Page 29 highlights

5 OTHER FUNCTIONS Using the Emergency Call function (Continued) The transceiver enters the Emergency mode through the following functions, depending on a presetting: D The Stationary Detection function When the transceiver is detected as being stationary (no motion) for the ON Timer preset time� L If a user moves the transceiver during the Reminder Timer set time, the Emergency mode is canceled� Enters the Emergency mode. Sends an Emergency call. D The Motion Detection function When the transceiver continuously moves for the ON Timer preset time� L If a user holds down [Emer] for the Emer SW OFF Timer (Sec) set time, before the Reminder Timer set time expires, the Emergency mode is canceled� Enters the Emergency mode. Sends an Emergency call. Acceleration Acceleration ON Timer Reminder Timer Emergency Timer No motion is detected. Stationary Sensitivity Time If moving during the Reminder Timer, the Emergency mode is canceled. NOTE: The Stationary Detection function may not properly work, depending on the surrounding environment such as obstructions, weather condition, and so on� Icom is not responsible for the destruction or damage caused by using the Stationary Detection function� ON Timer Motion is detected. Reminder Timer [Emergency] Emergency Timer Motion Sensitivity Time If holding down [Emergency] during Reminder Timer, the Emergency mode is canceled. NOTE: The Motion Detection function may not properly work, depending on the surrounding environment such as obstructions, weather condition, and so on� Icom is not responsible for the destruction or damage caused by using the Motion Detection function� 5-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

5
OTHER FUNCTIONS
5-8
Acceleration
Time
Enters the
Emergency mode.
Sends an
Emergency call.
Stationary
Sensitivity
ON Timer
Reminder Timer
Emergency Timer
If moving during the Reminder
Timer, the Emergency mode
is canceled.
No motion is
detected.
Motion
Sensitivity
Acceleration
Enters the
Emergency mode.
Sends an
Emergency call.
Motion is
detected.
Time
ON Timer
Reminder Timer
Emergency Timer
[Emergency]
If holding down [Emergency]
during Reminder Timer, the
Emergency mode is
canceled.
The transceiver enters the Emergency mode through
the following functions, depending on a presetting:
D
The Stationary Detection function
When the transceiver is detected as being stationary
(no motion) for the ON Timer preset time�
L
If a user moves the transceiver during the
Reminder Timer set time, the Emergency mode is
canceled�
Using the Emergency Call function (Continued)
D
The Motion Detection function
When the transceiver continuously moves for the ON
Timer preset time�
L
If a user holds down [Emer] for the Emer SW OFF
Timer (Sec) set time, before the Reminder Timer
set time expires, the Emergency mode is canceled�
NOTE:
The Stationary Detection function may
not properly work, depending on the surrounding
environment such as obstructions, weather condition,
and so on�
Icom is not responsible for the destruction or damage
caused by using the Stationary Detection function�
NOTE:
The Motion Detection function may not
properly work, depending on the surrounding
environment such as obstructions, weather condition,
and so on�
Icom is not responsible for the destruction or damage