Intel BB5000XALR Specification Update - Page 15
Console Redirection Baud Rate Setting auto changing to 19.2K
![]() |
View all Intel BB5000XALR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Monthly Specification Update Enterprise Platforms and Services Marketing 13. Power supply redundancy state is misleading when only one power supply is installed Problem If a single power supply is installed in a chassis that supports redundant power supplies, the BMC indicates the power supply redundancy state as "redundant". Implication In a single power supply configuration, the redundancy sensor should be ignored. Redundant chassis with fully redundant power supplies accurately reflect the redundancy status. Status This erratum may be fixed in a future firmware revision. Workaround None. 14. Hot-swap Controller (HSC) and Local Control Panel (LCP) updates may take a long time Problem The Hot Swap Controller (HSC) and Intel Local Control Panel (LCP) updates may take a long time. The time to complete each update could exceed 30 minutes. Implication Updating HSC and LCP may take a long time. Status This erratum may be fixed in a future firmware revision. Workaround None. 15. Console Redirection Baud Rate Setting auto changing to 19.2K with Serial Over LAN (SOL) active Problem If configuring a SOL connection, the only baud rate allowed is 19.2K. If any other baud rate is selected, the system will always revert back to 19.2K after the DC cycle. Implication Users will not be able to configure a SOL connection with a different baud rate for their application. Status This erratum is fixed in BIOS release R0045 and later releases. Workaround None. 9
![](/manual_guide/products/intel-bb5000xalr-specification-update-85d4b4f/15.png)