Intel SR1530AHLX User Guide - Page 68

Install Drive Carrier into the Server System SR1530AH, SR1530AHLX

Page 68 highlights

11. Set the drive assembly into place in the chassis. See letter "A" in the figure below. 12. Attach the drive assembly to the chassis with the screw that you removed in Step 6. See letter "B" in the figure below. Note: The assembly that contains the optical drive bracket must be installed at the left side of the system. B A HDD 0 HDD 1 AF000667 Figure 37. Install Drive Carrier into the Server System (SR1530AH/ SR1530AHLX) 13. Install the server system cover. For instructions, see "Installing the Server System Cover". 46 Intel® Server System SR1530AH / SR1530AHLX / SR1530HAHLX

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

46
Intel
®
Server System SR1530AH / SR1530AHLX / SR1530HAHLX
11.
Set the drive assembly into place in the chassis. See letter “A” in the figure below.
12.
Attach the drive assembly to the chassis with the screw that you removed in Step 6.
See letter “B” in the figure below.
Note:
The assembly that contains the optical drive bracket must be installed at the left side of the
system.
Figure 37. Install Drive Carrier into the Server System (SR1530AH/
SR1530AHLX)
13.
Install the server system cover. For instructions, see
“Installing the Server System
Cover”
.
AF000667
HDD 0
HDD 1
A
B