Monthly Specification Update Enterprise Platforms and Services Marketing Workaround If the module is not reset, you can force it to reset by removing and replacing AC power to the system. 39. SAS drive in a ROMB RAID 5 may drop offline during a reboot in the Intel® Server System SR2500PALLX Problem When five or six drives are inserted and SAS ROMB RAID 5 is configured, drives may drop offline during a system reboot in the Intel® Server System SR2500PALLX. Implication This only happens with specific drives. Updating the drive's firmware to the latest version should resolve this issue. Status This erratum is fixed by updating SAS drive firmware. Workaround None. 40. Intel® Server System SR2500ALLX sixth hard drive filler panel is difficult to remove Problem It may be difficult to remove the Intel® Server System SR2500ALLX 6th hard drive filler panel. Implication Certain systems may exhibit this issue. Root cause was found with the manufacturing tooling. Status No fix. Workaround Customers who order ASR2500SIXDRV with MM#885929 (TA# D43807-004) will also get a installation guide. 19