5]. (Beeps sound 12 sec. later) Push [F-5]. (Beeps sound 22 sec. later) Push [F-5]. (Beep sounds, and then anoter beep sounds 0.5 sec. later) Push [F-5]. (Beep sounds, and then anoter beep sounds 1 sec. later) 4 - 10