Intel SSR212MC2 Hardware Technical Product Specification - Page 42

Environmental Limits

Page 42 highlights

Environmental Limits Intel® Storage Server SSR212MC2 8. Environmental Limits 8.1 System Office Environment Table 20: System Office Environment Summary Parameter Operating Temperature Non-Operating Temperature Non-Operating Humidity Acoustic noise Operating Shock Package Shock Electrostatic Discharge (ESD) System Cooling Requirement in British Thermal Units (BTU) per Hour Limits 10 degrees celcius to +35 degrees celcius with the maximum rate of change not to exceed 10 degrees celcius per hour. -40 degrees celcius to +70 degrees celcius 95%, non-condensing at 35 degrees celcius 7.0 BA (Rackmount) in an active state at typical office ambient temperature. (23 ± degrees celcius) No errors with a half sine wave shock of 2 G (with 11 millisecond duration) Operational after a 24 inch free fall, although cosmetic damage may be present (chassis weight 30 lbs) ±15 Kilovolt (KV) per Intel® Environmental test specification 3600 BTU/hour (at 850W) 8.2 System Environmental Testing The system has been tested per the Intel® Environmental Standards Handbook, Intel document number 662394-03. These tests include: • Temperature Operating and Non-Operating • Humidity Non-Operating • Packaged and Unpackaged Shock • Packaged and Unpackaged Vibration • AC Voltage, Frequency and Source Interrupt • AC Surge • Acoustics • ESD • EMC Radiated Investigation 34 Revision 1.2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Environmental Limits
Intel® Storage Server SSR212MC2
34
Revision 1.2
8.
Environmental Limits
8.1
System Office Environment
Table 20: System Office Environment Summary
Parameter
Limits
Operating Temperature
10
degrees celcius to +35
degrees celcius with the maximum rate of
change not to exceed 10
degrees celcius per hour.
Non-Operating Temperature
-40
degrees celcius to +70
degrees celcius
Non-Operating Humidity
95%, non-condensing at 35
degrees celcius
Acoustic noise
7.0 BA (Rackmount) in an active state at typical office ambient
temperature. (23 ±
degrees celcius)
Operating Shock
No errors with a half sine wave shock of 2 G (with 11 millisecond
duration)
Package Shock
Operational after a 24 inch free fall, although cosmetic damage may be
present (chassis weight 30 lbs)
Electrostatic Discharge (ESD)
±15 Kilovolt (KV) per Intel
®
Environmental test specification
System Cooling Requirement
in British Thermal Units (BTU)
per Hour
3600 BTU/hour (at 850W)
8.2
System Environmental Testing
The system has been tested per the
Intel
®
Environmental Standards Handbook
, Intel document
number 662394-03. These tests include:
Temperature Operating and Non-Operating
Humidity Non-Operating
Packaged and Unpackaged Shock
Packaged and Unpackaged Vibration
AC Voltage, Frequency and Source Interrupt
AC Surge
Acoustics
ESD
EMC Radiated Investigation