Intel BLKD946GZABL Product Specification - Page 30

Hardware Management Subsystem

Page 30 highlights

Intel Desktop Board D946GZAB Technical Product Specification Table 5. LAN Connector LED States LED LED Color LED State Link Off Green On Blinking Off Data Rate Yellow On Condition LAN link is not established. LAN link is established. LAN activity is occurring 10 Mbits/sec data rate is selected. 100 Mbits/sec data rate is selected. 1.9 Hardware Management Subsystem The hardware management features enable the board to be compatible with the Wired for Management (WfM) specification. The board has several hardware management features, including the following: • Fan monitoring and control • Thermal and voltage monitoring • Chassis intrusion detection 1.9.1 Hardware Monitoring and Fan Control The features of the hardware monitoring and fan control include: • Power supply monitoring of four voltages (+12 V, +3.3 VSB, and +VCCP) to detect levels above or below acceptable values • Thermally monitored closed-loop fan control, for all three fans, that can adjust the fan speed or switch the fans on or off as needed 1.9.2 Fan Monitoring Fan monitoring can be implemented using Intel Desktop Utilities or third-party software. For information about The functions of the fan headers Refer to Section 1.10.2.2, page 35 1.9.3 Chassis Intrusion and Detection The board supports a chassis security feature that detects if the chassis cover is removed. The security feature uses a mechanical switch on the chassis that attaches to the chassis intrusion header. When the chassis cover is removed, the mechanical switch is in the closed position. For information about The location of the chassis intrusion header Refer to Figure 14, page 48 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Intel Desktop Board D946GZAB Technical Product Specification
30
Table 5. LAN Connector LED States
LED
LED Color
LED State
Condition
Off
LAN link is not established.
On
LAN link is established.
Link
Green
Blinking
LAN activity is occurring
Off
10 Mbits/sec data rate is selected.
Data Rate
Yellow
On
100 Mbits/sec data rate is selected.
1.9
Hardware Management Subsystem
The hardware management features enable the board to be compatible with the Wired
for Management (WfM) specification.
The board has several hardware management
features, including the following:
Fan monitoring and control
Thermal and voltage monitoring
Chassis intrusion detection
1.9.1
Hardware Monitoring and Fan Control
The features of the hardware monitoring and fan control include:
Power supply monitoring of four voltages (+12 V, +3.3 VSB, and +VCCP) to detect
levels above or below acceptable values
Thermally monitored closed-loop fan control, for all three fans, that can adjust the
fan speed or switch the fans on or off as needed
1.9.2
Fan Monitoring
Fan monitoring can be implemented using Intel Desktop Utilities or third-party
software.
For information about
Refer to
The functions of the fan headers
Section 1.10.2.2, page 35
1.9.3
Chassis Intrusion and Detection
The board supports a chassis security feature that detects if the chassis cover is
removed.
The security feature uses a mechanical switch on the chassis that attaches
to the chassis intrusion header.
When the chassis cover is removed, the mechanical
switch is in the closed position.
For information about
Refer to
The location of the chassis intrusion header
Figure 14, page 48