Intel SR2520SAXR User Guide - Page 82
Replacing a System Fan
UPC - 735858197335
View all Intel SR2520SAXR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Replacing a System Fan Caution: The system fans are NOT hot swappable. Before removing or replacing a fan, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. Note: The fans that are integrated into the power supply cannot be replaced separately. If one of the fans in the power supply fails, the power supply must be replaced. The system fans at the front of the Intel® Server System SR2520SA can be individually replaced if one of them fails. Use the steps below to replace either a dual rotor fan or a single rotor fan. 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the server system cover. For instructions, see "Removing the System Cover". 4. Disconnect the fan cables from the server board (see letter "A" in the figure below). 5. Remove the four screws securing the fan module to the chassis (see letter "B" in the figure below). Lift straight up to remove the module (see letter "C" in the figure below). B A C AF001462 Figure 50. Removing the Fan Module 6. Remove the two screws from the fan module and remove the failed fan from the module. 60 Intel® Server System SR2520SA User's Guide