Insignia NS-FDRE44W1 User guide - Page 23

Risk Of Electric Shock, WIRE SYSTEM, CONNECTION, WIRE SYSTEM CONNECTION

Page 23 highlights

INSTALLATION INSTRUCTIONS NS-FDRE44W1/NS-FDRE44W1-C 4 Connect the other wires to the outer terminal block screws. Make sure that you cross the screws through the terminal rings, then tighten the screws. 5 Tighten the strain relief screws. 6 Insert the tab on the terminal block cover into your dryer's rear panel slot, then secure the cover with a screw. WARNING: We recommend using ring-type terminals. If you use strap terminals, make sure that they are tightened. WARNING: • Risk Of Electric Shock - All U.S. models are produced for a 3-WIRE SYSTEM CONNECTION. • The dryer frame is grounded to the neutral conductor at the terminal block. A 4-WIRE SYSTEM CONNECTION is required for new or remodeled construction, mobile homes, or if local codes do not permit grounding through neutral conductor. • If the 4-wire system is used, the dryer frame cannot be grounded to the neutral conductor at the terminal block. See to the "Electric requirements" on page 18 for 3-wire or 4-wire system connections. • Remove the terminal block cover plate. Insert the power cord with a UL-listed strain relief through the hose provided in the cabinet near the terminal block. A strain relief must be used. Do not loosen the nuts already installed on the terminal block. Be sure they are tight. Use a 3/8 in. (1 cm) deep well socket. www.insigniaproducts.com 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

23
www.insigniaproducts.com
NS-FDRE44W1/NS-FDRE44W1-C
INSTALLATION INSTRUCTIONS
4
Connect the other wires to the outer terminal block screws. Make sure that
you cross the screws through the terminal rings, then tighten the screws.
5
Tighten the strain relief screws.
6
Insert the tab on the terminal block cover into your dryer's rear panel slot,
then secure the cover with a screw.
WARNING:
We recommend using ring-type terminals. If you use strap terminals, make
sure that they are tightened.
WARNING:
Risk Of Electric Shock
- All U.S. models are produced for a
3-WIRE SYSTEM
CONNECTION
.
The dryer frame is grounded to the neutral conductor at the terminal block.
A
4-WIRE SYSTEM CONNECTION
is required for new or remodeled
construction, mobile homes, or if local codes do not permit grounding
through neutral conductor.
If the 4-wire system is used, the dryer frame cannot be grounded to the
neutral conductor at the terminal block. See to the “Electric requirements
on page 18
for 3-wire or 4-wire system connections.
Remove the terminal block cover plate. Insert the power cord with a
UL-listed strain relief through the hose provided in the cabinet near the
terminal block. A strain relief must be used. Do not loosen the nuts already
installed on the terminal block. Be sure they are tight. Use a 3/8 in. (1 cm)
deep well socket.